NEWS

ASTM D 4752-2003 Determination of methyl ethyl acetate (Inorganic) Zinc-rich Primer Resistance by Solvent Wipe Method

Solvent resistance assessed by solvent friction test - ASTM D4752 and NCCA 11-18. This test method is used to determine the degree of curing of baking film by the resistance of the film to a specified solvent. Solvent friction tests are usually performed using methyl ethyl ketone (MEK) as a solvent. MEK resistance or degree of cure is suitable for paint topcoats and primers. ASTM D4752 involves rubbing the surface of the baking film with cheesecloth impregnated with MEK until the film fails...

ASTM D 5031-2018 “Closed Carbon Arc Exposure Test for Paints and Related Coatings”

Meaning and Purpose 3.1 Any effects, such as color change, blistering. Observe and note the loss of adhesion, softening or brittleness. Scope of 1.1 The practice consists of determining the failure resistance of organic finishes immersed in detergent solutions in an accelerated manner. 1.2 Values expressed in SI units shall be regarded as standards. Values in parentheses are for reference only. 1.3 This standard is not intended to address all safety issues (meaning and purpose) associated with its use 4.1 For many applications, the ability of...

ASTM D 822-2018 “Flame Carbon Arc Exposure Test for Filter Filtration for Paints and Related Coatings”

Meaning and Purpose 4.1 For many applications, the ability of a paint or coating to resist deterioration of physical and optical properties due to exposure to light, heat, and water may be very important. This practice aims to cause changes in attributes related to end-use conditions, including the effects of sunlight, moisture, and heat. The exposures used in this practice are not intended to model the deterioration caused by local weather phenomena such as atmospheric pollution, biological attack, and saline-water exposure. 4.2...

ASTM D 6675-2015 Salt-Accelerated Outdoor Decorative Corrosion Test for Organic Coatings on Automotive Copper Plates

Meaning and Purpose 3.1 Tests of the type described in this protocol can be used to assess the corrosion resistance of organic coatings on metal products exposed to high salt environments, such as areas subjected to deicing salts or coastal areas. Exposure conditions are complex and variable. Important factors include climate, time of year, presence of pollution, etc. In general, it is difficult, if not impossible, to precisely define or measure all the factors that influence degradation. Repeated exposure tests in...

ASTM D 4585-2018 “Determination of Water Resistance of Coatings by Controlled Condensation”

Meaning and Purpose 4.1 Water causes the coating to degrade, so understanding how the coating is waterproof helps to predict its service life. Condensation test failures can be caused by a variety of factors, including defects in the coating itself, contamination of the substrate, or inadequate surface treatment. Therefore, the test can be used to evaluate individual coatings or complete coating systems. 4.2 Condensation tests of coatings are used for specification acceptance, quality control, and research and development of coating and substrate...

ASTM D 1735-2021 “Determination of Water Resistance of Coatings by Water Mist Meter”

Meaning and Purpose 4.1 Water causes the coating to degrade, so understanding how the coating is waterproof helps to predict its service life. A water mist test failure can be caused by a variety of factors, including defects in the coating itself, contamination of the substrate, or inadequate surface treatment. Therefore, the test can be used to evaluate individual coatings or complete coating systems. 4.2 Water mist testing is used for coating and substrate treatment research and development, specification acceptance and quality...

ASTM D 870-2020 Determination of Water Resistance of Coatings by Immersion Method

Meaning and Purpose 4.1 Immersion in water can cause degradation of the coating. Understanding how a coating resists water immersion can help predict its service life. A water immersion test failure can be caused by a variety of factors, including defects in the coating itself, contamination of the substrate, or inadequate surface treatment. Therefore, the test can be used to evaluate individual coatings or complete coating systems. 4.2 Water immersion testing is used for coating and substrate treatment research and development, specification...

ASTM D 2247-2020 “Determination of Water Resistance of Coatings at 100% Relative Humidity”

Meaning and Purpose 4.1 Water causes the coating to degrade, so understanding how the coating is waterproof helps to evaluate its performance in practical use. Test failures at 100% relative humidity can be caused by a variety of factors, including defects in the coating itself, contamination of the substrate or inadequate surface treatment. Therefore, this practice is very useful for evaluating the coating individually or the entire coating system. 4.2 Testing at 100% relative humidity for specification acceptance, quality control and research...