Description

  1. Product Introduction

The LS-1452G atomic absorption spectrophotometer uses deuterium lamp background technology to provide a reliable guarantee for quantitative analysis of elements. The multi-function window design with single interface reduces the difficulty of the analyst. The graphite furnace adopts the domestic advanced GFTV visual system to realize automatic sampling.

 

Atomic Absorption Spectrometer

II.Application field

Widely used in geology, metallurgy, medicine, chemical industry, petroleum, agriculture, animal husbandry, cement, printed circuit board, environmental protection, commodity inspection and other industries.

 

III.performance characteristics

◆ Four lights, six lights, eight lights optional (optional high-performance element lights), automatic three-dimensional switching, energy balance, multi-lamp preheating at the same time to save waiting time, with deuterium lamp background and self-priming button background function;

◆ Unique integrated design of flame atomizer and graphite furnace atomizer, automatic switching and manual switching dual mode;

◆ Instrument setting conditions automatically optimize memory function, one-key scan peak search, energy balance;

◆ Data report multi-format saving and printing output, convenient data query and comparison;

◆ The instrument software adopts single-interface multi-function window design, which makes the operation simpler, real-time monitoring data changes, supports mainstream Windows operating system, supports remote control and calibration, Chinese/English version is optional, and has comprehensive quality control (QC) function;

◆ Advanced and reliable multiple safety protection system, automatic detection, alarm, such as insufficient pressure, leakage, flameout and other abnormal conditions;

◆ Domestic advanced graphite furnace GFTV visual system, CCD camera real-time monitoring of graphite furnace atomizer, extend the service life of graphite tube;

◆ Automatic sampler system can be realized, automatic configuration of standard curve, automatic dilution, high-precision sampling;

◆ Extendable: hydride system and combined function.

Atomic Absorption Spectrometer

Ⅴ.Technical parameter

Optical system
Wavelength range 185nm-900nm
monochromator Czerny-Turner reinforcement
Grating engraving density 1800pieces /mm
Spectral bandwidth Automatic switching of 0nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm
Wavelength accuracy ≤±0.1nm
Wavelength repeatability ≤±0.025nm
Baseline drift 0.003ABS/30min (static) 0.005ABS/15min (dynamic)
Resolving power

 

 

Copper lamp 324.7nm wavelength, 0.2nm bandwidth, half width 0.2nm±±0.01nm
detector Japan Hamamatsu photomultiplier tube
Element lamp stand Turret type automatic switching light frame
Flame atomization system
Detection limit (Cu)0.006μg/mL
burner 0.5mm×100mm all-titanium burner
repeatability

 

 

RSD≤0.7%
atomizer Metal sleeve high efficiency glass sprayer
Atomizing chamber Corrosion-resistant all-plastic atomization chamber
Safety measure With a variety of automatic safety protection functions
Position adjustment The optimal height and position of flame burner are automatically set
Graphite furnace atomization system
Detection limit (Cd) 1.5pg
Precision  ≤3%
Heating temperature range Room temperature ~3000℃
Heating and temperature control mode The power control mode in drying ashing stage and the optical maximum power mode in atomization stage are adopted
Temperature control accuracy 1%
Heating rate 2000℃/秒
Heating condition setting 11 steps, ramp heating, ladder heating, maximum power heating, temperature monitoring and reverse measurement system
Security protection Pressure system, cooling system fault protection, power monitoring
Background correction
Deuterium lamp background correction ≥60 times at 1ABS
Self-priming background correction  ≥60 times at 1ABS
Data processing
Measurement method Air-acetylene flame process, graphite furnace process
Data processing The linear regression method automatically fits the working curve and calculates the result automatically
Number of repeated measurements 1 ~ 99 times, repeated measurement to calculate the average, automatically give the standard deviation and relative standard deviation
Result output Multi-format data saving and printing
Communication interface Standard RS232, USB expansion interface
Automatic sampler system Optional 85-bit automatic sampler. Automatic configuration of standard curve, automatic dilution, high-precision sampling
Visualization system Optional GFTV video system, graphite furnace video acquisition system
Function expansion Hydride system