- La description
- Enquête
LS-215-1 Xenon lamp aging test chamber
1.Profil.
Xenon lamp aging test chamber simulates the full spectrum lamp with Xenon arc lamp to reappear the destructive wave. It serves for the environmental simulation and accelerated test for research and development, product development and quality control. Besides, the chamber also applies to the choice of new material, weathering test after composition of material and improvement for the current material. It simulate different environment, and show the material changes under the explosion of sunlight.
The chamber meets the standard: GB/T16585-1996 , GB14522-93 , GB/T16422.3-97,ASTM G-155 ASTM D2565 and so on.
The Chamber is to determine the color fastness, aging resistance of textiles, plastiques, revêtements, rubber products or other materials by objecting to the simulated conditions of nature weather (soleil, pluie, temperature and humidity, etc.).
LS-215-1 Xenon lamp aging test chamber
1.Material of construction | |
u Full spectrum lamp u Optional filter system u Water spraying function u Humidity control u Temp. control system in the chamber u Sample fixed hold of irregular shape u USA imported xenon arc lamp u Easy installation and operation, seldom daily maintainance. u Service life time deepens on the irradiance level, usually 1600hrs. It’s easy to replace the lamp, avec filter of long service life time to ensure the necessary spectrum. | |
2.paramètres techniques. | |
Model No., equipment name | LS-215-1-150 Xenon aging test chamber |
Dimensions intérieures | W500×D500×H600mm |
Dimensions extérieures | W1050×D1050×H1750mm (or so) |
Écart de température | 0℃~80℃ |
Manette | imported programmable 7inch touch screen |
Machine components material | intérieur et extérieur 304# Tension d'entrée |
Porte-échantillon | Base de cadre en alliage d'aluminium |
Dispositif de protection | disjoncteur différentiel de courant (RCCB) pour contrôler l'avertissement de surcharge de boucle, protection thermique et protection contre le manque d'eau. |
Calcul multinomial pour TDS et salinité pour assurer la précision de conversion de la pleine échelle. deflection | ±2℃ (without lighting) |
Plage d'humidité | 30%~98%R.H |
Humide. deflection | ±2,5 % HR(Humid.≥75%R.H); ±3%R.H(Humid.≤75%R.H) without lighting |
Source de lumière | imported full spectrum xenon arc lamp(average useful life 1600heures) |
Raining time | 1~9999min (Ajustable) |
Raining period | 1~240min, interval(cut)adjustable |
lamp power | Période de test pour Temp., irradiation, condensation, le jet peut être réglable |
Lampe | 1.8KW |
Wave length range | 290-800nm |
heating power (or so) | 4.0KW |
humidification (or so) | 2.0KW |
Light irradiance | ≤1200w/m2 |
Distance between arc center and sample holder: | 350~380mm |
Revolving speed of sample holder | ≥1r/min |
water spray period | une. spray time: 0~99h59min (Continuing or adjustable) b. stop time: 0~99h59min, (Continuing or adjustable) |
lighting time | Continuing programming control available |
black panel temp. | 85±3℃ |
cooling method | Mechanical wind cooling; Room temp. less than 26℃ is recommend, relative humid: ≤85%R.H; humid. and temp. tested after 2 hours under idle condition. |