Dielectric constant tester can provide a general, متعددة الأغراض, اختبار المعاوقة متعددة المدى

Dielectric constant tester is the use of high-frequency resonance method, and provides a general, متعددة الأغراض, اختبار المعاوقة متعددة المدى. The instrument is controlled by a single chip computer, and the measurement core adopts new technologies such as frequency digital locking, الإعداد التلقائي لنقطة اختبار التردد القياسي, resonant point automatic search, نطاق قيمة Q التحويل التلقائي, عرض رقمي, لقطة شاشة QQ 20180731180926A. The tuning loop is improved, so that the residual inductance of the tuning test loop is reduced to a minimum, and the automatic...

How to choose a suitable thermogravimetric analyzer

Thermogravimetric analyzer is an instrument that uses thermogravimetric method to detect the temperature-mass change relationship of substances. Thermogravimetry is to measure the relationship between the mass of a substance and the change of temperature (أو الوقت) under the program temperature control. When the measured material has sublimation, vaporization, decomposition of gas or loss of crystalline water during the heating process, the quality of the measured material will change. Then the TG curve is not straight, it's going down. By analyzing the...

Differential scanning calorimeter is widely used in many fields

المسح التفاضلي للسعرات الحرارية, as one of the common coal laboratory equipment-calorimeter series products, occupies a pivotal position in the whole calorimeter family. مبدأ المسح التفاضلي للسعرات الحرارية هو في الواقع قياس السعرات الحرارية للمسح التفاضلي. The application field of differential scanning calorimeter is extremely wide, على النحو التالي: 1. Determination of thermal stability and antioxidant properties of substances. 2, component analysis of inorganic, عضوي, drug and high 3, chemical reaction research solid material and gas reaction research, قياس أداء المحفز, أبحاث حركية التفاعل,...

تعرف على كل شيء عن جهاز قياس التوصيل الحراري السريع

يعتمد مضيف اختبار التوصيل الحراري السريع على وحدة تيار ثابتة عالية الثبات وعالية الدقة. الغلاف المعدني أبيض للكمبيوتر, شكل الغلاف الجوي, عملية الإنسانية, هيكل مدمج. شاشة LCD ملونة, عملية اللمس. يمكن أن يؤدي وقت حماية النظام الإلزامي إلى إطالة عمر خدمة الجهاز بشكل كبير. ميزات الصك: 1. نطاق اختبار واسع, أداء اختبار مستقر, في الصكوك المحلية المماثلة, في مستوى الأولوية; 2. القياس المباشر, يمكن ضبط وقت الاختبار من 5 إلى 160 ثانية أو نحو ذلك, يمكن بسرعة ...

ASTM D1455-2017 “Standard Test Method for 60° Specular Gloss of Latex Floor Polish”

المعنى والاستخدام 4.1 When measuring light reflected at an Angle of 60°, the test method can be used to evaluate the gloss difference of the dry film of the emulsion floor polish. High gloss or low gloss polishes may not be distinguishable at 60° angles. The A20 ° Angle measured according to test method D523 can give a better definition of gloss. ASTM D1455-2017 "Standard Test Method for 60° Specular Gloss of Latex Floor Polish" نِطَاق 1.1 The test method...

ASTM F1843-2015 Standard Practice for Preparation of Plastic Film Samples Using Film Switch Covers for Specular Gloss Measurement

المعنى والاستخدام 5.1 Gloss measurement is used to identify raw materials or finished products. 5.2 Sample preparation will affect the results of the gloss reading. This practice will eliminate the second surface reflection and allow a more accurate reading of the gloss of the substrate. 5.3 Materials required for this preparation include transparent or translucent substrates, colored transparent substrates and areas printed with transparent, translucent or transparent colored coatings. ASTM F1843-2015 Standard Practice for Preparation of Plastic Film Samples Using Film Switch Covers...

أستم D4587-2019 “الممارسة القياسية للتعرض للأشعة فوق البنفسجية لتكثيف الفلورسنت للطلاءات والطلاءات ذات الصلة”

المعنى والاستخدام 4.1 قدرة الطلاء أو الطلاء على مقاومة تدهور الخصائص الفيزيائية والبصرية الناتجة عن التعرض للضوء, حرارة, والماء مهم للعديد من التطبيقات. تم تصميم هذه الممارسة لإحداث اختلافات في الأداء تتعلق بظروف الاستخدام النهائي, بما في ذلك آثار ضوء النهار, رُطُوبَة, والحرارة. لا يهدف التعرض المستخدم في هذه الممارسة إلى وضع نموذج للتدهور الناجم عن ظواهر الطقس المحلية مثل تلوث الغلاف الجوي, هجوم بيولوجي, والتعرض للمياه المالحة. 4.2 Warning-Results may...

ASTM D1310-2014 “Test Method for the Determination of Flash and Ignition Points of Liquids Using the Tiger Open Cup Device”

المعنى والاستخدام 5.1 The flash and ignition points of a liquid are physical characteristics that can be used to define its flammability hazard. Flash points can be used to classify materials in government regulations. ASTM D1310-2014 "Test Method for the Determination of Flash and Ignition Points of Liquids Using the Tiger Open Cup Device" نِطَاق 1.1 The test method covers the method of determining the flash and ignition points of liquids with flash points from -18 to 165°C (0 to 325°F) and up...