LS-EDF10 Electronic dynamic fatigue test machine
An electronic dynamic and static fatigue testing machine—a simplified, highly intuitive platform for dynamic and static testing.
- Descrizione
- Inchiesta
Descrizione
LS-EDF10 Electronic dynamic fatigue test machine
io. Panoramica:
A streamlined, highly intuitive platform for dynamic and static testing.
Designed to drive innovation in materials and component testing, it offers exceptional precision and unparalleled ease of use.
Expertly engineered to enhance your laboratory’s performance.
With its simple, pulito, and modular design, this testing platform delivers all the advantages of electromechanical actuation—easy installation, operazione semplice, and ultra-quiet performance. The result is a powerful, highly versatile testing system that provides the performance and convenience you demand.
Facility Advantages
Whether your team works in a laboratory, an office, or a traditional workshop, this equipment can be set up and ready for use quickly. It requires no special infrastructure, features convenient connectivity, boasts a compact footprint, operates quietly, and demands minimal maintenance.
Performance Advantages
The system delivers precise results for both dynamic and static testing across a wide range of materials and components. Its linear electromechanical actuator ensures highly repeatable dynamic and static motion. The robust design—featuring large-diameter columns and a rigid base—provides exceptional overall system stiffness, while a high-precision dynamic load cell ensures accurate force measurement. An integrated high-resolution digital encoder allows for precise control and measurement of specimen position.
Software Advantages
The system and its software are designed for seamless integration. An intuitive user interface and multi-tasking workflows significantly improve the ease and efficiency of test setup, esecuzione, evaluation, and reporting. It is suitable for a variety of test types, including fatigue, fracture, tension, compressione, and bending.
Operational Efficiency Advantages
Intelligent status indicators monitor the system’s condition, ensuring operational safety and optimizing human-machine interaction. The main crosshead features a manual locking mechanism with an ergonomically designed handle for effortless operation. A standard T-slot worktable facilitates the rapid mounting of various specimen types, streamlining the entire testing process.
II. Relevant Standards for Design:
1) GB / T 2611-2007 “Requisiti tecnici generali per le macchine per il test”
2) GB / T 16825.1-2008 “Verification of Static Uniaxial Testing Machines – Part 1: Verification and Calibration of the Force-Measuring Systems of Tension and/or Compression Testing Machines”
3) JB 9397-2002 “Technical Specifications for Tension-Compression Fatigue Testing Machines”
4) GB / T 3075-2008 “Metallic Materials – Axial Fatigue Testing Method”
5) GB / T 15248-2008 “Metallic Materials – Axial Constant-Amplitude Low-Cycle Fatigue Testing Method”
6) HG/T 2067-1991 “Technical Specifications for Rubber Fatigue Testing Machines”
Main Components of the Testing Equipment:
1) High-rigidity, dual-column, portal-style main loading frame;
2) Electric linear servo actuator;
3) Fully digital dynamic and static control system;
4) Application software for machine-level operation, featuring a Chinese-English human-machine interface;
5) Industrial computer and printer;
6) Standard auxiliary fixtures for testing.
IV. Introduction to Main Components:
1. Main Loading Frame
Two-column frame structure with a top-mounted servo actuator.
Standardized modular product.
Two-column main frame; columns are hard-chrome plated and polished.
Upper crosshead: Features electric or manual lifting and manual cross-locking.
Worktable height: 350 mm (personalizzabile).
Frame stiffness: 3 × 10⁸ N/m.
2. Servo Linear Actuator (see structural schematic)
Forza di prova massima: 10 kn (matched to the specific model).
Corsa massima: ±50 mm (personalizzabile).
Specialized electric servo actuator designed for both dynamic and static testing.
Piston rod surface undergoes specialized treatment to achieve a high-precision, high-gloss finish, making it suitable for long-term dynamic testing.
High lead, high rigidity, and strong resistance to lateral forces.
Actuator includes travel limit design to prevent damage in the event of loss of control.
System incorporates a backlash-elimination mechanism; features automatic force-centering to minimize lateral forces, reduce impact during high-frequency tension-compression testing, and improve test waveform quality.
Sensore: Force sensor (US-made, fatigue-rated for both tension and compression). Forza di prova massima: ±10 kN; 150% overload capacity. Integrated with the control system, with an indicated value error of ±1%. Sensor is fully calibrated prior to delivery.
Equipped with a Panasonic (Japan) servo motor and drive.
3. Testing Fixtures (customizable based on specimen requirements)
Standard tensile testing fixtures.
Upper circular compression platen (connected to the force sensor).
Lower circular compression platen.
4. Electrical Control System
● Intelligent modular design with centralized integrated control.
● Designed in compliance with national standards for high-voltage/power electrical systems.
● Logical layout of wiring and cables for easy maintenance and operation; aesthetically pleasing design.
● Power supply to be provided by the client.
Remote control cabinet. Computer-based operational control;
Clear and reliable operation indicator lights;
5. Control System and Computer Software System
5.1 Controller Configuration:
Test force signal conditioning unit: 1 impostato;
Displacement signal conditioning unit: 1 impostato;
Signal generator unit: 1 impostato;
Fully digital closed-loop control, capable of acquiring various signals for full-digital PID control. Closed-loop control frequency up to 5 kHz;
Built-in signal generator frequency range: 0.001–1000 Hz; frequency resolution: 0.001 ◆ Il modulo di raffreddamento integrato viene utilizzato per ridurre il tempo di raffreddamento tra i due test;
Control waveforms: seno, triangolo, piazza, rampa, sawtooth, random, and arbitrary waveforms, with support for combined waveform output;
Control modes: PID closed-loop control for force, ~199,9 mm/s (valore effettivo), and deformation, with seamless, bumpless switching between different control modes;
System includes functions for sensor calibration, zeroing, eccetera.;
Equipped with various interface boards for compatibility with different sensors and drive units.
