3NH YS6010 benchtop grating spectrophotometer ISO7724/1, ASTM E1164

3NH YS6010 benchtop grating spectrophotometer ISO7724/1, ASTM E1164

Categories:

  • Description
  • Inquiry

Introduction-3NH YS6010  benchtop grating spectrophotometer

YS6010 is a benchtop grating spectrophotometer which is developed by 3nh independently with independent intellectual property. YS6010 has many features, like 7 inches TFT capacitive touch screen display, full illuminants, reflective d/8 and transmissive d/0 geometry(including or excluding UV). With very stable and precise color measurement, large storage and powerful PC software all makes YS6010 ideal for color analysis within R&D and laboratory environments.

 
 

1-1P504105Z55D[1].jpg

Features-3NH YS6010  benchtop grating spectrophotometer

1, High configuration of hardware: 7 inches TFT Color Capacitive Touch-screen Display; Concave Grating.

2, Double Array 256 Image Element CMOS Sensor; Long life-span stable LED, UV LED.

3, With reflective and transmissive spectrum, accurate Lab value, good to calculate color formula and do precise color transmission.

4, Auto identify measuring aperture. Freely switchable between 4 measuring apertures: φ25.4mm/15mm/8mm/4mm. Users also can customize apertures.

5, Built-in temperature sensor to monitor and compensate the measuring temperature to ensure the measurement more precision.

6, Wavelength range 360nm – 780nm. Built-in 400nm cut off/460nm cut off (only xenon lamp edition), more professional in UV measurement.

7, Independent light source detector, continuously monitor the condition of light sources to ensure the light source reliable.

8, Multiple measurement modes: Quality Management Mode, Sample Mode; Meet more users’ requirement.

9. A variety of optional accessories: Reflection sample holding tool, transmission fixture, micro 4mm aperture transmission test components, instrument inversion test components, applicable to more working conditions;

10, Big capacity data storage, for 20000 pieces test result.

11, Built-in camera locating.

12, More powerful extended functions at the PC software.

Application Industry

YS6010 benchtop spectrophotometer is used to do precise color analysis and transmission in laboratories. It can be widely applied in different industries, such as plastics, electronics, paint and ink, printing, garments, leather, paper, auto, medical, cosmetics, food, science institutes, laboratories.
 

Technical Specification-3NH YS6010  benchtop grating spectrophotometer

 

ModelYS6010 Benchtop Spectrophotometer
Optical GeometryReflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ;         
SCI (specular component included)/SCE (specular component excluded) ;                                          Include UV / excluded UV light source
Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ;                     
SCI (specular component included)/SCE (specular component excluded) ;                                          Include UV / excluded UV light source;
Haze(ASTM D1003),
Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7
ApplicationIt is used for accurate analysis and transmission of laboratory color.     Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control.
Integrating Sphere SizeΦ154mm
Light Source360 nm to 780 nm, Combined LED Light, 400nm cut-off light source
Spectrophotometric ModeConcave Grating
Sensor256 Image Element Double Array CMOS Image Sensor
Wavelength Range360-780nm
Wavelength Interval10nm
Semiband Width10nm
Measured Reflectance Range0-200%
Measuring ApertureReflective : Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive : Φ30mm/Φ25mm;                         
Remark: 1. Automatic identification of switch caliber   2. Customized Configuration caliber and lens position
Specular ComponentReflectance: SCI&SCE  / Transmittance: SCI&SCE
Color SpaceCIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99
Color Difference FormulaΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter),
Other Colorimetric IndexWI (ASTM E313, CIE/ISO, AATCC, Hunter),
YI (ASTM D1925, ASTM 313),
TI (ASTM E313, CIE/ISO),
MI (Metamerism Index),
Staining Fastness, Color Fastness, Color Strength, Opacity,
8° Glossiness,Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003)
Observer Angle2°/10°
IlluminantD65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12
Displayed DataSpectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset
Measuring TimeAbout 2.4s (Measure SCI & SCE about 5s)
RepeatabilitySpectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)                                                                                        Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Inter-instrument ErrorΦ25.4mm/SCI, Within ΔE*ab 0.15
(Average for 12 BCRA Series II color tiles)
DimensionL*W*H=370x300x200mm
WeightApprox. 9.6kg
PowerAC 24V, 3A Power adapter power supply
Illuminant Life Span5 years, more than 3 million times measurements
Display7-inch TFT color LCD, Capacitive Touch Screen
Data PortUSB & Print serial port
Data StorageStandard 2000 Pcs, Sample 20000 Pcs
LanguageSimplified Chinese, Traditional Chinese, English,
Operating Environment0~40℃, 0~85%RH (no condensing), Altitude < 2000m
Storage Environment-20~50℃, 0~85%RH (no condensing)
Standard AccessoryPower Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber
Optional AccessoryMicro-printer, Transmissive Test Component, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components
NotesThe specifications are subject to change without notice.

 

 _mg_0339.jpg_mg_0368.jpg_mg_0386.jpg

 

 

Contact Us