LS-1006 Portable Contact Angle Tester

  • Description
  • Inquiry

LS-1006 Portable Contact Angle Tester

1· Preface

As is known to all, nanomaterials science and engineering have become the world’s research hotspots. When studying the surface modification of nanomaterials, the concept of wetting contact Angle is often involved.Contact Angle refers to the level of a solid plane drops of a droplet and solid on the surface of the solid – liquid – gas three-phase junction, the gas-liquid interface and the solid-liquid interface two tangent to clamp the liquid phase in the Angle.

The surface can be a measure of the breakdown of chemical bonds between molecules on the surface of the material.In the theory of solid physics, the surface atoms have more energy than the atoms inside the material, and therefore, according to the principle of the lowest energy, the atoms spontaneously tend to the interior rather than the surface.Another definition of surface energy is that the material’s surface is more energy than the interior of the material.

The pull of the interaction of the boundary between the two adjacent parts of the liquid surface perpendicular to their unit length.The formation of surface tension is closely related to the special stress state of the molecules in the thin layer of the liquid surface.The existence of surface tension forms a series of special phenomena observed in daily life.

 

  1. LS-1006 Portable Contact Angle Tester
  2. 2. Instrument application field

S TFT – LCD panel industry: glass panel and the coating quality of cleanliness measurement;TFT printing circuit, color filter, ITO conductor film and other pre-coating quality measurement

S printing, plastic industry, surface cleaning and the adhesion quality measurement;Measurement of ink adhesion;Compatibility measurement of glue colloidal properties;The fastness of the dye

S semiconductor industry: a wafer cleanliness measurement;Control of HMDS;Research of CMP research and measurement, photoresist and imaging agents

S chemical materials research: waterproof and hydrophilic materials research;The surface activity and detergent’s tension and humidity;Adhesion enhancement and adhesion surface can be measured

S IC encapsulation: substrate surface cleanliness;Identification of atomic synthesis;BGA welding surface;The adhesion of epoxide is measured.

 

  1. LS-1006  Portable Contact Angle Tester
  2. 3. Instrument introduction

The instrument adopts the modern manufacturing technology, instrument adopts advanced special CCD digital camera, high resolution zoom microscope with times background and high brightness LED light source system, match 3 d sample sets, workbench can be up and down, left and right sides, front and rear direction.To achieve the micro – sampling and up and down, left and right precision movement.It also designed the telescopic rod structure table, which can adapt to the occasion of increasing the thickness of different user materials.The instrument frame can be adjusted according to the size of the style, and the scope of the instrument can be expanded.The software collocation correction function, the test results can be saved in the same report several times, can let the user better control the material data.The instrument is designed to be beautiful, easy to operate and meet the needs of users.Applicable to all kinds of industry determination of contact Angle users

 

LS-1006 Portable Contact Angle Tester

4. Requirements for improvement of quality control

Optical contact Angle measuring instrument: it is a simple, fast and sensitive method to measure the wettability of solid surface.The surface tension of the solid surface can be measured indirectly.The following is a comparison table of test methods:

Test methodAdvantageshortcoming
Optical contact Angle measuring instrument1. The water drop Angle can be quantifiable and definite

2. Uniformity measurement

3. Small error value

Cost is a little higher
Surface test agentThe cost is lowThe error is large, and the accuracy is affected after multiple tests
Atomic force microscope AFMExtremely small measurements (atomic surface, nanostructure)High cost, small image, slow speed, easy to damage the probe

 

  1. LR-SDP-300  Portable Contact Angle Tester
  2. Product features

S professional high precision injection system, full computer control, droplet control precision can reach 0.05 u l

S small volume, high efficiency, effect, can carry on the automatic measurement of large size glass

S adjustable single wavelength industrial-grade LED light source;The image is clearer;The service life can be up to 15000H

S using high-performance Japan original installation import machine, to ensure the best imaging effect.

S adopting USB2.0 standard interface, data transmission speed, high compatibility

S high intensity aviation aluminum alloy structure, modular design concept, configurable commonly used measurement accessories

S domestic provide the first German imports of contact Angle measurement calibration samples, make sure it is accurate measurement results (optional)

S the most professional contact Angle analysis, contact Angle measurement is more suitable for a variety of materials

S adopts international advanced calculation method, can automatically identify reference line and contour line, no human error

S high-speed automatic measurement, to operate and intuitive read data results

S surface contact Angle analysis module, a more simple operation, more accurate results

S video fast test data, can be continuous changes in the forms of contact Angle test

S export function, multiple data measurement data is a key experiment report is deduced

 

  1. Instrument parameters

S contact Angle measuring range: 0-1800

S contact Angle resolution precision: ±0.01 °

S contact Angle measuring accuracy: ±10

S table interfacial tension measurement range: 0-1000 mn/m;Measurement accuracy: 0.01 mN/m

S surface can calculate: Fowks, OWRK, ZismanPlot, EOS (liquid database software pre-installed in the part, can build a liquid performance parameters)

S high precision automatic drip system: high precision industry trace injection pump;Drip accuracy: 0.1mu l

S contact Angle with high precision instrument calibration tablets: Germany imported from contact Angle calibration standard 3 ° 5 ° 8 ° to 60 °, 90 ° 115 ° 120 ° ellipse

 

7·Contact Angle professional measurement method

  • (sessile drop);
  • (pendant drop);
  • (wetted fiber);
  • (sessle fiber drop);

 

  1. 8. Software overview

S contact Angle diversity analysis methods: full automatic fitting, semi-automatic fitting, manual level measurement, cant manual measuring, wide high measuring method, artificial tangent method, etc., Angle of forward/backward Angle, roll Angle (Angle)

S diversified software calculation method: circle fitting (40 degrees Celsius);Elliptical quasi legal (40-120 degrees);Young-lapalacer intended to be legal (over 120 degrees)

S precision of surface free energy calculation: Fowks method, OWRK method, ZismanPlot, EOS (liquid database software pre-installed in the part, can build a liquid performance parameters)

S software measurement operation: one key, press the blank space key 】 【 opened the camera;Accurate drip;[press 2 key] – high – precision automatic measurement

S irregular product test development: the concave and convex surface testing, surface testing, rolling Angle test, advance Angle back Angle test, high and low temperature contact Angle test

S high-speed photograph way: single/continuous/video;Video of any film export;Video video can be automatically measured (dynamic contact Angle)

S detailed database management: export Excel spreadsheet data word image data;A more intuitive and unrestricted data report

S CCD: SONY original installation import high speed industrial chips;25 frames/S, 60 frames/S, 300 frames/S, 1,000 frames/S

S power supply and power: 220 v / 60 hz

 

  1. 10. Accord with relevant national standards

S GB/T 24368-24368 (glass surface hydrophobic pollutants detection)

S SY/T5153-2007 (reservoir rock wettability determination method)

S ASTM D 724-99 (2003) (the surface wettability of paper test method)

S ASTM D5946-2004 (plastic film and water contact Angle measurement.)

S ISO15989 (plastic film and sheet corona processing thin film of water contact Angle measurement.

Contact Us