CHNS Elemental Analyzer 

LS-B18 Elemental Analyzer is a high-end laborator precision analyzer for the analysis of the main elements of organic materials. It realizes rapid and accurate quantitative  analysis and determination of five elements C,H, N,S and O in solid/liquid samples on one instrument, which plays an important role in the study of elemental composition of organic materials and organic compounds. It can be widely used in the fields of scientific research, agriculture, food, petrochemical, chemical industry, geology and mining, pharmaceuticals and so on.

Description

CHNS Elemental Analyzer 

Introduction:

LS-B18 Elemental Analyzer is a high-end laborator precision analyzer for the analysis of the main elements of organic materials. It realizes rapid and accurate quantitative  analysis and determination of five elements C,H, N,S and O in solid/liquid samples on one instrument, which plays an important role in the study of elemental composition of organic materials and organic compounds. It can be widely used in the fields of scientific research, agriculture, food, petrochemical, chemical industry, geology and mining, pharmaceuticals and so on.

Measuring the content of carbon, hydrogen, oxygen, nitrogen and sulfur elements in a sample to reveal the composition, properties and changes of compounds is an effective means of scientific research.

This product is the research and development achievement of LONROY, which undertakes the scientific research project of Shandong Province’s major science and technology innovation project. It has successfully passed the project acceptance of Shandong Provincial Science and Technology Department and has been highly evaluated by industry experts.

Instrument Features:

1. The use of sample – ash high-temperature in-situ position change technology, do not need to clean up the sample residual ash in the combustion tube, the apparent Improve the efficiency and accuracy of the instrument.

Sample-ash high-temperature in-situ exchange technique, using a crucible to contain the sample, which is placed in a combustion/cleavage tube and reversed. It should not only solve the problem of frequent  downtime of traditional instruments to manually remove the ash, and a large number of samples can not be continuously fed, but also avoid the interference of residual ash in the sample to be tested, to ensure   that the sample is fully combusted,  which significantly improves the detection efficiency and accuracy of the test.

The autosample is equipped with a 120-position rotating sample tray for easy sample loading and clear visualization of the crucible arrangement.

Ceramic crucible is resistant to high temperature and oxidation, high strength and no pollution, the crucible can be reused after cleaning after testing.

 

2.High-temperature aluminum silicate fiber combustion furnace, the use of combustion\cracking process  of the temperature field and the carrier gas flow field of the coupling control technology, significantly   improve the working temperature, temperature field uniformity and stability.

The maximum working temperature can reach 1400℃; the length of the stable temperature zone ≥ 200mm; the temperature uniformity deviation of each point within the length of the stable temperature zone  ≤ ± 10  ℃, to achieve  effective control of the uniformity and stability of the temperature field.

3.Aiming at the technical difficulty of low detection accuracy of trace element

samples, develop specific adsorption and desorption technology to significantly improve the detection accuracy of the instrument.

Based on the characteristics of CO2, H2O and SO2,  which are the products of combustion of organic  elements, we have developed special molecular sieve materials for specific adsorption and desorption, and three types of adsorption columns are used for the specific physical adsorption of H2O, SO2, and CO2 in that order.

When the analysis of one element is completed, the next gas component is released for detection according to the programmed temperature rise, realizing efficient adsorption and desorption of the gas mixture to be tested. During the detection  process,  adsorption is complete, desorption is rapid, gas  separation efficiency is high, separation is complete,  effectively avoiding the peak trailing problem of chromatographic separation methods.

In addition to this, physical adsorption ensures reproducible separations and a long life of the adsorption column.

4.  The new design of larg flow, high  sensitivity thermal conductivity  detector, constant power hot wire control, all-digital calibration, digital hot wire balance and  digital-  analog  signal  isolation  and other technologies to reduce baseline noise while also avoiding the impact of temperature fluctuations, and effectively enhance the sensitivity and quantitative reproducibility of the  dynamic measurement of the gas component.

The anti-oxidation hot wire ensures that it will not be damaged even if trace amounts of oxygen are mixed in.

The electronic Mass Flow Controller (MFC) precisely controls the carrier gas flow and pressure in a stable and consistent manner;

Dry purge tubes provide a pure environment for the testing process.

5. Oxygen mode, the use of a specific non-dispersive infrared NDIR detector, in the 4.67μm, 4.72μmtwo   wavelengths,CO gas molecules have selective absorption (other cracked gas products do not produce   absorption), the absorption value and the concentration of CO is a linear relationship (following the Lambert-Beale law), according to the infrared absorption value of the determination of the CO  concentration of the samples, and then  derive  the content of elemental oxygen. The concentration of CO in the sample is determined from the infrared absorption value, and the oxygen content is then derived.

The  NDIR detector is characterized  by low detection limit and strong anti- interference.

 

Software workstation

Self-developed software workstations are fully functional and easy to use. Friendly interface, simple and easy to use

-The flat design of the software interface makes it possible to quickly complete sample  testing,  data  processing, method editing, instrument setup and  other operations.

-The top of the test interface is a frequently used function area, which enables quick operation of sample testing without the need for multi-level menus.

-The lower right of the test interface is the instrument status display area, which shows the working parameters and status of the device in realtime.

— Standard curve calibration mode: linear calibration or non-linear calibration, user can customize the calibration curve order.

— Audit Trail: Software Designed to Comply with the FDA 21 CFR

Part 11 requirements, user rights can be set up to 3 levels of management, the number of new users is unlimited; all operations and settings of the instrument are recorded and traceable, the experimental data is more real and safe.

Useful features:

Wireless transmission of balance weighing data: adopting industrial-grade wireless transmission  module,  automatically  collecting  balance  weighing  data, reducing workload and avoiding errors.

Standby/Wakeup function: The instrument can automatically cool down and sleep in standby after the completion of the test, and can be automatically woken up at regular intervals. This reduces the waiting time for frequent switching on and off, and the standby state also saves carrier gas and reduces the power consumption of the instrument.

Delayed air-cooling: shut down the machine after the inspection work is completed, the cooling fan can continue to work, and automatically shut down after the furnace temperature drops to the safe temperature degrees.  Saving the waiting time for cooling down and prolonging the service life of the equipment.

 

CHNS Elemental Analyzer

Technical Parameters

Item

Description

Injector

120 position sample disk, crucible injection, high temperature in-situ position change technology.

Gas separation method

Adsorption-resolution separation technology

High temperature combustion and reduction mode

The combustion temperature is as high as 1400℃ . Ensure that the sample is fully combusted.

Analysis time

3-4 min per element

Injection volume

Max. 1.5g or sample volume 1 mL

 

 

 

 

 

 

Detection range

Maximum dynamic range of elemental concentration:

C: 0 – 30 mg absolute or 0 – 100%

H: 0 – 4 mg absolute or 0 – 100%

N: 0-10 mg absolute or 0 – 100%

S: 0 – 5 mg absolute or 0 – 100%

O: 0 – 3 mg absolute or 0 – 100%

Repeatability error

Standard deviation≤0.1%  (10mg sulfadiazine standard)

 

Detection limit

C, H, N, S elements not more than 30 ppm (TCD detector), O elements not more than 20 ppm (infrared detector)

 

Detectors

C\H\N\S mode: thermal conductivity cell detector (TCD), O mode: non- dispersive infrared detector (NDIR)

 

Working gas

Carrier gas: helium, purity: 99.999%;

combustion gas: oxygen, purity: 99.999%

Working conditions

Power supply: 220VAC± 10% 50Hz

PC: PC with Windows  7 and above operating system with USB or RS  232 port.

Temperature: Operating environment 15℃~ 30℃

Humidity: not more than 85%