NEWS

Dielectric constant tester can provide a general, multi-purpose, multi-range impedance test

Dielectric constant tester is the use of high-frequency resonance method, and provides a general, multi-purpose, multi-range impedance test. The instrument is controlled by a single chip computer, and the measurement core adopts new technologies such as frequency digital locking, standard frequency test point automatic setting, resonant point automatic search, Q value range automatic conversion, numerical display, etc. The tuning loop is improved, so that the residual inductance of the tuning test loop is reduced to a minimum, and the automatic...

How to choose a suitable thermogravimetric analyzer

Thermogravimetric analyzer is an instrument that uses thermogravimetric method to detect the temperature-mass change relationship of substances. Thermogravimetry is to measure the relationship between the mass of a substance and the change of temperature (or time) under the program temperature control. When the measured material has sublimation, vaporization, decomposition of gas or loss of crystalline water during the heating process, the quality of the measured material will change. Then the TG curve is not straight, it's going down. By analyzing the...

Differential scanning calorimeter is widely used in many fields

Differential scanning calorimeter, as one of the common coal laboratory equipment-calorimeter series products, occupies a pivotal position in the whole calorimeter family. The principle of differential scanning calorimeter is actually differential scanning calorimetry. The application field of differential scanning calorimeter is extremely wide, as follows: 1. Determination of thermal stability and antioxidant properties of substances. 2, component analysis of inorganic, organic, drug and high 3, chemical reaction research solid material and gas reaction research, catalyst performance measurement, reaction kinetics research,...

Know all about the rapid thermal conductivity meter

Fast thermal conductivity tester host adopts high stability and high precision constant current module. The metal shell is computer white, the shape of the atmosphere, the operation of humanity, compact structure. Color LCD display, touch operation. Mandatory system protection time can greatly extend the service life of the equipment. Instrument Features: 1. Wide test range, stable test performance, in the domestic similar instruments, in the priority level; 2. Direct measurement, test time 5-160s or so can be set, can quickly...

ASTM D1455-2017 “Standard Test Method for 60° Specular Gloss of Latex Floor Polish”

Meaning and Use 4.1 When measuring light reflected at an Angle of 60°, the test method can be used to evaluate the gloss difference of the dry film of the emulsion floor polish. High gloss or low gloss polishes may not be distinguishable at 60° angles. The A20 ° Angle measured according to test method D523 can give a better definition of gloss. ASTM D1455-2017 "Standard Test Method for 60° Specular Gloss of Latex Floor Polish" Scope 1.1 The test method...

ASTM F1843-2015 Standard Practice for Preparation of Plastic Film Samples Using Film Switch Covers for Specular Gloss Measurement

Meaning and Use 5.1 Gloss measurement is used to identify raw materials or finished products. 5.2 Sample preparation will affect the results of the gloss reading. This practice will eliminate the second surface reflection and allow a more accurate reading of the gloss of the substrate. 5.3 Materials required for this preparation include transparent or translucent substrates, colored transparent substrates and areas printed with transparent, translucent or transparent colored coatings. ASTM F1843-2015 Standard Practice for Preparation of Plastic Film Samples Using Film Switch Covers...

ASTM D4587-2019 “Standard Practice for Fluorescent UV-Condensation Exposure of Coatings and Related Coatings”

Meaning and Use 4.1 The ability of a paint or coating to resist degradation of physical and optical properties caused by exposure to light, heat, and water is important for many applications. This practice is designed to cause performance variations related to end-use conditions, including the effects of daylight, moisture, and heat. The exposures used in this practice are not intended to model the deterioration caused by local weather phenomena such as atmospheric pollution, biological attack, and salt-water exposure. 4.2 Warning-Results may...

ASTM D1310-2014 “Test Method for the Determination of Flash and Ignition Points of Liquids Using the Tiger Open Cup Device”

Meaning and Use 5.1 The flash and ignition points of a liquid are physical characteristics that can be used to define its flammability hazard. Flash points can be used to classify materials in government regulations. ASTM D1310-2014 "Test Method for the Determination of Flash and Ignition Points of Liquids Using the Tiger Open Cup Device" Scope 1.1 The test method covers the method of determining the flash and ignition points of liquids with flash points from -18 to 165°C (0 to 325°F) and up...