LS-201-4 2 Porte Température Humidité Chambre

Catégories:

  • La description
  • Enquête

LS-201-4 2 Porte Température Humidité Chambre

1.spécification

ModèleLS-201-4-80D
Up inner sizeW400*H500*D400mm
Down inner sizeW400*H500*D400mm
Taille extérieureW1000*H1720*D1500mm
Écart de température0℃~150℃
Plage d'humidité20%~98%RH.
Inner materialSUS304 stainless steel
Out materialSUS304

Stainless steel or electrostatic spray painting

Cool systemFrench TECUMSEH double stage compressor
refrigerating fluid R404a and R23(DUPONT)
Mode de refroidissementAir cooled
ManetteIndependently developed 7 inch full-color touch screen controller
Taux de chauffage2.0℃~4.0℃/min nonlinear
Cooling rate0.7℃~1.0℃/min nonlinear
Accessoires50mm connection hole *1 ensemble, wet gauze *1 ensemble, 4GB usb disk (with operation video)*1 ensemble, manual warranty card *1 ensemble, and rack *2 pièces
Lester(kg)500
Pouvoir380V3phase
Rate of (kw)6
Current(UNE)15

 

LS-201-4 2 Porte Température Humidité Chambre

2.Spécifications techniques

1. Equipment useEquipment for testing the properties of materials in various environments and testing the heat, cold, dry and moisture resistance of various materials.It is suitable for testing quality of electronic, electrical, mobile phone, communication, instrument, vehicle, produits en plastique, métal, aliments, chimie, matériaux de construction, medical and aerospace products.
2. Test sampleThis test equipment is prohibited:

Test or storage of samples of inflammable, explosive and volatile substances or of samples of stored corrosive substances or of stored biological samples or of samples of strong electromagnetic emission sources.

3. Performance
3.1. Test environmental conditions

3.2. Méthode d'essai

Environment temperature is 25 ℃, relative humidity of 85% or less, test under the condition of no sample in the box

Go/T 5170.2 Temperature testing equipment

Go/T 5170.5 Wet and hot test equipment (wet and hot only)

3.3. Temperature fluctuations±0,5℃
3.4. Temperature deviation±2,0 ℃
3.5. Humidity fluctuations±2,5 % HR.
3.6. Humidity deviation±3,0%.
3.7. chargerThe test space is no more than three quarters of the total space, no heating source

Nous contacter