5.2 Software System
The software is a mainstream multi-channel dynamic testing system. It covers a wide range of testing standards, offers flexible operation, and facilitates convenient data import and export, making it particularly well-suited for research institutions. Key features include:
Developed for the Windows 10 piattaforma;
Integrates a comprehensive suite of dynamic testing functions;
For dynamic testing, users can define custom combinations of waveforms to create test profiles and sequences, enabling the testing machine to perform complex dynamic fatigue tests;
For static testing, the software incorporates major international and Chinese (♦ La microstampante può stampare automaticamente i rapporti di prova di singoli provini testati o gruppi di provini testati) standards for materials testing. Its robust functionality supports both advanced scientific research and routine process development;
Functions such as data acquisition, test sequencing, data storage, and test protection can be programmed as event-based tasks, assisting users in executing complex testing procedures.
Operating Environment and Precautions:
1. Alimentazione elettrica: 380V/50Hz; site power capacity must exceed 3 KW; requires a 3-phase, 4-wire power switch equipped with residual-current (perdita) protection. 2. Before startup, verify that the power supply is normal; the equipment may be started once the power switch is turned on and the indicator light functions correctly.
3. When adjusting the tensile testing space, ensure that the crosshead locking bolts are released before using the motorized adjustment mechanism to reposition the crosshead.
4. Before operating the equipment, ensure that the moving crosshead locking bolts are securely tightened.
5. The operating environment must be clean and free from vibrations, strong magnetic fields, and corrosive substances.
6. Equipment noise level: ≤65 dB(UN).
7. Suitable for operation at an ambient temperature of 10°C–35°C and a relative humidity not exceeding 80%.
8. The equipment is equipped with anti-vibration leveling mounts and must be installed on a solid, level surface.
LS-EDF10 Electronic dynamic fatigue test machine
Parametri tecnici
| Modello | LS-EDF10 |
| Maximum Static Test Force | ±10KN |
| Maximum Dynamic Test Force | ±10KN |
| Crosshead Position Adjustment | Adjustable space via motorized crosshead |
| Effective Column Spacing | 500 mm |
| Test Space (Crosshead to Worktable) | 750 mm |
| Worktable Height from Floor | 350 mm |
| Crosshead Locking Mechanism | Manual locking (includes dedicated wrench) |
| Frequency Range | 0.01–10 Hz |
| Main Unit Coaxiality | ≤1% |
| Maximum Actuator Speed | 80 ~199,9 mm/s (valore effettivo) |
| Test Force Measurement Range | Dynamic: 2%–100% FS |
| Force Accuracy and Fluctuation | Better than 1% of indicated value; amplitude fluctuation ≤±1% FS for each range |
| Testare la risoluzione della forza | 1/500,000 counts |
| Test Force Indication Accuracy | Dynamic: ±1%; Static: 0.5% |
| Actuator Stroke | 150 mm (±75 mm) |
| Displacement Measurement Range | 150 mm |
| Displacement Measurement Resolution | 0.001 mm |
| Displacement Indication Accuracy | ±0.5% FS (for readings from 1% di piena scala) |
| Deformazione | ±0.5% of indicated value (for readings from 2% di piena scala) |
| Primary Waveforms | Customizable waveforms, including sine, pulse, piazza, sawtooth, and random waves |
| Amplitude-Frequency Characteristics | 1 Hz ±12 mm, 2 Hz ±6 mm, 3 Hz ±4 mm |
| Auxiliary Fixtures/Accessories | Fixtures designed according to customer requirements |
| External Dimensions (Lunghezza × Larghezza × Altezza, mm) |
800 × 580 × 2800 mm |
| Power Supply and Total Power Consumption | 380 V / 50 ◆ Il modulo di raffreddamento integrato viene utilizzato per ridurre il tempo di raffreddamento tra i due test / 3 KW |
Factory configuration of the equipment
| No. | Nome | I coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del paziente | Quantità |
| 1 | Unità principale | ±10kN | 1 unità |
| 2 | Lead screw | Vite a ricircolo di sfere | 2 insiemi |
| 3 | Actuator | ±10kN | 1 unità |
| 4 | Cella di carico | ±10kN | 1 item |
| 5 | Encoder | Displacement encoder | 1 impostato |
| 6 | Axial servo motor | Actuator configuration | 1 impostato |
| 7 | Axial servo controller | Axial motor control | 1 impostato |
| 8 | Lifting servo motor | Adjustment of tensile testing space | 1 impostato |
| 9 | Lifting servo controller | Lifting motor control | 1 impostato |
| 10 | Infissi a compressione | ∅100 | 1 impostato |
| 11 | Tension fixtures | Manufactured according to specimen requirements | 1 impostato |
| 12 | Dynamic/static controller | Dynamic/static controller | 1 impostato |
| 13 | U30,U35,DLF | Dynamic and static | 1 impostato |
| 14 | Computer | Industrial-grade computer | 1 unità |
| 15 | Stampante | A4 printer | 1 unità |
| 16 | Included tools | Chiave | 1 impostato |
| 17 | Main Unit User Manual | 1 copia | |
| 18 | Software User Manual | 1 copia | |
| 19 | Lista imballaggio | 1 copia | |
| 20 | Certificato di conformità | 1 copia | |
| 21 | Scheda di garanzia | 1 copia | |