What is the difference between DSC and DTA
DSC: differential scanning calorimeter; DTA: Differential thermal analysis. I think baiDSC (differential scanning calorimetry) is better, can determine the melting point of the substance, specific heat capacity, glass transition temperature, purity, crystallinity isothermal scanning calorimeter – the measurement result is the temperature difference differential scanning calorimeter – the measurement result is the heat flow, quantitative better differential thermal analysis (DTA) is a thermal analysis method to measure the temperature difference and temperature relationship between a sample and a reference substance under the condition of programmed temperature. Differential scanning calorimetry (DSC) is a thermal analysis method to measure the relationship between the power difference and temperature between the input sample and the reference under the condition of programmed temperature. The physical meaning of the two methods is different,DTA can only test the temperature characteristic points such as the phase transition temperature,DSC can not only measure the temperature point of the phase transition, but also measure the heat change during the phase transition. The exothermic peak and endothermic peak on the DTA curve have no definite physical meaning, while the exothermic peak and endothermic peak on the DSC curve represent the heat emitted and absorbed respectively.
What is the difference between DSC and DTA
Analysis of difference between DTA and DSC DTA: differential thermal analysis DSC: differential scanning calorimetry. The principle of the two is basically the same, which is to compare the difference in thermal properties caused by the change of temperature between the substance to be measured and the reference substance. The same material can get the curve with basically the same shape and the same information of the reaction material, but the information recorded by the two in the experiment is different. DTA records the temperature difference between the substance to be measured and the reference substance caused by the change of hot melt caused by the phase transition in the process of heating and cooling at the same rate. Generally, a curve with temperature (time) as the horizontal coordinate and temperature difference as the vertical coordinate is obtained. The DSC experiment also requires the reference substance and the substance to be measured to be heated and cooled at the same rate, but the recorded information is the heat difference between the two samples while maintaining the same temperature. The resulting curve is a curve with temperature (time) as the abscissa and heat difference as the abscissa. In comparison, because the reference substance and the substance to be measured always maintain the same temperature during the experiment of DSC, there is no heat transfer between the two, and the precision is relatively high in quantitative calculation. The peak area of DTA can be converted into heat only if the appropriate reference is used. Furthermore,DSC is suitable for low temperature measurement (below 700 ° C), while DTA is suitable for high temperature measurement (above 700 ° C). Differential thermal analysis (DTA) Basic principles of DTA Differential thermal analysis is a technique for measuring the temperature difference and temperature relationship between a substance and a reference substance under programmed temperature control. The differential thermal analysis curve describes the temperature difference (ΔT) between the sample and the reference material as a function of temperature or time. In DAT tests, the change in sample temperature is due to the endothermic or exothermic effects of the phase transition or reaction. Such as: phase transformation, melting, crystalline structure transformation, boiling, sublimation, evaporation, dehydrogenation, fracture or decomposition reaction, oxidation or reduction reaction, lattice structure destruction and other chemical reactions. In general, phase transformation, dehydrogenation reduction and some decomposition reactions produce endothermic effects; Crystallization, oxidation and some decomposition reactions produce exothermic effects. Principles of differential thermal analysis. The sample and the reference material are respectively put into the crucible and placed in the furnace at a certain rate for programmed temperature to represent their respective temperatures, assuming that the heat capacity Cs and Cr of the sample and the reference material (including containers, thermocouples, etc.) do not change with the temperature. In the 0-a interval,ΔT is generally consistent, forming the baseline of the DTA curve. With the increase of temperature, thermal effects (such as phase transition) occur in the sample, and the temperature difference between the sample and the reference object becomes larger, showing a peak in the DTA curve. Obviously, the greater the temperature difference, the greater the peak, the more times the sample changes, the number of peaks is also more, so the number, shape and position of various endothermic and exothermic peaks and the corresponding temperature can be used to qualitatively identify the substance under study, and the peak area is related to the change of heat