NEWS

ASTM E1228-2017 Standard Test Method for Determination of Peroxide-Catalytic Iodometry

Meaning and use 5.1 Peroxy esters are widely used as chemical intermediates, catalysts and initiators. This test method provides a procedure for the determination of peroxy esters to determine whether they are suitable for their intended use. ASTM E1228-2017 Standard Test Method for Determination of Peroxide-Catalytic Iodometry Step 1: Scope 1.1 The test method includes the determination of peroxy esters of organic peroxides. Note 1: Additional test methods for the determination of organic peroxides are given in test methods E298, E475 and E755. 1.2 Review the...

ASTM D871-1996 Standard Test Method for Testing Cellulose Acetate

Meaning and use 4.1 The moisture content of cellulose esters can be used to estimate the dry weight of cellulose esters. Since cellulose esters are desiccants, their moisture content can vary greatly depending on storage. ASTM D871-1996 Standard Test Method for Testing Cellulose Acetate Step 1: Scope 1.1 These test methods include procedures for testing cellulose acetate. 1.2 Test procedures can be found in the following sections: 1.3 Values expressed in SI units shall be considered standard. The values given in parentheses are for reference only. 1.4...

ASTM D914-2012 Standard Test Method for Ethyl Cellulose

Standard No. : ASTM D914-2012 Standard No. : Standard Test method for ethyl cellulose Practice Status: Current Meaning and use 5.1 The results of this test are used to calculate the total solids in the sample, and by conventional use all materials volatilized at this test temperature are referred to as moisture. 5.2 Moisture analysis (together with sulphate ash) is used to calculate the content of active polymers in the material and should be taken into account when determining the content of ethyl...

ASTM D1343-1995 Standard Test Method for Determining the Viscosity of Cellulose Derivatives by the Ball Drop Method

Meaning and use The test provides a simple method for determining the viscosity of cellulose derivatives in a given solvent. The answers are expressed in units commonly used in industrial practice. Such information is required for cellulose derivatives that will be extruded, molded, sprayed or brushed as-is or in solution. Step 1: Scope 1.1 This test method describes the apparatus and general procedure for the measurement of pellet viscosity on solutions of various cellulose derivatives. Sample preparation instructions, solution concentrations, and other details...

Understand the characteristics of the differential thermal analyzer

Differential thermal analyzer is a technique to measure the temperature difference and temperature relationship between a substance and a reference substance under programmed temperature control. The DTA curve describes the temperature (△T) between the sample and the reference material as a function of temperature or time. As a classical thermal analysis method of thermal effect under controlled program temperature, it has been widely used in the research and development, process optimization, quality control and failure analysis of various materials and...

The use of differential thermal analyzer tips together to understand the next

The principle of the differential thermal analyzer is: the sample to be tested and the reference substance (thermal inert substance) are placed in the furnace under the same conditions, and the temperature is heated or cooled at the same speed according to the given program. When the heated sample produces changes in physical and chemical properties at different temperatures (such as phase transformation, crystallization structure transformation, crystallization, boiling, sublimation, gasification, melting, dehydration, decomposition, oxidation, reduction... And other reactions), accompanied by...

High temperature differential thermal analyzer is mainly used in the following fields

High temperature differential thermal analyzer is an important thermal analysis method, which is a test technology to measure the relationship between the temperature difference of a substance and a reference substance and temperature or time under the temperature control program. This method is widely used to determine the characteristic temperature and the heat absorbed or released during the thermal reaction of a substance, including physical or chemical reactions such as phase transformation, decomposition, combination, solidification, dehydration, evaporation, etc. Widely used...

What needs to be done before using a synchronous thermal analyzer

Synchronous thermal analyzer controller, software advantages: 1, the use of imported ARM processor, sampling speed, processing speed is faster. 2. Four-channel sampling AD collects DSC signal, TG signal and temperature T signal. 3, the power supply and water circulation parts are separately controlled by 8bit single-chip microcomputer, so that the host and the cooling part are separated and do not interfere with each other, but the two are closely connected, and the cooling part accepts the control of the host. 4, USB two-way communication...