Características
1 ,The photoelectrical technique is adopted, with a precision grating rule as a measurer for X- and Y-axle as a measurer, with readings direct-viewing and testing convenient.
2 ,The photoelectrical technique is adopted, with a precision grating rule as a measurer for X- andY-axle and a numbering device as a measurer for the rotary working table, to realize the length andangle full-display; with readings direct-viewing and testing convenient.
3 ,With multiple eyepieces and objectives,the main microscope has a large scope ofview field with clear image formation.
4 ,The main microscope can oscillate left and right, suitable for the measurement for spiral parts.
5 ,LED-luminotron lighting is adopted for transmission and indirect lighting, with low heating power and long life.
6 ,High-speed and micro-motion devices are adopted; which can be switched over quickly.
7 ,The tailstock rack is installed to measure the axel-type parts.
8 ,Multiple accessories are provided, with extensive uses.
Microscópio digital para fabricantes de ferramentas em grande escala JX14B
Parâmetros técnicos
1 ,Mesa de trabalho
1.1Measuring stroke of the coordinate
X-coordinate: 150mm Y-coordinate: 75milímetros
1.2Measuring resolution ratio of X- and Y-coordinate: 0.001milímetros
1.3Accuracy of the instrument: (2+L/50)μm, of which, L = measured length ( unidade: milímetros)
1.4Diameter of the circular worktable:
Φ190mm(vidro) Φ280mm(metal)
1.5Angular calibrated range of the circular worktable: 0°~ 360°
1.6Measured-angle resolution ratio of the circular worktable: 3 ′
2 ,Microscope upright column
2.1Sloping scope: ±12°
2.2Calibrated value of the slope angle: 30′
3 ,Goniometric eyepiece
3.1Angular calibrated range: 0°~ 360°
3.2Angular calibrated value: 1 ′
4 ,Template eyepiece
4.1Calibrated range of the template eyepiece: ±7°
4.2Angular calibrated value of the template eyepiece: 10 ′
5 ,Optical detector
5.1Minimum detective hole diameter of the optical detector: Φ5mm
5.2Maximum detective depth of the optical detector: 15milímetros
5.3Measuring power: 0.1N
6 ,Tailstock Frame
6.1Diâmetro máximo de fixação: Φ70mm
6.2Comprimento máximo de fixação: 190milímetros
7 ,Âmbito de aplicação
|
Âmbito de aplicação ampliação |
Bruto ampliação m³/min |
Objeto funcionando distância (milímetros) |
Visual do objeto campo (milímetros) |
|
1Incluindo vários tipos de tubos cosméticos |
10Incluindo vários tipos de tubos cosméticos |
79 |
Φ20 |
|
3Incluindo vários tipos de tubos cosméticos |
30Incluindo vários tipos de tubos cosméticos |
69 |
Φ6,7 |
|
5Incluindo vários tipos de tubos cosméticos |
50Incluindo vários tipos de tubos cosméticos |
49 |
F4 |
8 ,Peso máximo da peça do rolamento pelo instrumento: 20kg
9 ,Tamanhos gerais do mainframe do instrumento (milímetros): 720×460×600
10 ,Peso do mainframe: 100 kg
11 ,Suporte tipo V
Diâmetro máximo permitido de uma peça de trabalho: 130milímetros