Description

Programmable Thermal Shock Test Chamber

Main Functions:

This series of products is suitable for testing various performance indicators and quality management of aerospace products, information and electronic instruments and meters, materials, electrical engineering, vehicles, metals, electronic products, various electronic components, wires, and cables in high and low rapid alternating environments.

Programmable Thermal Shock Test Chamber

Performance indicators and system components:

Item Description
Product Name Thermal shock test chamber
Model LS-K191
Sample Limit This test equipment is prohibited from testing samples with flammable, explosive, or volatile substances; testing samples with corrosive substances; testing samples with biological substances; testing samples with strong electromagnetic radiation sources; and storing samples with strong electromagnetic radiation sources.
Volume, weight and dimensions
Nominal internal volume 50 L
Effective inner box dimensions W350*H400*D400 (mm)
External dimensions Approximately W1350*H1720*D1600 (mm)
Weight 550 kg
Power supply voltage and power
Maximum power 22.5KW
Maximum current 45A
Power supply conditions and power supply AC 380V three-phase R, S, T, N + protective ground

Voltage fluctuation range: 10%

Frequency fluctuation range: (50 ± 0.5) Hz

TN-S or TT power supply

Protective ground wire resistance less than 4Ω

The user is required to configure an air or power switch of appropriate capacity for the device at the installation site, and this switch must independently control the operation of this device.

Performance indicators
Functional requirements 1. (Air) Cooling and heating indoor spaces;

2. Based on the set temperature, the indoor space reaches the set temperature.

3. Divided into three areas: heat storage area, cold storage area, and test area.

4. The three areas are independent, with temperature control via dampers.

Environmental conditions Ambient temperature: 0~+35℃, relative humidity ≤85%
Meet the test standard test method GJB150.5A-2009 Temperature Shock Test

GB/2423.13-2002 Temperature Shock Test

GJB360B-2009 Temperature Shock Test

GB2423.1-2008/IEC6008-2-1-2007 Environmental Testing for Electric and Electronic Products – Part 2: Test Methods – Test A: Low Temperature

GBT 2423.2-2008 Environmental Testing for Electric and Electronic Products – Part 2: Test Methods – Test B: High Temperature

GBT 10589-2008 Technical Specifications for Low-Temperature Test Chambers

GBT 11158-2008 Technical Specifications for High-Temperature Test Chambers

Temperature range
Temperature range High temperature range: RT to 170°C

Low temperature range: RT to -60°C

Test temperature range: -40°C to 150°C

Temperature shock range High temperature: 60℃~150℃

Low temperature: -10℃~-40℃

Normal temperature: indoor temperature

Control accuracy Resolution accuracy: 0.1°C

Temperature fluctuation: ±1°C

Distribution uniformity: ±2.0°C

Temperature deviation: ±1°C

Heating and cooling rate Heat storage area heating time: From room temperature to 170°C, approximately 30 minutes;

Cooling area cooling time: From room temperature to -60°C, approximately 50 minutes

Temperature recovery time Test area temperature recovery time: 5 minutes.

Impact process (as shown in the figure)

Green is the heat storage curve in the high temperature area, red is the impact curve in the experimental area, and blue is the cold storage curve in the low temperature area.

 
Note: The above performance indicators are measured at an ambient temperature of +25°C, relative humidity ≤85%, and without a sample.
Structural characteristics
Cabinet structure Inner box material: 304# stainless steel, 1.0mm thick

Outer box material: Cold plate, painted, 1.2mm thick

Insulation material: Polyurethane foam + glass fiber, 100mm thick

Door Single door explosion-proof handle
Air conditioning duct Built-in high temperature zone, low temperature zone air room, circulating air duct and stainless steel circulating fan. Through the switching of the damper, heat and cold are evenly blown out from the inside of the air duct, and the temperature stored in the high temperature tank and low temperature tank is dissipated to the test space, thereby achieving rapid temperature alternation and uniform indoor temperature distribution.
Test lead hole A 50mm Φ test hole is drilled and fitted with appropriate insulation components and a dedicated sealing plug.
Control panel Taiwan U-Yi LCD touchscreen programmable controller.

Main power switch, operation indicator, abnormality indicator, end indicator, defrost indicator, power indicator, and RS-232 communication interface.

Low-temperature mechanical room Evaporator, circulating fan, drain, cold storage fins, heater, circulating fan impeller, volute
High-temperature mechanical room Heater, circulating fan, hot storage fins, pressure equalization port, circulating fan impeller, volute
Power distribution control cabinet Main power circuit breaker, controller, distribution board, cooling fan, over-temperature protector, cylinder, pressure protector, liquid storage tank, water-cooled condenser, and refrigeration unit.
Heating system P.I.D.-type heat pipes are used to control heating and achieve temperature balance.
Cooling system (Optional) Use domestic high-quality cooling water tower,
Cooling water tower Water circulation heat dissipation, flow rate 8 tons/hour
Transportation method Complete machine transportation
Test material rack 2 pieces of stainless steel SUS #304 grid-type storage racks (load-bearing capacity ≤ 20kg/piece)
How it works The pre-cooling area, pre-heating area and test area are independent of each other. The three boxes can be switched through the air door without moving the test product. When the room temperature is impacted, the ambient temperature is introduced into the test space through the blower to remove the heat or cold in the test space. At the same time, the air doors of the high and low temperature slots are closed. When the low temperature is impacted, the air doors of the high and normal temperature slots are closed, and the low temperature slot is connected to the test box, and the pre-stored cold energy is instantly introduced into the test box. When the high temperature is impacted, the air doors of the low and normal temperature slots are closed, and the high temperature slot is connected to the test box, and the pre-stored heat is instantly introduced into the test box. Thus, the purpose of rapid temperature alternation is achieved.
Electrical control system
 

Controller

Taiwan Youyi controller, temperature control
Screen display function Adopts a human-machine interactive mode with touch-screen input and control.

