A550 alloy analyzer

  • وصف
  • تحقيق

alloy analyzer

A-550 Energy Dispersive X-ray fluorescence spectrometer metal light element component detection analyzer
1. مجال التطبيق:

1.1. ROHS\ halogen free test instruction

1.2. Alloy Analysis field (especially light elements)

Analysis of zinc-aluminum alloy composition

Aluminum alloy composition analysis

Grade determination and composition analysis of copper alloys

Composition analysis of Stainless Steel (Vacuum Light Element Detection)

Analysis of cast iron composition

1.3. Coating composition analysis

Coating thickness analysis

Coating environmental protection testing

A-550 Energy Dispersive X-ray fluorescence spectrometer metal light element component detection analyzer
1.4. Instrument specifications

Instrument cavity size400mmX340mmX80mmThe appearance of the instrument700mmX510mmX336mm
The weight of the instrument56كلغWorking temperature15-30ج
الرطوبة النسبية40% أن لزوجة الطلاء صغيرة جدًا 70%مصدر الطاقةتكييف :220الخامس ± 5 فولت
نطاقات التحليل العنصريfrom sodium (Na) إلى اليورانيوم (يو)Element content analysis rangefrom 1PPm to 99.99%
وقت القياس100-300 ثواني (قابل للتعديل)The energy resolution129±5 إلكترون فولت
The temperature adaptation range15درجة مئوية إلى 30 درجة مئويةمزود الطاقةAC 220V±5V (AC purified and regulated power supply is recommended)

حد الكشف عن العناصر الضارة (limited to Cd/Pb/Cr/Hg/Br/Cl) stipulated in the RoHS directive shall be 1PPM

A-550 Energy Dispersive X-ray fluorescence spectrometer metal light element component detection analyzer
1.7. مواصفات المنتج

1.7.1 A550 is equipped with a vacuum test system to increase the range of element test. The detector is equipped with a test system of SDD to detect various elements between ores and reduce the interference between elements

1.7.2 Overall structured design, beautiful and generous instrument.

1.7.3 The latest SDD silicon drift detector from the United States is adopted, والذي يتم تبريده كهربائياً بدلاً من النيتروجين السائل. لديها حجم صغير, تحليل دقيق للبيانات وتكلفة صيانة منخفضة.

1.7.4 SES signal processing system (digital multi-channel) independently developed is adopted to effectively improve the peak back ratio and make the measurement more accurate.

1.7.5 One-click automatic test, easier to use, more convenient, more user-friendly interface.

1.7.6 سبعة أنواع من نظام موازنة تصحيح المسار البصري, وفقا لعينات مختلفة التبديل تلقائيا.

1.7.7 تصميم متعدد ضد تسرب الإشعاع, the radiation protection level is the Highest of similar products.

1.7.8 Optimize the integrated heat dissipation design to improve the heat dissipation performance of the entire device and ensure the safety of the X-ray source.

1.7.9 Unique movement temperature monitoring technology ensures the safe and reliable operation of the ray source, effectively prolonging its service life and reducing the operating cost.

1.7.10 نظام حماية ملحقات الأدوات المتعددة, ويمكن مراقبتها من خلال البرمجيات, بحيث تعمل الأداة بشكل أكثر استقرارًا وأمانًا.

1.7.11 Special vacuum test software, can choose whether to vacuum, vacuum degree real-time display, تصميم ويندوز القياسي, واجهة ودية, سهل تنفيذه, all control within the click of the mouse.

1.7.12 تعتمد هذه الآلة واجهة USB2.0 لضمان الدقة بشكل فعال, نقل البيانات بسرعة عالية وفعالة.

1.7.13 The unique automatic vacuum system thoroughly shields the influence of air on the light element test, greatly improves the detection limit of light elements, and also expands the detection range.

1.7.14 The integrated vacuum chamber design effectively ensures the vacuum degree that meets the test requirements and improves the maintainability of the equipment.

1.7.15 The conversion between vacuum test and non-vacuum test is simple and convenient for customers to use; At the same time open the cover to remove the vacuum, آمنة, simple and practical.

