LS-209-2 Two Box Thermal Shock Chamber
Product name | Two van hot and cold impact testing machine Use of low temperature and high temperature hot and cold storage tank, in accordance with the cylinder, the hanging basket in turn to high temperature and low temperature box, so as to achieve rapid temperature shock effect, balance (BTC) + special temperature control system design of supply air circulation system, to control SSR P.I.D. way, make the system of heat equal to the amount of heat loss, thus the use of long-term stability. | ||||
Product model | TSD – 11 – NS – 2 p (air-cooled type) บันทึก: air-cooled type need not install cooling towers, water cooled type to install, depends on customer’s requirement. | ||||
Limit sample | The test equipment prohibited: (1)Which is inflammable, explosive, easy to volatile substances sample test or store | ||||
ปริมาณ, size and weight | |||||
Nominal content product | 52ล | ||||
Shopping basket size | W50*H32*D32cm | ||||
Installation dimensions | W132*H187*D155CM | ||||
น้ำหนัก | About 400㎏ | ||||
LS-209-2 Two Box Thermal Shock Chamber ผลงาน | |||||
Test environment conditions | Environment temperature is 25 ℃, ความชื้นสัมพัทธ์ของ 85% or less, test under the condition of no sample in the box GB / T 5170.2 1996 temperature testing equipment. | ||||
High greenhouse | +60℃→+150℃ | ||||
Time | +60℃→+150℃ ≤25min | ||||
ช่วงอุณหภูมิ | -55℃~-10℃ | ||||
Time | +20℃ → -55℃≤60min | ||||
Test (style) | Test chamber upside for high temperature, lower for the low temperature zone, specimen is placed in the basket, basket turns in the high temperature box and low temperature in experiment | ||||
Shock temperature range | (+60~+100)℃/(-40~-10)℃ | ||||
Temperature fluctuation degree | ±0.5℃ | ||||
The temperature deviation | ±2.0℃ | ||||
The temperature recovery time | ≤5min | ||||
Temperature conversion time | ≤10sec | ||||
Restore conditions | High temperature exposure: + 150 ℃ / นาที – > low temperature exposure: 30 ถึง 55 ℃ / 30 นาที Sample maximum weight: 2.5 กิโลกรัม | ||||
Meet the test standard | GB / T 2423.1 2008 ทดสอบ: A test method at low temperature GB / T 2423.2 2008 test B: high temperature experiment method GB/T2423.22-2002 test N: temperature change test method test Na GJB 150.5 ก – 2009 military equipment laboratory test method for part 5: the temperature impact test GJB 360 NS – 1996 temperature impact test GJB367.2-2001 military communication equipment general specification temperature impact test ไออีซี 68-2-14 test method for N: temperature changes | ||||
Structural features |