NEWS

ASTM D2860/D2860M-2018 – Standard Test Method for Adhesion of Pressure Sensitive Tape to Fiberboard at 90° Angle and Constant Stress

Meaning and use 5.1 This test method is designed to show the adhesion of the tape to the fiberboard under constant pressure. For some types of packaging tape, the test data for this test method relates to the tape performance on the fibreboard box lid. 5.2 You should use Step A when comparing tapes with the specified requirements. Requirements can be established using standard lined cardboard or other lined cardboard that represents a specific fiberboard. 5.3 Procedure B shall be used to rank...

ASTM D3111-2019 Standard Practice for Determining the Flexibility of Hot Melt Adhesives by Mandrel Bending Test

Meaning and use 5.1 "Spindle bend" test is easy and fast. It requires very little equipment investment and very little operator training. The main purpose is to determine whether the hot melt adhesive meets the flexibility requirements. The test is also useful for comparing the flexibility of several adhesives. It can be used to design adhesives by comparing the flexibility of various formulations to meet specific end-use parameters. The flexibility of the adhesive can be determined at temperatures other than the...

ASTM D3121-2017 “Standard Test Method for Pressure Sensitive Adhesion of Rolling Balls”

Meaning and use 5.1 Ball stickiness testing is quick and easy to operate, with little investment in equipment and little training for operators. This test is primarily used for quality control, as it demonstrates good repeatability in a single laboratory and enables accurate detection of differences between batches if the thickness of the adhesive film remains constant. Rolling ball adhesives are not intended to be used as a research tool because for most pressure-sensitive adhesive applications, rolling ball adhesives results do...

ASTM D3330/D3330M-2018 “Standard Test Method for Peel Adhesion of Pressure Sensitive Tape”

Meaning and use 5.1 These test methods are tools for quality assurance purposes. Given a specific pressure-sensitive tape that is required to have a minimum or maximum stripping value, test data can be used in conjunction with acceptance criteria. 5.2 Test methods A, B, C, E or F may show the relative bonding strength of a given tape with one or more surfaces (materials and textures), compared to standard stainless steel panels. This requirement can be met by replacing standard steel plates...

The plate method thermal conductivity meter can control the temperature quickly and stably

The plate method thermal conductivity meter has many advantages such as large area test sample, multiple types (single material or composite material) test material, high precision temperature control, reliable and stable performance, high degree of control automation, easy operation and so on. Suitable for fire insulation, ceramic fiber, felt, textile, board, brick and other materials at different temperatures of thermal conductivity test. It has many advantages such as large area test sample, multiple types (single material or composite material) test material, high...

This is required for the daily maintenance of the synchronous thermal analyzer

Synchronous thermal analyzer can measure thermogravimetric and differential thermal information synchronously, widely used in ceramics, glass, metal/alloy, minerals, catalysts, energetic materials, plastic polymers, coatings, medicine, food and other fields. The research of synchronous thermal analyzer includes: thermal decomposition of inorganic matter, organic matter and polymer; The corrosion process of metals under high temperature by various gases; Solid state reaction; Calcination and smelting of minerals; Distillation and vaporization of liquids; Pyrolysis processes of coal, oil and wood; Determination of moisture content, volatiles...

Operating procedure and precautions of carbon black analyzer

Carbon black analyzer is an instrument suitable for the determination of carbon black content in polyethylene, polypropylene and polybutene plastics. Operating procedure: 1. Heat the combustion boat to scorching heat, then cool it in the dryer for at least 30min, weigh it, accurate to 0.0001g. The polyethylene sample of (1.0±0.1)g is placed in the combustion boat and weighed together to the accuracy of 0.0001g. The weight of the polyethylene sample is obtained by subtracting the weight of the combustion boat to the...

The characteristics of the use of fast thermal conductivity meter are here

The rapid thermal conductivity meter can be used to test the thermal conductivity of various types of materials. The transient plane heat source method is one of the medium-sized methods to study the thermal conductivity, which makes the measurement technology reach a new level. In the study of materials, the thermal conductivity can be measured quickly and accurately, which provides great convenience for enterprise quality control, material production and laboratory research. The instrument is easy to operate, the method is...