Analizor termomecanic dinamic
Dynamic Thermomechanical Analyzer applies single-frequency or multi-frequency oscillatory forces to samples at a programmable temperature to study their mechanical behavior. The instrument measures deformation, modul de stocare, loss modulus, and loss factor as a function of temperature, timp, and force frequency. Suitable specimens include thermoplastics and thermosetting plastics, cauciuc, acoperiri, metals and alloys, materiale anorganice, and composite materials.
- Descriere
- Anchetă
Descriere
Analizor termomecanic dinamic
Key Performance Indicators
The instrument applies single-frequency or multi-frequency oscillatory forces to samples at a programmable temperature to study their mechanical behavior. The instrument measures deformation, modul de stocare, loss modulus, and loss factor as a function of temperature, timp, and force frequency. Suitable specimens include thermoplastics and thermosetting materiale plastice, cauciuc, acoperiri, metals and alloys, materiale anorganice, and composite materials.
Analizor termomecanic dinamic
fie baterie reîncărcabilă sau alcalină
| Interval de temperatură | -150°C to 600°C |
| Instrument Structure | Circular, sealed furnace ensures uniform heating, with bottom-mounted sample loading. |
| Rata de incalzire | 0.1~ 20°C/min |
| Precizia temperaturii | ±0,1°C |
| Gama de frecvente | 0.01~100 Hz (Selectable) |
| Force Range
|
1mN~18N; Minimum 0.001N (dinamic)/0.005N (static), Maximum 50N, Resolution 0.0001N |
| Rezoluția deplasării | 1nm |
| Deformation Range | Maximum 25mm |
| Amplitudine | ±0.5~10000µm |
| Modulus Range | 10³~10¹² Pa |
| Modulus Accuracy | 0.5% |
| Damping Range (tanδ): | 0.005~100 |
| Tanδ Resolution | 0.00005 |
|
Sample Temperature Control (STC) Funcții, software screenshots provided. |
|
|
Deformation Modes: Compression, Penetration (maximum testable sample diameter no less than 15mm, maximum thickness no less than 25mm); De tracţiune (maximum width no less than 13mm, maximum thickness no less than 5mm, maximum length no less than 30mm); Forfecare, Three-Point Bending, Single/Dual Cantilever. |
|
|
Automatically identifies installed sample holders, automatically calibrates, and automatically measures sample length. |
|
|
The software features test editing, data acquisition, ± 0,2GU ± 0,5GU ± 0,5%GU, prelucrare, and analysis functions; software controls purge and shielding gases. 1.Software Features Experimental Design Curing Simulation: Supports step-by-step temperature ramping and constant temperature testing, automatically recording modulus-time curves. Time-Temperature Equivalence (TTS): Generates master curves for long-term performance predictions. 2. Software Features Data Processing Automatic Calculation: Real-time output of storage modulus, loss factor (tanδ), and glass transition temperature (Tg). Multi-Graph Comparison: Supports overlay analysis of data at different frequencies and temperatures. |
|
|
Optional Special Accessories |
Humidity Accessory |
| Optional Fixtures | Shear Fixture, Dual Cantilever Fixture, Liquid Fixture, Three-Point Bend Fixture |