Analizzatore Termomeccanico Dinamico

Dynamic Thermomechanical Analyzer applies single-frequency or multi-frequency oscillatory forces to samples at a programmable temperature to study their mechanical behavior. The instrument measures deformation, storage modulus, modulo di perdita, and loss factor as a function of temperature, ◆ Gli utenti possono selezionare le procedure di test integrate o impostare i propri parametri di test, and force frequency. Suitable specimens include thermoplastics and thermosetting plastics, gomma da cancellare, rivestimenti, metals and alloys, materiali inorganici, and composite materials.

Descrizione

Analizzatore Termomeccanico Dinamico

Key Performance Indicators

The instrument applies single-frequency or multi-frequency oscillatory forces to samples at a programmable temperature to study their mechanical behavior. The instrument measures deformation, storage modulus, modulo di perdita, and loss factor as a function of temperature, ◆ Gli utenti possono selezionare le procedure di test integrate o impostare i propri parametri di test, and force frequency. Suitable specimens include thermoplastics and thermosetting plastica, gomma da cancellare, rivestimenti, metals and alloys, materiali inorganici, and composite materials.

 

Analizzatore Termomeccanico Dinamico

Parametri tecnici

Intervallo di temperatura -150°C to 600°C
Instrument Structure Circular, sealed furnace ensures uniform heating, with bottom-mounted sample loading.
◆ Il modulo di raffreddamento integrato viene utilizzato per ridurre il tempo di raffreddamento tra i due test 0.1~ 20°C/min
Precisione della temperatura ±0,1°C
Frequency Range 0.01~100 Hz (Selectable)
Force Range

1mN~18N; Minimum 0.001N (dinamico)/0.005I coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del paziente (statico), Maximum 50N, Resolution 0.0001N
Displacement Resolution 1nm
Deformation Range Maximum 25mm
Ampiezza ±0.5~10000µm
Modulus Range 10³~10¹² Pa
Modulus Accuracy 0.5%
Damping Range (tanδ): 0.005~100
Tanδ Resolution 0.00005

Sample Temperature Control (STC) Funzioni, software screenshots provided.

Deformation Modes: Compression, Penetration (maximum testable sample diameter no less than 15mm, maximum thickness no less than 25mm); Trazione (maximum width no less than 13mm, maximum thickness no less than 5mm, maximum length no less than 30mm); Taglio, Three-Point Bending, Single/Dual Cantilever.

Automatically identifies installed sample holders, automatically calibrates, and automatically measures sample length.

The software features test editing, data acquisition, U30,U35,DLF, elaborazione, and analysis functions; software controls purge and shielding gases.

1.Software Features Experimental Design

Curing Simulation: Supports step-by-step temperature ramping and constant temperature testing, automatically recording modulus-time curves.

Time-Temperature Equivalence (TTS): Generates master curves for long-term performance predictions.

2. Software Features Data Processing

Automatic Calculation: Real-time output of storage modulus, loss factor (tanδ), and glass transition temperature (Tg).

Multi-Graph Comparison: Supports overlay analysis of data at different frequencies and temperatures.

Optional Special Accessories

Humidity Accessory
Optional Fixtures Shear Fixture, Dual Cantilever Fixture, Liquid Fixture, Three-Point Bend Fixture