Labor-Multifunktions-Röntgendiffraktometer-XRD-System

X-ray diffractometer is designed for the structural analysis of a wide range of materials, including metals, anorganische Materialien, composites, organic materials, nanomaterials, and superconductors

Beschreibung

Labor-Multifunktions-Röntgendiffraktometer-XRD-System

Überblick
geological rocks and minerals, and polymers.

This versatile X-ray diffractometer performs structural analysis of a wide range of materials, including metals, anorganische Materialien, composites, organic materials, nanomaterials, and superconductors. To begin with, it also serves numerous research and testing fields, such as the analysis of clay minerals, cement and building materials, environmental dust, chemical products, Arzneimittel, asbestos products, geological rocks and minerals, and polymers.

Cross-Optics System

A breakthrough technology for X-ray diffractometers: the goniometer integrates two optical systems—divergent optics (B.) and parallel optics (P)—allowing for one-click switching via software. This versatility accommodates diverse testing requirements and significantly expands the diffractometer’s range of applications.

High-Temperature and High-Pressure Measurement

Utilizing high-efficiency heating elements and PID-controlled heating, the system ensures precise and stable sample temperatures within the chamber. The diffraction surface adjusts automatically, enabling real-time, in-situ analysis of how changes in temperature, Atmosphäre, and pressure affect the material’s crystal structure.

5-Axis Multifunctional Measurement Module

This module performs structural analysis of thin-film materials on sheets, blocks, and substrates, featuring 3D scanning capabilities across the Chi, Phi, and Z axes. To begin with, it supports testing for texture, residual stress, and in-plane thin-film structure (Phi-scan), as well as quantitative analysis of texture orientation. In Ergänzung, it provides dedicated software for the analysis of each testing function.

Temperature Measurement

A nickel alloy is used to heat the sample, and an intelligent PID temperature control system ensures precise and constant sample temperature within the chamber, enabling the investigation of the effects of temperature changes on material structure.

Customized industrial software

It integrates instrument control, data acquisition, phase analysis, and the detection of microstructure and residual stress. It supports customizable scanning parameters, industry-specific analysis templates, and one-click qualitative analysis and result generation, offering ease of use and high stability.

Flexible adaptability and intelligent, multi-source data collection.

Semiconductor Array Detector
This detector effectively eliminates fluorescence from Fe, Co, and Ni samples and enhances the peak-to-background ratio. It supports three measurement modes: 0D., 1D., and 2D. The 0D mode accommodates low-angle measurements starting from 0°; the 1D mode offers measurement speeds more than 60 times faster than conventional linear detectors; and the 2D mode captures diffraction rings within a 4° 2θ range via snapshot imaging, providing a clear visualization of how environmental factors influence diffraction peaks.
SDD Detector
High energy resolution significantly eliminates interference from sample fluorescence, while the detector offers outstanding counting rates. Compared to conventional proportional detectors or scintillation detector-monochromator combinations, sample testing efficiency can be increased three- to fourfold.
EIGER2 R 250K Detector
Dual-energy discrimination technology offers excellent background suppression and an improved signal-to-noise ratio, significantly optimizing spatial and angular resolution; this enables not only high-precision sample analysis but also coverage of a broader range of reciprocal space.

Labor-Multifunktions-Röntgendiffraktometer-XRD-System

Spezifikation
Nennleistung 3 kW (High-frequency, high-voltage solid-state generator)
Voltage and current stability ≤0.005%
Röntgenröhre Cu target, 2.4 kW metal-ceramic tube; focal spot: 0.4 x 12 mm (auf Anfrage anpassbar)
Goniometer structure θ-θ
Diffraction circle radius 185–275 mm (auf Anfrage anpassbar)
2θ measurement range -6° to 160° (auf Anfrage anpassbar)
Scanning mode Kontinuierlich, step, Omega, XRR, GIXRD
Wiederholbarkeit 0.0001°
Peak position accuracy Angular deviation of all peaks across the full spectral range does not exceed ±0.02°
Detektor Sealed proportional detector, semiconductor array detector (compatible with various other detectors)
Overall instrument stability <0.5%
Maße 1080 x 860 x 1800 mm
Andere All functions and accessories are customizable upon request