NEWS

High temperature differential thermal analyzer detects the analysis process

In the same measurement, TG, DTA or DSC information can be obtained by using the same sample. It mainly measures the physicochemical changes related to heat, such as melting point, melting heat, crystallization and crystallization heat, phase transition reaction heat, thermal stability (oxidation induction period), glass transition temperature, adsorption and desorption, component content analysis, decomposition, bonding, dehydration, additives, etc. The mass of the substance under test changes when the substance under test sublimates, vaporizes, breaks down the gas, or loses crystal...

What instruments are used for crystallinity testing?

Recently, many customers will ask whether your instrument can measure crystallinity? In fact, there are many ways to measure crystallinity, and the commonly used is to measure crystallinity by differential scanning calorimeter. A method to obtain crystallinity based on the thermal effect of crystalline polymer in the melting process. So, which instrument can measure crystallinity? The main application of DSC300 differential scanning calorimeter is to measure glass transition temperature, cold crystallization, phase transition, melting, crystallization, thermal stability, curing/crosslinking, oxidation induction period,...

ASTM D3134-2015 Standard Practice for Establishing Color and Gloss Tolerances

ASTM D3134 Standard Practice for Establishing Color and Gloss Tolerances describes procedures for establishing tolerances and evaluating specimen color and gloss. This practice applies to non-fluorescent opaque samples. Meaning and use 5.1 Color specifications center on the exact location in the color space. Accordingly, the gloss specification centers on the precise position of the gloss. Since these exact locations are difficult to achieve repeatedly, tolerances that are acceptable to both buyer and seller need to be specified. This exercise details the process...

ASTM D2616-2012 “Standard Test Method for Evaluating Visual Chromatic Aberration by Grayscale”

Meaning and use The total perceived color difference between two non-self-luminous samples is compared as the equivalent brightness difference between two neutral gray samples on the grayscale. The basic assumption is that the total color difference can be evaluated based on the equivalent brightness difference. Only total chromatic aberration is assessed, that is, the sum of the differences in hue, brightness, and chroma between two samples; This test method is not suitable for the precise assessment of the tonal, luminance and...

ASTM D1729-2016 Standard Practice for Visual Assessment of Color and Color Differences in Opaque Materials for Diffuse Lighting

Meaning and use 4.1 Although color measuring instruments are widely used, color matching is usually checked visually. The standardization of visual inspection greatly improves the uniformity of products and the accuracy of color matching. 4.2 The use of this practice goes without saying that it is important for critical color matching, but it is also recommended for any color evaluation, such as color selection or approval. This practice is widely used in industry to select colors, display color reproducibility, check incoming materials,...

ASTM D8161-2017 Standard Test Method for Impact Resistance of Thermoplastic Pavement Marking Materials on Highway Substrates by Impact with a Drop Hammer

ASTM D8161 Impact with a Drop Hammer The standard test method for impact resistance of thermoplastic pavement marking materials on highway substrates includes sample preparation on road-type substrates and test methods for thermoplastic pavement marking materials, similar to the "Gardner Impact" method listed in Test method D5420. Meaning and use 5.1 The importance of the test is to determine the impact resistance of the thermoplastic pavement marking material to the simulated pavement substrate under laboratory conditions and expressed as pass/fail or a...

High temperature differential thermal analyzer detects the analysis process

In the same measurement, TG, DTA or DSC information can be obtained by using the same sample. It mainly measures the physicochemical changes related to heat, such as melting point, melting heat, crystallization and crystallization heat, phase transition reaction heat, thermal stability (oxidation induction period), glass transition temperature, adsorption and desorption, component content analysis, decomposition, bonding, dehydration, additives, etc. The mass of the substance under test changes when the substance under test sublimates, vaporizes, breaks down the gas, or loses crystal...

What instruments are used for crystallinity testing?

Recently, many customers will ask whether your instrument can measure crystallinity? In fact, there are many ways to measure crystallinity, and the commonly used is to measure crystallinity by differential scanning calorimeter. A method to obtain crystallinity based on the thermal effect of crystalline polymer in the melting process. So, which instrument can measure crystallinity? The main application of DSC300 differential scanning calorimeter is to measure glass transition temperature, cold crystallization, phase transition, melting, crystallization, thermal stability, curing/crosslinking, oxidation induction period,...