LS-3520 Moisture Analyzer

Categories:

  • Description
  • Inquiry

LS-3520  Moisture Analyzer

Use

Rapid moisture tester, its operation is simple, easy to observe and with its excellent performance is fully used in food, tobacco, pharmaceutical, oil, paper making, feed, chemical industry, coating, mining, environmental protection, geology and other industries for rapid determination of moisture content of material, at the same time meet the solid, particles, powder, gel body and liquid moisture content measurement requirements

 

LS-3520  Moisture Analyzer

Features:

1.Fast and uniform halogen lamp heater with innovative SRA technology

A straight halogen lamp and a specially designed SRA (secondary radiation assist device) radiator are used to shorten the measurement time and form a fast and uniform heater.

2.High accuracy

The use of SHS quick and sensitive characteristics of the weight sensor, so that very few samples in the high-precision weighing can be very accurate determination of moisture content.

3.Sodium tartrate dihydrate is used as the standard for measuring water content accuracy

Sodium tartrate dihydrate is a chemical substance with a stable moisture content of 15.66% 0.3/-0.1, so it is most reliable for precision inspection and provides reference value for the tester.

4.Heater temperature calibration (MS/MX only)

Optional temperature calibrator, calibration results can be output in the format of GLP, GMP, ISO.

5.Standard winct-moisture software (MS/MX only) for real-time graphic display

Winct-moisture Moisture software is a Moisture content analysis software specially designed for graphic display, which can show the graph of Moisture content change during measurement and can set the measurement program of different samples by computer aided analysis according to the graph.

6.Measurement procedures, measurement results storage function

Up to 20 sets of measurement procedures can be stored, and different measurement procedures can be called at any time according to different samples for moisture content determination. Therefore, rapid measurement can be realized and operation errors can be avoided (MF can store up to 10 groups and ML can store up to 5 groups).The measurement results can be stored in 100 groups (MF 50 groups,ML 30 groups) and output by computer or printer, completely avoiding human error.

7.Comply with GLP/GMP/GCP and ISO standards, with date/time, ID, calibration data and test record output

Ability to record and output calibration and measurement data to meet quality management and certification requirements.

8.Standard rs-232 interface

Communicate with PC or connect to printer.

9.Large screen fluorescence display with clear and easy to observe

The measurement procedure, set value, moisture content change rate, measurement status, data number and other important information are clearly displayed at the same time.

10.The parts are easy to operate

Ergonomically designed disc handle to avoid accidents such as burns when hot samples are placed or removed. Wing handle makes heating cover easy to open and close.

11.Guarantee of low maintenance cost

Users do not need to stop using when replacing the halogen lamp, and the small room with protection is easy to clean (the life of the halogen lamp is about 5000 hours).

12.Five measurement procedures

Standard mode: automates measurement by setting high, medium and low measurement accuracy.

Automatic mode: when the rate of moisture change is less than a set ratio, the measurement will be automatically ended.

Fast mode: in order to realize rapid determination to start the first 3 minutes with 200 ℃ heating, then according to the set to complete the measurement automatically.

Timing mode: the measurement is completed by setting the duration.

Manual mode: operate the measurement process by pressing the start and stop buttons.

13.Four drying procedures

Standard drying: directly raise the temperature to the set temperature after starting.

Asymptotic drying: gradually rising to the set temperature after a preset time.

Step drying: adopt different temperature according to time.

Quick drying: 200 ℃ rapid heating after 3 minutes based on continuous heating drying temperature setting.

Any combination of measurement procedure and drying procedure can fully meet the determination requirements of different samples.

 

LS-3520 Moisture Analyzer

Options:

Ax-mx-31 sample tray (100 PCS)

Ax-mx-32-1 glass fiber sheet (diameter: 70mm,100 sheets)

Ax-mx-32-2 glass fiber sheets (diameter: 78mm 100 sheets)

Ax-mx-33 test sample (30 g sodium tartrate dihydrate,12 pieces)

Ax-mx-34 halogen lamp tube (ac200-240v)

Ax-mx-40 rs-232 cable (2 m, 25 to 9 stitches)

Ax-mx-41 calibration weight (20 g,OIML)

Ax-mx-43 temperature calibrator (MS/MX only)

 

LS-3520  Moisture Analyzer

Specification

ModelLS-3520-70LS-3520-50LS-3520-50
Test methods400W straight tube halogen lamp heating system with SRA radiator and SHS weighing technology
Sensor typeSHS sensor
Weighing scale71g51g51g
Weighing accuracy0.0001g0.001g0.002g
Humidity display accuracy0.001%0.01%/0.1%0.01/0.1%0.05/0.1/1%
Humidity accuracy> 1g0.05%0.10%0.20%
> 5g0.01%0.02%0.05%
Heater technologyHalogen lamp (straight tube, Max. 400W,5000 hours)
Drying temperature30-200℃50-200℃
Measuring program20groups10groups
Measuring wayStandard/automatic comparison/timing/manual
Humidity display modeRelative humidity/absolute humidity/dry-wet ratio/wet-dry ratio
Display typeLarge screen fluorescence display
ConnectorRS-232
Data storage function100groups50groups
Operate environment5-40℃,less than 85%RH
GLP/GMP/ISOStandard function
Self-checking functionstandard
Communication softwareWinCT-Moisture standard softwareWinCT standard software
Sample tray size     Diameter 85MM(optional 110mm)
PowerAC100-120V or AC200-240V,50/60Hz about 400W
External dimensions/weight215x320x173/about 6kg
Standard accessories20 sample plates,2 disk handles, photo, sample keys, test samples, cd-rom, display film, dust cover, user manual, quick access card, power cord, two fuses.

 

Contact Us