JP1204 Series Electronic Analytical Weighing Scale Tester

JP1204 Series Electronic Analytical Weighing Scale Tester

Categories:

  • Description
  • Inquiry

JP1204 Series Electronic Analytical Weighing Scale Tester

Description

 with unique patent super single sensor technology, ensure the accuracy of weighing results, the stability and fast response

 

 membrane weighing technology, instant you trace weighing conditions can also obtain the same speed

 

 unique temperature compensation scheme

 

The unique temperature compensation scheme solves the problem of reliability of balance weighing results due to the influence of temperature

 

 the VA display, operation is simple, clear reading and directly

 

Intuitive and clear VA display, the user’s operation interface is simple, clear structure

 

 adopts isoCAL automatic internal calibration and adjustment function, fully ensure the accuracy of weighing results

 

Fully automatic temperature and time triggered calibration and adjustment functions ensure that accurate weighing results can be obtained at any time and temperature.

 

 unique membrane weighing technology

 

With the unique filtration membrane weighing technology, accurate results can be obtained quickly, even with the minimum sensible load

 

 level 4 shock technology easily meet your all kinds of weighing the environment

 

You can set different environment parameters based on different weighing environments to achieve accurate and fast weighing in corresponding environments

 

 standard communication interface:

 

Automatic identification printer

 

Standard RS232, easy to achieve and peripheral connection

 
JP1204 Series Electronic Analytical Weighing Scale Tester
Parameters
ModelJP1204JP2204JP1204AJP2204A
maximum range(Max)120g220g120g220g
division value(d)0.1mg
Repeatability (typical error)

 

(5% load)

0.2mg
Repeatability (typical error)

 

(Close to 100% load)

0.3mg
Linear error

 

(Typical error)

0.3mg
CalibrationExternal weight calibrationFully automatic internal calibration
sensitivity drift

(+10℃~+30℃)

5ppm/k
operating temperature range (OTR)10℃~30℃
Operating humidity range20%-85% Relative (non-condensing)
Typical stability time3 second
Pan sizeΦ90mm
boundary dimension210mm×310mm×315mm
Height of weighing room210mm
Temperature compensating fluctuation≤1℃/time
working power supply100V -240VAC  frequency 50/60HZ;electricity :MAX0.45A
Baud rate300、600、1200、2400、4800、9600
expertise ratingⅠ level

Contact Us