NEWS

ASTM D3941-2020 “Determination of Flash Point by Balance with Closed Cup Apparatus”

Meaning and Purpose 5.1 This test method uses a slow heating rate to provide uniform temperature throughout the specimen. Slow heating rates are required due to low thermal conductivity of certain liquids such as paints, resins, and related products and poor convective heat transfer in products with high viscosity. Since the sample was heated at a reduced rate, a long time interval between each determination was used to re-determine the saturation concentration of steam in the air space above the sample...

Common faults and solutions of constant temperature and humidity test chamber

Common faults and solutions Refrigeration system failure: If the test chamber is unable to maintain the required low temperature, it may be due to a failure of the refrigeration system. At this time, the pressure of the refrigeration system and the supply of refrigerant should be checked, troubleshooting and refilling refrigerant. Failure of the heating system: If the test chamber is unable to maintain the required high temperature, it may be due to a failure of the heating system. At this time,...

Application of flexural stiffness tester in composite materials

The flexural stiffness tester can be used to measure the flexural stiffness and strength of composite materials in composite applications. Composite material is a common material, which is composed of a variety of materials and has the characteristics of light weight, high strength, and high stiffness, which is widely used in aerospace, automotive, construction, and electronics. The flexural stiffness and strength have an important influence on the design and application of composite materials, so the flexural stiffness tester can be...

How to detect the conductivity of lithium battery coating slurry?

The conductivity of lithium battery coating slurry is an important quality index, which is directly related to the performance and life of lithium battery. A common method is to use a conductivity meter for measurement. Procedure of operation The specific operation steps are as follows: Prepare the sample of the coating slurry to be tested and put it into the test cell of the conductivity meter. Calibrate and calibrate the instrument according to the instructions of the conductivity meter to ensure the accuracy of...

The application case of bag lifting fatigue testing machine in garbage vest bag

The application case of bag lifting fatigue testing machine in garbage vest bag The bag carrying fatigue testing machine can be used to test the strength and durability of various plastic bags, including garbage vest bags. Garbage vest bag is a common plastic bag used for garbage collection and disposal. Its strength and durability have an important impact on the process of garbage collection and treatment, so the bag lifting fatigue testing machine can be used to evaluate the strength and...

ASTM D 3278-2021 Determination of Liquid Flash Point with a Small Closed Cup Apparatus

Meaning and Purpose 5.1 Flash point measurement Sample response to heat and ignition source under controlled laboratory conditions. It is only one of many characteristics to be considered when assessing the overall flammability hazard of a material. 5.2 Flash points are used by government regulators in transportation and safety regulations to define and classify flammable and combustible materials. For a precise definition of these classes, see the specific regulations involved. 5.3 Flash points can indicate the possible presence of highly volatile and flammable...

ASTM D 3806-98-2019 “Small-scale Evaluation of Flame Retardant Coatings (2-Foot Tunnel Method)”

Meaning and Purpose 3.1 A number of laboratory procedures are used to evaluate the effectiveness of flame retardant and refractory treatments and coatings. In general, these methods measure three stages of fire development: (1) ignition; (2) Flame spread (the growth rate of the fire); (3) Fire extent. While all three are extremely important, flame spread has been recognized as a major factor relevant for testing flame retardant coatings. 3.2 Flame spread rating based on test method E84 has gained general acceptance from...

ASTM D 4206-96-2018 Test for Continuous Combustion of Liquid Mixtures with a Miniature Cup Opener

Meaning and Purpose 4.1 Mixtures of flammable and non-flammable liquids, such as mixtures of alcohol and water, are classified by the US government according to the definition of flammable liquids based on the closed cup flash point method. Therefore, mixtures can be classified as flammable even if they cannot withstand combustion. This test method determines the ability of a liquid mixture to sustain combustion and, when used in conjunction with the closed cup flash point method, indicates the flammability characteristics of...