NEWS

ASTM D2574-2016 “Standard Test Method for Resistance to Microbial Attack of Latex Paints in Containers”

Meaning and use 4.1 Spoilage of the paint in the container leads to spoilage, lower pH, gas formation and reduced viscosity. This test method provides a standard procedure for assessing the resistance of latex paints to microbial deterioration. The results should enable: (1) paint manufacturers to select effective preservatives and (2) preservative suppliers to evaluate the performance of competitive and developmental preservative latex paints. 4.2 This test method is better used by personnel who have been trained in basic microbiology. Note 1: The...

ASTM D3273-2016 Standard Test Method for Resistance to Mold Growth on Surfaces of Environmental Indoor Coatings

Meaning and use 3.1 Accelerated tests to determine the resistance of interior coatings to mold growth are helpful in evaluating the performance of coatings designed for interior environments that promote mold growth, as well as to assess the total levels of compounds that may inhibit this growth and their use (see also note 1). 3.2 This test method is better used by personnel who have been trained in basic microbiology. ASTM D3273-2016 Standard Test Method for Resistance to Mold Growth on Surfaces of...

ASTM D3274-2009 Standard Test Method for Evaluating the Degree of Surface Defects in Paint Film for Fungal or algal Growth or Accumulation of Soil and Dirt

Meaning and use 4.1 The fungal growth on and on the surface of the paint film is the main cause of discoloration or deformation of the painted surface. Because of their black pigmentation, it is often difficult to distinguish fungi from dirt or soil particles. 4.2 Use of graphic standards: 4.2.1 The graphical references that are part of this test method are for illustrative purposes and may be used for visual comparison. 4.2.2 The diagram represents the schematic diagram of the various growth levels...

ASTM D3456-2018 “Testing Sensitivity of Paint Film to Microbial Attack by Standard Embodiments of External Exposure Determination”

Meaning and use 4.1 The growth of fungi and algae on and on the surface of the paint film is the main cause of discoloration or deformation of the painted surface. The practice includes the preparation of the coatings used for testing, their application on the substrate, and the placement of the coated plate on the external test fence to determine the extent of microbial attack that may occur on the coated surface over a period of time. This practice is...

How to choose the right thermogravimetric analyzer

Thermogravimetric analyzer (TGA) is a kind of instrument used to detect the relationship between temperature and mass of a substance. Thermogravimetry is to measure the mass of a substance with temperature (or time) under programmed temperature control. When the substance under test sublimates, vaporizes, breaks down gas or loses crystal water during heating, the mass of the substance under test will change. In this case, the thermogravimetric curve is not a straight line but a decline. By analyzing the thermogravimetric curve,...

Differential scanning calorimeter has a wide range of applications

Differential scanning calorimeter, as one of the common coal laboratory equipment - calorimeter series products, occupies an important position in the whole calorimeter family; The principle of differential scanning calorimeter is actually differential scanning calorimetry, and the fields of application of differential scanning Differential scanning calorimeter has a wide range of applications calorimeter are extremely extensive, as follows: 1, stability measurement of the thermal stability of the substance, the determination of antioxidant properties, etc. 2, composition analysis of inorganic substances, organic matter, drugs...

Learn all about fast heat transfer meters

High stability and high precision constant current module is adopted in the host of the rapid thermal conductivity tester. Metal case is computer white, modeling atmosphere, user-friendly operation, compact structure. Color LCD display, touch operation. Mandatory system protection time can greatly extend the service life of equipment. Learn all about fast heat transfer meters Instrument features: 1. Wide test range, stable test performance, in the domestic similar instruments, in the priority level; 2. Direct measurement, test time about 5-160s can be set, can quickly...

The high temperature differential thermal analyzer is composed of a program control component, a furnace body and a recorder

High temperature differential thermal analyzer is mainly composed of temperature control system and differential thermal signal measurement system, supplemented by atmosphere and cooling water channel, measurement results are processed by the recorder or computer data processing system, high temperature differential thermal analyzer is a kind of differential thermal analyzer, using self-developed gas chromatography, mass spectrometry thermostat joint, thermostat belt, thermostat controller: It can fully ensure the secondary detection of tar and various reaction gases. An instrument for measuring the temperature difference...