LS-509-1 Big Color Matching Cabinet

  • Descriere
  • Anchetă

LS-509-1 Big Color Matching Cabinet

Utilizări:

Color matching cabinet is an equipment designed for the visual evaluation of shade and color differences under standardized and controlled lighting conditions. Multiple light sources provide an essential tool for visual color assessment, comparison of color variation, and detection of metamerism (when color samples appear to match under one lighting condition but distinctly change when viewed under a different lighting condition).

LS-509-1 Big Color Matching Cabinet

Specificații:

Dimensiunea interioara:1280*590*600mm
Mărimea afară:1310*620*800mm 95KG
Pack size:1380*700*260mm/1310*690*95mm
Wooden shelf size:1450*700*400mm

Instructions for Llight Source

Name kelvin watt Lamp Type Uses

D65 6500K 2×36W Fluorescent International Standard

Artificial Daylight Artificial Daylight

PHILIPS 36W/965

TL84 4000K 2×36W Fluorescent European,Japan

PHILIPS TLD 36W/840 Shop light Source

CWF 4200K 2×36W Fluorescent Cool White Fluorescent

PHILIPS TLD 36w/33 USA Shop Light Source

COOL WHITE

F 2700K 6×40W Incandescent Sun-settting Light

E27 Yellow Light Source

UV / 1×40W Fluorescent Ultraviolet Lamp

F40T/BLB

BLACK LIGHT

U30 3000K 2Pcs×36W Fluorescent Others USA Shop

PHILIPS TL`D 36W/830 Light Source

Instructions for Lamp Cabinet

  • Provide several light sources,adică. D65, TL84, CWF, UV, F/A
  • Apply microcomputer to switch between the light sources quickly.
  • Super timing function to record use time of each light source separately.
  • All fittings are impored, ensuring quality.
Eu. Descriptions

Cabinet de evaluare a culorii,suitable for all industries and applications where there is a need to maintain color consistency and quality-e.g. Automotive,Ceramics, Cosmetics, Foodstuffs,Footwear, Furniture, knitwear, Leather, Ophthalmic, Dyeing, Ambalare, Printing, Inks and Textile.

Since different light source has different radiant energy,when they arrive on the surface of an article,different colors display.With regard to color management in industrial production,when a checker has compared the color consistence between products and examples, but there may exist difference between light source used here and light source applied by the client.In such condition, color under different light source differs. It always brings following issues: Client makes complaint for color difference even requires for rejection of goods, seriously damaging company credit.

To resolve the above problem,the most effective way is to check good color under same light source .For example,international Practice applies Artificial Daylight D65 as standard light source for checking goods color.

It`s very important to use standard light source to chenk color difference in night duty.

Besides D65 light source ,TL84,CWF, UV, and F/A light sources are available in this Lamp Cabinet for metamerism effect.

  1. Lamp Cabinet Performance
    1. Hepachromic artificial daylight acknowledged by CIE, 6500K color temperature.
    2. Lighting scope: 750-3200 Luxes.
    3. Background color of light source is Neutral Grey of absorbance.In using lamp cabinet, prevent outer light from projecting on article to be checked. Don`t place any unconcerned articles in the cabinet.
    4. Making metamerism test.Through microcomputer, the cabinet can switch between different light sources in very short time to check color difference of goods under different light source. When lighting up, Prevent lamp from flashing as home fluorescent lamp is lighted.
    5. Correctly record use time of each lamp group. Especially D65 standar dlamp shall be replaced after being used for over 2,000 hrs, avoiding error resulted from aged lamp.
    6. UV light source for checking articles containing fluorescent or whitening dye, or be used to add UV to D65 light source.
    7. Shop light source. Oversea clients often require other light source for color check. De exemplu, USA clients like CWF and European and Japan clients for TL84. It`s because that goods is sold indoor and is under shop light source but not outer sun light. It`s become more and more popular to use shop light source for checking color.

 

LS-509-1 Big Color Matching Cabinet

III. Operation Instructions

  1. plug one end of power line into socket at the backside of the lamp cabinet and the other end into electric supply source (electric supply must comply with nominal electricity of the cabinet.) At this time, the display will give information indicating that power is on.
  2. Press “ON/OFF” key for one time and the Timing will display the total service time of this lamp cabinet.
  3. Press D65 key again and D65 lamp lit up. The Timing will display the total service time of D65 lamp. In case of pressing F, TL84, or UV key, the corresponding lamp group lit up. And the Timing will display the total service time of this lamp group. In case of using two or more light sources, it`s just to press two key or more keys.
  4. Put articles to be checked at the center of the bottom of the lamp cabinet.When comparing the color of two or more articles, don`t observe them by overlapping, but to put them in the cabinet parallel.
  5. It`s approprate to observe target in reference to Figure I.When light is projecting on article in right angle, checker shall observe the article in 45° angle.
  6. After working, press ON/OFF key to power-off. Power-off lamp cabinet in case of long-time not use.
  7. Install new lamp in reference to Figure II or instructions noted on the bottom of lamp. Don`t make mistake in positioning lamp. After replacing, zero the use time of new lamp (calculate time from zero) după cum urmează: light up new lamp, extend small screw driver to the central hole of CLR and press the key (the timing of lamps not lit up are not zeroed). Tensiune de intrare: Don`t press CLR key in case of not replacing lamp, avoiding error zeroing.

. Electrical Parameters

fie baterie reîncărcabilă sau alcalină:AC 220V, 50Tensiune de intrare

Putere:less than 300W

Ⅴ.Lamp Cabinet Maintenance

  1. Warranty period of lamp cabinet is one year (person`s careless damage or lamp aging is not in this scope).
  2. Replace it in case the internal wall of lamp cabinet is dirties. Replace it in case lamp works over-normal time or its ends are balckened. We can provide various standard fittings all the time (note:Fitting shall comply with relevant standard).

Contactează-ne