Description

Diaper Absorption Performance Tester

Scope of Application

It is used to determine the absorption speed, re-uptake amount and leakage amount of disposable diapers and incontinence pads, etc. for their permeability performance.

Meeting Standards

GB/T 28004.1-2021 Diapers – Part 1: Diapers for Infants

GB/T 28004.2-2021 Diapers – Part 2: Diapers for Adults

Instrument Features

1. Automatically completes liquid adding, constant pressure application, timing and other test processes, and measures key absorption performance indicators of samples such as pressure absorption speed, rewetting volume and leakage volume.

2. Touch screen control with Chinese and English menus, human-machine interaction mode for easy operation.

3. Built-in thermal printer enables on-site quick printing of test results.

4. Professional computer analysis software supports two-way operation with computers.

5. High-precision peristaltic pump ensures the accuracy of penetrating liquid volume.

6. Built-in water tank made of 316L stainless steel, durable and rust-proof; with automatic heating and constant temperature functions.

7. No manual liquid adding required for testing; one-key start realizes automatic liquid adding and testing.

8. Electrodes made of platinum, featuring fast response and long service life.

9. Adopts stepping motor and high-precision ball screw drive for accurate stroke control.

10. Automatic data processing, capable of calculating test average value, standard deviation and coefficient of variation.

11. Equipped with high-precision balance, which directly calculates leakage volume and rewetting volume after weighing.

12. Uses stainless steel weight pressure blocks to provide constant pressure; effectively avoids pressure changes caused by sample water absorption.

13. Equipped with buzzer reminder function.

Diaper Absorption Performance Tester

Technical Specifications

Timing Device Accuracy

0.01s

Liquid Adding Device

Liquid adding volume deviation: ±2mL;

Liquid adding flow rate: 200~800mL/min

Liquid Adding Tank Capacity & Volume

Tank capacity: 2L

Infant Diapers: (40±2)ml/(60±2)ml/(80±2)ml

Infant Diaper Pads: (30±2)ml/(40±2)ml/(50±2)ml

Adult Diapers: (100±2)ml/(150±2)ml

Adult Diaper Pads: (70±2)ml/(100±2)ml

Liquid Adding Flow Rate

Infant: (480±10)ml/min

Adult: (720±15)ml/min

Liquid Adding Pressure

(2.0±0.2)kPa

Compression Pressure

(4.0±0.2)kPa

Balance Accuracy & Range

Accuracy: 0.01g; Range: 300g

Overall Dimensions

820×575×750mm

Weight

62kg

Power Supply

AC220V 50Hz 100W

 

                   Standard Test Liquid Adding Module

Infant

W

(80±1)mm(M1)

(85±1)mm(M2)

(95±1)mm(M3)

L

(100±1)mm(M1)

(108±1)mm(M2)

(125±1)mm(M3)

Adult

W

(70±1)mm(M1)

(95±1)mm(M2)

/

L

(170±1)mm(M1)

(170±1)mm(M2)

/

 

Standard Test Compression Module

Infant

W

(80±1)mm(Y1)

(85±1)mm(Y2)

(95±1)mm(Y3)

L

(100±1)mm(Y1)

(108±1)mm(Y2)

(125±1)mm(Y3)

Adult

W

(70±1)mm(Y1)

(95±1)mm(Y2)

/

L

(170±1)mm(Y1)

(170±1)mm(Y2)

/

 

Sample Base

Infant

U-shaped Sample Base

W

(122±1)mm(B1)

(135±1)mm(B2)

(152±1)mm(B3)

L

(125±1)mm(B1)

(136±1)mm(B2)

(154±1)mm(B3)

Adult

Arc-shaped Sample Base

319mm×200mm