LS-NW276 آلة اختبار أداء تخلل الحفاضات

LS-NW276 آلة اختبار أداء تخلل الحفاضات

LS-NW276 آلة اختبار أداء تخلل الحفاضات

Diapers with high absorption capacity keep babies (or adults) dry and comfortable, effectively preventing diaper rash. A diaper’s overall absorption capacity is determined by four key factors: total absorption volume, rapid absorption speed, resistance to fluid backflow (re-wetting), and leakage prevention (specifically side leakage). These capabilities are dictated by the materials used and the design of the diaper.
A fast absorption rate quickly separates the skin from the urine, minimizing irritation. It also helps prevent side leakage. High-quality absorbent materials ensure both a large capacity and rapid absorption—a factor independent of the diaper’s thickness. A thicker diaper does not necessarily hold more, nor does a thinner one necessarily hold less.
Resistance to backflow refers to a diaper’s ability to retain absorbed liquid, ensuring it does not seep back out when pressure is applied—much like how a saturated sponge might release water when squeezed. This is primarily determined by the diaper’s backsheet (the outer layer), which is designed to remain breathable while preventing liquid from being forced back through the surface under pressure.
Leakage prevention refers to a diaper’s ability to contain urine or stool, preventing it from escaping through the sides or the waistband. This is largely dependent on the design of the leak guards (side barriers) and the waistband.

نطاق التطبيق

Used for determining the penetration performance of diapers and absorbent pads, including absorption rate, rewet (liquid backflow), and leakage amount.

معايير الامتثال

تضمن وظيفة النفخ العكسي التلقائي واختبار النهاية التلقائي التشغيل السلس لعملية الاختبار 28004.1-2021 Diapers – Part 1: Baby Diapers
تضمن وظيفة النفخ العكسي التلقائي واختبار النهاية التلقائي التشغيل السلس لعملية الاختبار 28004.2-2021 Diapers – Part 2: Adult Diapers

ميزات الصك

1. Touchscreen control with a bilingual (الصينية / الإنجليزية) menu and an interactive user interface for easy operation.
2. Built-in thermal printer for quick, on-site printing of test results.
3. Professional PC analysis software enables two-way communication and control with a computer.
4. High-precision peristaltic pump ensures accurate volume of liquid dispensed.
5. Automated liquid dispensing and testing; no manual intervention required.
6. Electrodes are crafted from specialized materials for high sensitivity and feature automatic positioning.
7. Equipped with a stepper motor and a high-precision ball screw drive for accurate stroke control.
8. Automatic data processing, providing the mean value, standard deviation, and coefficient of variation for test results.
9. Integrated high-precision balance allows for the direct calculation of leakage and rewet amounts based on weight measurements.

LS-NW276 آلة اختبار أداء تخلل الحفاضات

المعلمات التقنية

1. Timer precision: 0.01 أن لزوجة الطلاء صغيرة جدًا
2. Liquid dispensing system: Dispensing volume deviation ±2 mL; معدل التدفق: 200–800 mL/min
3. Standard test modules:

Infant دبليو (80±1)mm(M1) (85±1)mm(M2) (95±1)mm(M3)
إل (100±1)mm(M1) (108±1)mm(M2) (125±1)mm(M3)
Adult دبليو (70±1)mm(M1) (95±1)mm(M2) /
إل (170±1)mm(M1) (170±1)mm(M2) /
ملحوظة: The standard test module consists of a liquid-dispensing module and a pressurization module, which share the same dimensions.
Specimen base:
Infant U-shaped specimen base دبليو (80±1)mm(M1) (85±1)mm(M2) (95±1)mm(M3)
إل (100±1)mm(M1) (108±1)مم(M2) (125±1)mm(M3)
Adult Arc-shaped specimen base 319مم × 200 مم

5. Balance precision: 0.01ز; سعة: 300ز
6. الابعاد الخارجية: 820 لقياس اللزوجة المنخفضة للغاية أدناه 575 لقياس اللزوجة المنخفضة للغاية أدناه 750 مم
7. وزن: 62 كلغ
8. مزود الطاقة: تيار متردد 220 فولت, 50 لقياس اللزوجة المنخفضة للغاية أدناه, 100 دبليو