NEWS

ASTM D1439-2015 Standard Test Method for Sodium Carboxymethyl Cellulose

Meaning and use 5.1 Moisture analysis (as well as purity) is used to calculate the amount of active polymer in the material and needs to be considered when determining the amount of sodium carboxymethyl cellulose for various formulations. Step 1: Scope 1.1 These test methods include tests for sodium carboxymethyl cellulose. 1.2 Test procedures are displayed in the following order: ASTM D1439-2015 Standard Test Method for Sodium Carboxymethyl Cellulose 1.3 Values expressed in SI units shall be considered standard. The values given in parentheses are for...

ASTM D1795-2013 Standard Test Method for the Characteristic Viscosity of Cellulose

Meaning and use 4.1 This test is a sensitive measure for degradation of cellulose resulting from the action of heat, light, acids, bases, oxidants and reducing agents during processing or purification. If desired, the intrinsic viscosity value can be converted to degree of polymerization (DP) or intrinsic fluidity. 4.2 Cellulose solutions are not Newtonian liquids; That is, their viscosity depends on the shear rate or velocity gradient during the measurement. For low molecular weight (DP) samples and low concentration samples, this effect...

ASTM D1926-2011 Standard Test Method for Carboxyl Content of Cellulose

Meaning and use These test methods measure the amount of carboxyl groups present in wood or lint pulp. The carboxyl group represents the surface charge of the pulp, which is a very important amount used in the paper industry. Step 1: Scope 1.1 These test methods include the determination of the carboxyl content or ion exchange capacity of cellulose from any source. Two test methods, sodium chloride-sodium bicarbonate method (1) and methylene blue method (2), are described. Test methods need to be used...

ASTM B697-88-2016 Standard Guide for Selection of Sampling Schemes for Inspection of Electrodeposited Metallic and Inorganic Coatings

ASTM B697 Standard Guidance for Selection of Sampling Protocols for Inspection of Electrodeposited Metallic and Inorganic Coatings provides guidance for selecting a sampling plan for inspection of electrodeposited products and associated coatings to determine whether submitted batches of coated products comply with applicable specifications for coatings. abstraction This guide covers a standard method for selecting a sampling plan for checking the electrodeposition of metallic and inorganic coatings on products, with the aim of determining whether the submitted lot complies with the specifications...

Thermogravimetric analyzer operation method and precautions

What is a thermogravimetric analyzer? For many customers who have never touched this instrument, it may be relatively unfamiliar. However, for some industries engaged in the production of plastics, metals and plastics, the thermogravimetric analyzer is a commonly used testing instrument. It is an instrument that uses thermogravimetric method to measure the relationship between the mass of a substance and the temperature under programmed temperature control. The data measured by experiments are used to study the thermal stability and composition...

Principle and structure of high temperature differential thermal analyzer

Principle and structure of high temperature differential thermal analyzer High temperature differential thermal analyzer is a thermal analytical instrument that tests the thermal effect of substances in the process of heating or cooling, which can study the relationship between the physical and chemical change rate of substances and temperature, as well as the characteristics of some physical and chemical properties of substances under the action of heat. The functional relationship between the temperature difference and the temperature between the substance and...

What does a differential scanning calorimeter measure?

Recently, when many customers consult the differential scanning calorimeter, they will want to know what it can measure. In response to this common problem, Nanjing Exhibition small series to carry out a simple introduction. Before this, we have to have a basic understanding of this instrument, in fact, differential scanning calorimeter is also referred to as DSC, DSC in order to make the sample in a certain temperature program (rise/fall/constant temperature) control, observe the sample end and the reference end...

Do you know how to use a fast heat conductor

Rapid thermal conductivity meter is a new type of thermal conductivity measuring instrument. The advent of the thermal conductivity tester is a major improvement in the testing efficiency of material thermal conductivity. Its test speed and repeatability are the traditional power method, heat flow meter method can not be done, because the test principle of the instrument is only related to the thermal characteristics of the material, and the test only acts on the surface of the material. Therefore, the...