Description

Specific Surface Area and Pore Size Analyzer

Product introduction

The specific surface area and aperture analyzers produce specific surface area and porosity results quickly and reliably, and the analysis station and degassing station are independent and integrated, saving laboratory space. LS-S450 series is one of the indispensable tools in material research and quality control with low operating cost, fast analysis speed, simple use and good reliability.

1.A highly stable gas physical adsorptionanalysis system with 3 analysis stations.

2.PFC high-precision injection and exhaust control system to achieve  1-100%  pressurization  or fixed injection  automatic  control, prevent excessive injection and inlet and exhaust, and minimize analysis time.

3.Three independently controlled and operating  analysis stations. The BET specific surface area analysis time of three samples at 5 points was less than 30 minutes.Software allows users to control and fine-tune analysis speed and precision.

4.Three preparation stations, independently controlled and operated. AI intelligent control system and sample dedicated degassing mode, to achieve a successful preparation, and intelligent monitoring and recording of degassing dehydration.

5.Independent Po test station is standard for continuous measurement of saturated vapor pressure. Saturation vapor pressure can also be entered manually or collected during testing.

6.Large capacity stainless steel dewar bottle provides continuous temperature control for 40h.

7.The metal composite heating furnace achieves a long-term constant temperature of up to 400℃.

Product Advantages

The LS-S450 series of specific surface area and aperture analyzers produce specific surface area and porosity results quickly and reliably, and the analysis station and degassing station are independent and integrated, saving laboratory space.It is one of the indispensable tools in material research and quality control with low operating cost, fast analysis speed, simple use and good reliability.

2.1 Intelligent Degassing System

Integrated intelligent degassing system,3-station AI intelligent degassing station, equipped with independent vacuum system, degassing station and analysis station  can run synchronously and asynchronously to improve work efficiency. Provide “standard”,”ultra- light”,”multi-water” and other modes of one-click selection, intelligent judgment of the treatment effect.

2.2 Fixed Pointand Constant Pressure Test

Arbitrarily set the test pressure range and the number of data points in the test range to shorten the test time. Freely set any P/Po test point, greatly improve data stability.

2.3 Exclusive Test Template Setting

In addition to the standard analysis mode of the software, users can customize the test template according to the sample type and call it with one click. It also supports automatic retrieval of analysis parameters from test reports.

Specific Surface Area and Pore Size Analyzer

Product Parameter

Testing

Principles

Static capacity method.

Precision

Specific  surface  area/pore  size/pore  volume/adsorption   capacity repeatability ≤ 1%.

Adsorbate

77K nitrogen, 87K argon, 273K carbon dioxide, 298K carbon dioxide, etc.

Test Range

Specific surface area ≥ 0.01m2/g (nitrogen),pore size analysis 0.35nm-500nm.

Analysis Station

3 parallel

 

 

AI

Preparation

Station

Same analysis station integrated machine design, independent of each other; Equipped with a heating furnace, with an upper temperature limit  of 450 ℃ and a temperature control accuracy of ± 0.01 ℃ . Equipped with an independent mechanical pump and pressure sensor.

One click selection of multi water and ultra light sample degassing schemes; Multiple intelligent degassing solutions: temperature+fixed time;    Temperature+AI judgment; Temperature+fixed time+AI judgment.

Vacuum System

The analysis station is equipped with a two-stage rotary vane vacuum pump; The preparation station is equipped with a two-stage rotary vane vacuum pump.

Po Testing Station

Independent saturation steam pressure testing station for real-time testing, equipped with independent sensors.

 

Specifications

Power  Supply

Voltage: 220V Power: 700W Frequency: 50 Hz.

Humidity

Relative humidity range from 10% to 90%.

Temperature

-Stable between 20 ℃ and 50 ℃ .

Dewar Flask

 

Configure 1 stainless steel Dewar bottle.

Heating Furnace

 

Isothermal heating furnace, temperature 450 ℃ .

Pressure Sensor

3 analysis stations, 1 Po station, 1000torr.

 

Test

Function

Gas adsorption and desorption isotherms,BET/Langmuir specific surface area,t-plot inner and outer surface area of carbon black, t – plot micropore area/volume, BJH mesoporous pore size/pore area, as mesoporous volume, HK/SF/MP micropores, average pore size, total pore volume analysis, etc.

Intelligent Software

Intelligent software self inspection and warning, can set P/Po start and  end  points,  and  collect  quantity;  One  click  calling  template, supporting custom exclusive templates.

Control System

Intelligent touch system, multi-mode one click selection.