Microscópio digital para fabricantes de ferramentas em grande escala JX14B

Descrição

Microscópio digital para fabricantes de ferramentas em grande escala JX14B

Características

1 ,The photoelectrical technique is adopted, with a precision grating rule as a measurer for X- and Y-axle as a measurer, with readings direct-viewing and testing convenient.

2 ,The photoelectrical technique is adopted, with a precision grating rule as a measurer for X- andY-axle and a numbering device as a measurer for the rotary working table, to realize the length andangle full-display; with readings direct-viewing and testing convenient.

3 ,With multiple eyepieces and objectives,the main microscope has a large scope ofview field with clear image formation.

4 ,The main microscope can oscillate left and right, suitable for the measurement for spiral parts.

5 ,LED-luminotron lighting is adopted for transmission and indirect lighting, with low heating power and long life.

6 ,High-speed and micro-motion devices are adopted; which can be switched over quickly.

7 ,The tailstock rack is installed to measure the axel-type parts.

8 ,Multiple accessories are provided, with extensive uses.

Microscópio digital para fabricantes de ferramentas em grande escala JX14B

Parâmetros técnicos

1 ,Mesa de trabalho

1.1Measuring stroke of the coordinate

X-coordinate: 150mm Y-coordinate: 75milímetros

1.2Measuring resolution ratio of X- and Y-coordinate: 0.001milímetros

1.3Accuracy of the instrument: (2+L/50)μm, of which, L = measured length ( unidade: milímetros)

1.4Diameter of the circular worktable:

Φ190mm(vidro) Φ280mm(metal)

1.5Angular calibrated range of the circular worktable: 0°~ 360°

1.6Measured-angle resolution ratio of the circular worktable: 3 ′

2 ,Microscope upright column

2.1Sloping scope: ±12°

2.2Calibrated value of the slope angle: 30′

3 ,Goniometric eyepiece

3.1Angular calibrated range: 0°~ 360°

3.2Angular calibrated value: 1 ′

4 ,Template eyepiece

4.1Calibrated range of the template eyepiece: ±7°

4.2Angular calibrated value of the template eyepiece: 10 ′

5 ,Optical detector

5.1Minimum detective hole diameter of the optical detector: Φ5mm

5.2Maximum detective depth of the optical detector: 15milímetros

5.3Measuring power: 0.1N

6 ,Tailstock Frame

6.1Diâmetro máximo de fixação: Φ70mm

6.2Comprimento máximo de fixação: 190milímetros

7 ,Âmbito de aplicação

Âmbito de aplicação

ampliação

Bruto

ampliação

m³/min

Objeto funcionando

distância

(milímetros)

Visual do objeto

campo

(milímetros)

1Incluindo vários tipos de tubos cosméticos

10Incluindo vários tipos de tubos cosméticos

79

Φ20

3Incluindo vários tipos de tubos cosméticos

30Incluindo vários tipos de tubos cosméticos

69

Φ6,7

5Incluindo vários tipos de tubos cosméticos

50Incluindo vários tipos de tubos cosméticos

49

F4

8 ,Peso máximo da peça do rolamento pelo instrumento: 20kg

9 ,Tamanhos gerais do mainframe do instrumento (milímetros): 720×460×600

10 ,Peso do mainframe: 100 kg

11 ,Suporte tipo V

Diâmetro máximo permitido de uma peça de trabalho: 130milímetros