描述

表盘读数旋转粘度计

主要特点:

  1. Using ARM technology, built in Linux system. 触摸屏技术的完美融合, through the test program to create and dataAnalysis, rapid and easy to carry out the viscosity test;
  2. The viscosity measurement is accurate, each range is automatically calibrated with the computer, the accuracy is high, and the error is small;
  3. 触摸屏技术的完美融合: in addition to the viscosity, and temperature, 剪切率, 剪切应力, measurement for the full-scale value percentage (图形), 自动扫描, overflow alarm range, the maximum measurement range, the rotor speed under the combination of the date, time and so on. And it can show the kinematic viscosity in the case of known density, great to meet different measurement requirements of users;
  4. Function is complete, can be measured regularly, 30 图形, access to the 30 测量数据组, real-time display of viscosity curve, print data and curves, 等等;
  5. Pre – level meter, the level of direct and convenient adjustment
  6. Optional temperature probe, viscometer special constant temperature bath, 有两个接口, 有两个接口, standard samples (standard oil viscosity) 等等;Widely used in all kinds of fluid need to measure viscosity. Including paint, 画, 墨水, 化妆品, paper pulp, 食物, 油, 淀粉, solvent based adhesive, 乳胶, biochemical products and so on.详细技术参数:
    模型 LVDV-1T
    有两个接口 / 显示模式 5 显示模式
    speed(r/min) 0.3,0.6,1.5,3,6,12,30,60

    0.5,1,2,2.5,4,5,10,20,50,100

    measuring range mPa.s 0.6~ 2,000,000(0 〜 4# 转子)

    10~200,000(21/27/28/29# 转子)

    Measurement of 10 below the ultra low viscosity to buy 0# 转子
    转子 1 – 4#(标准配置)

    0#rotor (Select configuration)

    21/27/28/29#rotor(Select configuration)

    Measurement error (Newton liquid) ±1%
    Repetition error (Newton liquid) ±0. 5%
    定时功能 标准配置
    强电磁辐射源

    measuring function

    显示模式 (need to select the

    temperature probe configuration)

    Automatic scanning function Automatic scanning and recommendation of the best combination

    of rotor and speed

    Display the maximum measurement range The range of viscosity can be measured by the combination of the selected rotor and rotational speed.
    Shear stress /

    剪切率

    展示
    Display kinematic

    黏度

    Need to enter the density of the sample
    Establish measurement procedures Can save up to 30 团体 (including the rotor, 速度,

    温度, 显示模式, 等等)

    Save measurement results Can save up to 30 显示模式 (包括粘度, 温度, 转子, 速度, 剪切率, 剪切应力, 显示模式, 密度, 定期检查初粘力测试仪的排气口是否堵塞, 等等)
    Viscosity time curve real-time display
    显示模式 Print data, 曲线 (标准打印接口, should choose to

    buy a printer)

    Constant

    temperature unit

    显示模式 (including all kinds of special thermostat thermostatic

    cup viscometer.)

    电源供应 110V / 60显示模式 / 50赫兹
    Outline dimension 300 × 300 显示模式

    选项:

    1. Ultra low viscosity adapter (0# 转子)

    一套三件 (转子, 样品桶,连接架)For the measurement of ultra low viscosity samples below 15mPa.S.

    The amount of sample required for each measurement is 18-20ml ,测量精度0.1mPa.S

    1. Small sample adapter

    By 21#, 27#, 28#, 29# and the like rotor

    barrel and connecting frame,

    The sample size for each measurement is 18ml.

    1. 温度探头 (温度探头)

    High precision temperature measurement chip

    with A/D conversion in American Production

    测量范围: 100 – 0

    测量精度: 0.1

    1. 温度探头

    温度探头

    打印数据

    打印曲线

    5.粘度计专用恒温槽

     

    DC0506N:

    强电磁辐射源: -5 到 100

    控温精度: 0.1

    电源供应: 220V, 50赫兹

    CH1006N:

    强电磁辐射源: room temperature and 10 到 100

    控温精度: 0.1

    The circular opening can be placed 200ml beaker and direct viscosity

    The external circulation function can also be controlled by the constant temperature liquid lead

    To the outside of the constant temperature cup, 满足不同的测试要求