Directly displays the setpoint (SV) and actual (PV) temperature values.

Displays the program number, step, remaining time, number of cycles, and operating time.

Displays the program status.

Language switchable between Traditional Chinese and English.

7-inch color LCD display

Program capacity and control functions Program capacity: Up to 120 sets, with program links.

Command re-execution capability: Each command can be executed up to 9999 times.

High temperature start/low temperature start/normal temperature start; two-zone or three-zone shock functions.

Preheat and precool functions.

Skip and hold functions during program execution.

Six PID parameter settings.

Power-off program memory, automatic restart and continued program execution upon power-on.

Temperature wait timer function.

Data acquisition, export, and graph viewing functions.

Scheduled start and shutdown functions.

Date and time adjustment functions.

Key and screen lock (LOCK) function.

Automatic cycle shock or manual selective shock.

Fault history display.

Display backlight adjustment and configurable backlight timer.

PID automatic calculation and fuzzy control.

RS-232 communication interface Can display curves and acquire data

Can be used as a monitoring and remote control system

USB flash drive Configurable 2-32GB memory card, capable of recording test data for two years (self-provided).
Operation mode Program loop mode
Setting range Adjustable according to the device’s operating temperature range (upper limit +5°C, lower limit -5°C)
Display resolution Temperature: 0.1°C; Time: 0.1 min;
Input Thermocouple
Circulation fan Low-noise multi-blade long-axis motor
Heater Imported nickel-chromium alloy electric heater. Heater control method: Contactless equicyclic pulse width modulation, SSR (solid-state relay)
Control method Anti-integral windup PID

BTC balanced temperature control method (temperature test equipment)

Additional functions (standard configuration) Fault alarm, cause, and action prompts

Power-off protection

Upper and lower temperature limit protection

Self-diagnosis and automatic shutdown

Software environment IBM PC compatible computer, CPU PⅡ or above, memory 128MB or above, Simplified Chinese Windows 2000 or Simplified Chinese Windows XP operating system
Temperature measurement T-type thermocouple
Refrigeration system
 

Refrigeration method

In order to ensure the cooling rate and minimum temperature requirements of the laboratory, this laboratory adopts a binary compound refrigeration system. The compound system includes a high-temperature refrigeration cycle and a low-temperature refrigeration cycle. Heat exchange is achieved through an evaporative condenser.
Refrigeration compressor Imported low-temperature compressor – France Taikang 6P*2 units
Cooling method 1. Air Cooling – Optional for indoor ambient temperature control below 35°C

2. Water Cooling – Optional for indoor ambient temperature control above 35°C

Water Cooling: Water-cooled shell and tube condenser, cooling tower heat dissipation

Evaporator Fin-tube heat exchanger
Evaporator condenser Using high-temperature copper brazing, the plate-type heat exchanger features a small surface area, minimal energy loss, and high heat transfer efficiency.
Throttling device Thermostatic expansion valve, capillary tube
Oil separator Separate the refrigeration oil droplets mixed with the high-temperature and high-pressure refrigerant gas discharged from the compressor and return them to the compressor curved track cavity for compressor lubrication and cooling
filter drier Absorbs residual moisture and acidic substances in the refrigerant of the refrigeration system, and filters out solid impurities, copper shavings, etc. in the system, protecting the normal operation of the expansion valve and capillary tube to avoid ice blockage and dirt blockage.
refrigerant Environmentally friendly refrigerant R404A/R23 is used as the refrigeration medium of this refrigeration system
Safety protection device
 

Refrigeration system

Compressor overheat, compressor overcurrent, compressor overpressure, condenser fan overheat
 

test chamber

Adjustable over-temperature protection; Air conditioning duct over-temperature limit; Fan and motor overheat relay
 

other

Main power phase sequence and phase loss protection

Leakage protection

Overload and short circuit protection

Ambient temperature overload protection

Conditions of Use
The user shall guarantee the following conditions:
Environmental conditions Storage environment requirements The equipment environment temperature should be maintained within 0°C to +35°C. Relative humidity: ≤85%
Environmental conditions Storage environment requirements The equipment ambient temperature should be maintained between 0°C and +45°C. When the ambient temperature is below 0°C (when the equipment is stopped for an extended period), drain any remaining water from the equipment to prevent freezing and damage to the pipes.
 

Installation site requirements

1. Please confirm the required dimensions for the equipment installation location.

2. The left and right side panels and rear wall of the test chamber must be at least 500mm away from the wall, and the front must be at least 1000mm away from the wall.

3. During equipment transportation, ensure access to doors, passageways, elevators, etc. to avoid impacting your project progress.

4. Water supply, drainage, electricity, and customer-provided air source (8 kg).

5. Water tower installation distance: It is recommended to be within 20 meters of the machine (any distance beyond this must be specified in advance). The installation must be in a clean, open area free of leaves and debris, with a flat surface. The diameter must be at least 2 meters. There must be no obstructions around the water tower.

 

Main accessories

No. Name
1 Compressors (2 units)
2 Controller
3 Contactor
4 Sensor
5 Dryer
6 High-pressure protector
7 Solenoid valve
8 Oil separator
9 Circulating fan motor
10 Heater (Nichrome)
11 Heat exchanger
12 Evaporator
13 Circulating impeller
14 Shock-proof hose
15 Solid-state relay
16 Condenser
17 Refrigerant
18 Mixed refrigerant
19 Thermal relay
20 AC contactor
21 Water bubbler
22 Plate heat exchanger
23 Mini relay
24 Filter drier
25 Cooling water tower