A-550 Energy Dispersive X-ray fluorescence spectrometer metal light element component detection analyzer
2. The hardware part of the instrument is mainly configured

2.1 SDD electric refrigeration detector:

2.1.1. SDD electric refrigeration detector; دقة: 145±5e electron volts

2.1.2. Amplifier circuit module: detect the characteristic X-ray of the sample; Take the information collected by the probe and enlarge it further.

2.2 X-ray Excitation Device:

2.2.1. Filament current output MAX: 1mA;

2.2.2. It is a semi-lossy part with a service life of more than 5000 ساعات

2.3 High-pressure launcher:

2.3.1. Voltage output MAX: 50ك;

2.3.2. Voltage output MIN: 5ك, controllable adjustment

2.3.3. Equipped with voltage overload protection

2.4 Integrated vacuum system

2.4.1 Vacuum pump system with excellent performance such as low vibration, low noise, self-protection and fast pumping;

2.4.2 Geometric Pumping Speed: 60 L/min (50لقياس اللزوجة المنخفضة للغاية أدناه)

2.4.3 ضغط: 6.7×10-2 Pa

2.5 Digital Multichannel Analyzer:

2.5.1. Convert the collected analog signals into digital signals, and provide the processing results to the upper computer software;

2.5.2 Number of tracks MAX: 4096;

2.5.3 Including signal enhancement processing function;

2.65 Optical Path Filter Module

2.6.1 Reduce the interference in the transmission process of X-ray optical path to ensure the accuracy of detector receiving signals;

2.6.2 Integrate the collimator with the filter;

2.7 Collimator automatic switching module

2.7.1 Up to 7 options, calibers are 8-1 #, 8-2 #, 8-3 #, 8-4 #, 6 #, 4 #, 2 #.

2.8 Filter automatic switching module

2.8.1 Free selection and switching of five filters.

2.9 Free combination module of collimator and filter

2.9.1 Free combination of up to dozens of collimators and filters.

2.10 Automatic selection module of working curve

2.10.1 Automatic selection of working curve, abandon manual selection, avoid human error, automatic and intelligent

The interpretation is more perfect, so that the operation is more human, more convenient.

A-550 Energy Dispersive X-ray fluorescence spectrometer metal light element component detection analyzer
3. برنامج مخصص JPSPEC-FP

3.1.1 مقدمة البرمجيات

Developed specifically for the detection of metal material elements (including vacuum control function), the collected spectral signal data processing, calculation and report the measurement results.

3.1.2 وصف الوظيفة

For different mineral materials adjustable data, measurement time is 100-300 ثواني (قابل للتعديل)

واجهة تشغيل بسيطة وبديهية, سهل الاستخدام, بدون عملية احترافية

3.2 Software interface is shown in the following figure:

1.Suitable calibration curve can be selected automatically, making the measurement more convenient and accurate

2.Chinese and English interface automatically switches, and has the function of third-party language customization

3.أداة المعايرة التلقائية

4.It comes with qualitative analysis of sample material to prevent manual users from choosing wrong curve

5.Print multiple report forms

6.Multiple spectral images can be displayed simultaneously

7.Instrument test parameters and vacuum degree real-time display, all control at a glance

8.Unique movement temperature monitoring technology ensures the safe and reliable operation of the X-ray source, effectively prolongs its service life and reduces the use cost.

A-550 Energy Dispersive X-ray fluorescence spectrometer metal light element component detection analyzer
4. Sample configuration

Standard samples are used to make working curves

4.1 Sample Chamber

Open large sample chamber: 610mm×320mm×100×

Semi-closed sample chamber (vacuum) : Φ100mm×h75mm

4.2 Standard Sample

Silver correction plate

A-550 Energy Dispersive X-ray fluorescence spectrometer metal light element component detection analyzer
5. Standard accessories

Low noise fast pumping vacuum pump

حجم صغير, وزن خفيف, simple structure, easy maintenance and repair

Fast pumping speed, 20S can meet the requirements of vacuum test

Pressure up to 6.7×10-2Pa

Single-phase AC220V power supply without external three-phase power
A550 alloy analyzer A550 alloy analyzer A550 alloy analyzer

اتصل بنا