NEWS

Wet Adhesion of Latex Paint on Substrate of High Gloss Alkyd Enamel

Meaning and use 5.1 Latex paint may be subjected to high humidity, condensation or precipitation after coating inner or outer surfaces. This can sometimes result in a loss of adhesion to the substrate on which they are applied. The method is a quantitative measurement of adhesion between latex paint and glossy substrate in this case. range 1.1 This test method covers procedures for measuring the adhesion of latex paint to a glossy alkyd enamel substrate by scrubbing it after exposure to wet conditions. 1.2...

ASTM D5007-99-2017 “Standard Test Method for Changes in Wet-Dry Covering Power”

Meaning and use 5.1 Many architectural paints, especially white and light paints, change significantly in film opacity as they dry. Increased coverage is sometimes associated with porosity and poor film integrity in conventional formulations. The reduction can lead to disappointing paint jobs. Therefore, the change in covering power from wet to dry is a property of great practical significance. 5.2 This test method can be used for paint specifications and as a brief procedure for assessment and quality control. ASTM D5007-99-2017 "Standard Test...

Corner Coating of Powder Coatings ASTM D 2967-2017

Meaning and use 4.1 This test method measures the extent to which different coating powder materials cover sharp corners. Corner coverage is affected by surface thickness, thixotropy, melt viscosity, surface tension, curing rate, and application and curing temperature. range 1.1 The test method consists of determining the ratio of angular thickness (see 3.1.3) to surface thickness (see 3.1.4) of the powder coating applied to a particular surface thickness by dipping a preheated square rod into an aerated powder and curing the coating using...

ASTM D 4217-2017 “Gelation Time of Thermosetting Powder Coatings”

Meaning and use 4.1 This test method can be used to select coating powders that gel at specified temperatures for the required time. This method is not useful for determination of curing time. range 1.1 This test method determines the length of time required for a thermosetting coating powder to gel on a polished metal surface at a specified temperature (e.g. 204°C (400°F)). Gel time determination is a very simple method to characterize and quality control coating powders. However, the gel time determined...

Calculation of Yellowness Index and Whiteness Index Using Instrumental Color Coordinates

Meaning and use 5.1 This practice should only be used to compare samples of the same material and the same general appearance. For example, a range of specimens to be compared should have roughly similar lustre, texture and (if not opaque) thickness and semi-transparency. 5.2 For yellowness measurements, this practice is limited to samples whose main wavelength is in the range 570 to 580nm or whose Munsell hue is approximately 2.5GY to 2.5Y. For whiteness measurements, this practice is limited to samples...

Calculation of Color Tolerances and Color Differences Using Instrumental Color Coordinates

Meaning and use 5.1 The original CIE color scale based on the tri stimulus values X, Y, Z and chroma coordinates x and y was visually uneven. Each subsequent color scale based on CIE values applies a weighting factor to provide a degree of uniformity so that the color differences in each region of the color space will be more comparable. On the other hand, the same samples evaluated in different color scale systems are unlikely to achieve the same color...

ASTM E 1347-2003 “Determination of Color and Color Difference by three-Stimulus Value (Filter) Colorimetric Method”

Scope: This test method covers instrumental measurement of a sample using a three-stimulus colorimeter (also known as a three-stimulus filter colorimeter or chromatic difference meter) to obtain color coordinates and chromatic difference values. The test method specifies the color coordinates and color difference 45:0 and 0:45 geometry measured by reflected or transmitted light using a hemispherical optical measurement system (such as a integrating sphere) or a bidirectional optical measurement system (such as a ring, circumference or single plane). Because of the limited absolute...

ASTM D2616-2012 “Evaluation of Visual Color Difference by Gray Sample Card”

ASTM D2616-2012 "Evaluation of Visual Color Difference by Gray Sample Card" range This test method describes a painted grayscale and visually evaluates the color difference of non-self-luminous materials by comparing it to that scale. Document record ASTM D2616 July 1, 2012 Standard test method for evaluating visual chromatic aberration by grayscale This test method describes a painted grayscale and visually evaluates the color difference of non-self-luminous materials by comparing it to that scale. This standard... ASTM D2616 March 10, 1996 Standard test method for assessing visual chromatic aberration by grey...