Analizor automat de stabilitate a oxidării uleiului
The LS-ST200 Fully Automatic Oil Oxidation Stability Analyzer (OSI (Oxidative Stability Index)) is designed and manufactured strictly according to GB/T21121-2007 Determination of Oxidative Stability of Animal and Vegetable Oils (Accelerated Oxidation Test). It features single-chip microcomputer control, an LCD display, and automatic result output and printing.
- Descriere
- Anchetă
Descriere
Analizor automat de stabilitate a oxidării uleiului
Descriere:
The LS-ST200 Fully Automatic Oil Oxidation Stability Analyzer (OSI (Oxidative Stability Index)) is designed and manufactured strictly according to GB/T21121-2007 Determination of Oxidative Stability of Animal and Vegetable Oils (Accelerated Oxidation Test). It features single-chip microcomputer control, an LCD display, and automatic result output and printing.
During the OSI (Oxidative Stability Index) Test, air is introduced into an oil sample at a specific temperature and flow rate to accelerate the oxidation of glycerol fatty acid esters, producing volatile organic acids. The air carries these volatile organic acids into a conductive chamber, where water dissolves them, ionizing them and altering the water’s conductivity. A computer continuously measures the conductivity of the conductive chamber. A sharp increase in conductivity indicates the end of the induction period; the time before this end is called the OSI time.
The single-chip microcomputer control also allows for the plotting of sample-time conductivity curves and automatic calculation of the oil oxidation stabilization time. The instrument itself includes a sample measurement switch and status display.
Main Application Areas
Vegetable Oils: Soybean oil, sunflower oil, rapeseed oil, palm oil, peanut oil, etc.;
Animal Oils: Butter, ulei de peste, lard, etc.;
Oil-Containing Products: Cosmetice, margarine (direct determination), cereal products, biscuits, nuts, smoked meat, sausages, carne, etc.. (determined after oil extraction);
Research on the antioxidant properties of antioxidants;
Determination of the oxidative stability of FAME (fatty acid methyl esters);
Determination of the oxidative stability of light oils using copper catalysts
Analizor automat de stabilitate a oxidării uleiului
fie baterie reîncărcabilă sau alcalină
GB/T21121-2007 Determination of oxidative stability of animal and vegetable oils (accelerated oxidation test)
ISO 6886-2006 Animal and vegetable oils—Determination of oxidative stability (accelerated oxidation test)
2.4.28.2-93 Natural oxidative stability test of fats (CDM, Japonia)
Dedicated diaphragm pump, precise flow control, constant flow rate
Real-time measurement data using a conductivity meter.
Data Display: Real-time display of the conductivity during the oil oxidation process and induction period.
The length of the induction period represents the stability of the oil.
Metoda de afișare: 7-inch color LCD display;
Metoda de încălzire: Metal bath heating.
Temperature Sensor: Imported Pt 100 senzor de temperatură;
Storage Method: 1999 sets of historical data can be stored for easy retrieval;
Result Output: Also equipped with USB flash drive output function for long-term data storage on a PC;
Output Format: Results are output to the USB flash drive in CSV or Excel format; Can be used for standalone touchscreen experiments or computer-controlled experiments.
Heating Module: Can heat a single or multiple heating elements; heating temperature can be set individually for each heating hole.
Input Extension: Option to input sample number and other information via barcode scanning (opțional); Equipped with dedicated calculation software to automatically calculate oxidation stabilization time.
Instrument Display: The instrument features a color display screen showing the temperature of each heating module, gas flow rate, measurement cell status, and conductivity value at each measurement point.
Heating Modules:
Metoda de încălzire: Metal bath heating
Volumul probei: 3± 0,2GU ± 0,5GU ± 0,5%GU (National standard recommended dosage)
Interval de control al temperaturii: Temperatura camerei~220℃
Precizia controlului temperaturii: ±0,1℃
Protection Function: Over-temperature protection function; automatically stops when the temperature exceeds 260℃.
Metoda de control al temperaturii: Four temperature groups can be controlled independently; all four groups can be set to the same temperature or different temperatures.
Gas Flow Control Module:
Built-in diaphragm air pump
Dedicated electronic air flow pump
Air Flow Range: 1~30 L/h (25℃, normal atmospheric pressure) 101.325kPa
Conductivity Measurement System:
Conductivity Measurement Range: 0~300uS/cm (0-500uS/cm)
Conductivity Resolution: 0.1 US/cm
Software Calculation Module:
Possesses a powerful database data management system; can automatically calculate oxidation stabilization time.
Automatically calculates the maximum value of the second derivative of the curve to determine the induction time. Automatically derives the induction time for samples at room temperature (20°C or 25°C).
Dimensiuni: 420*390*480mm.
Greutate: Packaging dimensions: 560×400×530mm. Greutate: 26kg
Lista de ambalare:
| Nu. | Nume | Cantitate | Note |
| 1 | Oil Oxidation Stability Analyzer | 1 | |
| 2 | Calculator | 1 | You may bring your own |
| 3 | Reaction Cell | 4 | |
| 4 | Reaction Cell Plug | 4 | |
| 5 | Measuring Cell | 4 | |
| 6 | Dop pentru celule de măsurare | 4 | |
| 7 | Tub de ventilație | 1 | |
| 8 | Senzor de conductivitate | 4 | |
| 9 | Filtru de gaz | 1 | |
| 10 | Accesorii de conectare a tubului de ventilație | 1 | |
| 11 | Software de calcul al analizorului de stabilitate a oxidării uleiului | 1 | |
| 12 | Cablu de alimentare | 1 |