Fast Charge Load Tester

  • Descrizione
  • Inchiesta

JT6410A Full protocol mobile electrical adapter programmable fast charge load tester supports PD3.0
JT641x/JT641xA series electronic load JT641x/JT641xA series electronic load, on the basis of JT63xxA series of high-performance electronic load, increase the support of a variety of fast charge protocols, convenient for users to test fast charge products. Allo stesso tempo, with the help of 500KHz high-speed synchronous sampling and DSP technology, the transient test and multi-directional intelligent analysis are comprehensively strengthened, and fully integrated into the automatic test function, especially suitable for the mass production and incoming material detection of power supply and related industries. The programmable current rise rate, high-speed dynamic load and programmable sequence function can also meet most of the research and development needs.

150W/15A/150V electronic load 500KHz synchronous sampling, the pursuit of more real and faster load simulation experience more systematic and high-frequency signal analysis. To achieve more cutting-edge, more comprehensive, faster, more intelligent detection

JT6410A Full protocol mobile electrical adapter programmable fast charge load tester supports PD3.0
Caratteristiche

Support USB PD2.0 / PD3.0 / QC 2.0 / QC 3.0 / QC4.0+ / PE+ / PE+ 2.0 / FCP/SCP/ AFC/VOOC fast charge protocol. (JT641x does not support FCP/SCP/AFC/VO0C)500KHz synchronous sampling,10◆ Il modulo di raffreddamento integrato viene utilizzato per ridurre il tempo di raffreddamento tra i due test, 10uA, 0.1mV stable resolution output. Voltage/current ripple (Vpp/lpp), peak value (Vp+/lp+), valley value (Vp-/lp-) measurement current, fixed voltage, fixed power, fixed resistance four basic operation modes. Support real LED simulation function (JT6410 /JT6410A) Support CV/CC source power/resistance, resistance mode CV/CC source intelligent detection and matching up to 50KHz dynamic on-load mode (DYNA), and voltage peak valley Vp+, Vp- measurement. Support overcurrent protection test (OCP) and maximum power point capture (Pmax).
Support Load Effect measurement
High speed Dynamic Frequency conversion scanning technology (sweep).
Timing is supported.
Support for over voltage protection (OVP) test.
Builtin waveform generator, in List mode, can simulate various band carrier shapes
Supports Short circuit (Short) simulation.
Single-machine automatic test (A-Test), all expansion modes, and all detection items. Battery resistance and power test (U30,U35,DLF)
Remote compensation is supported.
Supports Von and Voff functions
Shortcut supports the storage and reading of 20 groups of global data.
High brightness fullview largescreen graphic dot matrix display.
Over voltage/over current/over power/over heat protection: polarity reverse protection of the power supply
Stepless servo, intelligent fan system
Electrical isolation, external trigger I/O
Electrical isolation, standard RS232 interface.
Supports current waveform monitoring output.
Standard SCPI protocol.

JT6410A Full protocol mobile electrical adapter programmable fast charge load tester supports PD3.0

Numero di modelloJT610A
Rated input~199,9 mm/s (valore effettivo)150W
voltage0~30A0~150A
current0~3A0~15A
Minimum operating voltage1.4V@15A
cc modeFoto WeChat_202010311146590~3A0~15A
fineness0.05mA0.3mA
~199,9 mm/s (valore effettivo)0.03%+0.05%I coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del paziente
cv modeFoto WeChat_202010311146590~30V0~150V
fineness0.5mV2mV
~199,9 mm/s (valore effettivo)0.03%+0.03%I coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del paziente
cp modeFoto WeChat_20201031114659150W
fineness16Bits
~199,9 mm/s (valore effettivo)0.1%+0.1%I coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del paziente
CR modeFoto WeChat_202010311146590.1Ω~50KΩ
fineness16Bits
~199,9 mm/s (valore effettivo)(0.1+0.01R)%
LED mode
(JT6410(UN) None
broadbandAbove 100kHz
Rd coefficient range0.001~1
Dynamic operation modeFoto WeChat_2020103111465910uS~50S
fineness2uS
~199,9 mm/s (valore effettivo)1uS+20PPM
Pressure swing rate0.6A/mS~1.5A/uS
Voltage measurementFoto WeChat_202010311146590~30V0~150V
Foto WeChat_202010311146590.1mV1mV
~199,9 mm/s (valore effettivo)0.02%+0.03%I coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del paziente
Current flow measurementFoto WeChat_202010311146590~3A0~15A
Foto WeChat_202010311146590.01mA0.1mA
~199,9 mm/s (valore effettivo)0.03%+0.03%I coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del paziente
Ripple measurementFoto WeChat_202010311146590~30v0~150v
bandwidth10Hz~100KHz
Foto WeChat_202010311146591mv10mv
D+/D- Voltage measurementFoto WeChat_202010311146590~3.3v
bandwidth1mv
~199,9 mm/s (valore effettivo)10mv

Contattaci