- Opis
- Zapytanie ofertowe
Miernik grubości powłoki TT270
Wstęp
The Times TT270 thickness gauge is a portable measuring instrument, which can measure the thickness of coating and coating rapidly and precisely without damage.It can be used in both laboratory and engineering field.Through the use of different probe, can meet the needs of a variety of measurement.Scope of era TT270 thickness gauge using both the magnetic and eddy current thickness method, measuring magnetic metal substrate condition (such as steel, iron, alloy and hard magnetic steel, itp.) on the magnetic coating thickness (such as aluminum, chromium, miedź, szkliwo, itp.), guma, paint and nonmagnetic metal substrate (such as copper, aluminium, zinc, tin, itp.) on the conductive layer thickness.
Miernik grubości powłoki TT270
Character and function
Using both magnetic and eddy current thickness method, and F type measuring head without damage to the measurement of magnetic metal basic body of magnetic coating thickness (such as steel, iron, zinc alloy and hard magnetic steel, aluminium, chromium, miedź, guma, farba, itp.), and N type measuring head without damage to the measurement of non-magnetic thickness of the conductive coating on metal substrates (such as copper, aluminium, zinc, tin and other metal oxide film of paint, guma, Plastikowy, itp.)
Can use 6 kinds of measuring head / 90 ° F400, F1, F1, F10, N1, CN02
Two measurement methods: CONTINUE and SINGLE
Two ways of working: DIRECT and group (APPL)
There are five statistics: MEAN, larger (MAX), MIN, number of tests (NO.), and standard deviation (S.DEV).
Two methods can be used to calibrate the instrument
Chinese and English menu display, operation more intuitive and convenient
Liquid crystal display has backlighting function
It can store 640 możesz zwiększyć prędkość liniową i jakość produktu, aby osiągnąć wydajną produkcję
With delete function, delete single or all data measured
Print function
With integrated printer, łatwy w użyciu
Power supply undervoltage indication
The operation process is beeping (single measurement method)
Error message function
Manual and automatic shutdown functions
Miernik grubości powłoki TT270
TT270 thickness gauge head selection table is as follows:
Probe model | F400 | F1 | F1/90° | F10 | |||
Work Theory | Magnetic induction | ||||||
Test range(um) | 0~400 | 0~1250 | 0~10000 | ||||
Low resolution(um) | 0.1 | 0.1 | 10 | ||||
Value error | One point calibration(um) | ±(3%H+1) | ±(3%H+10) | ||||
Two point calibration(um) | ±[(1~3) %H+0.7] | ±[(1~3)%H+1] | ±[(1~3)%H+10] | ||||
Test conditions
| Minimum radius of curvature(um) | convex | 1 | 1.5 | płaski | 10 | |
The diameter of the smallest area(mm) | 3 | 7 | 7 | 40 | |||
Critical matrix thickness(mm) | 0.2 | 0.5 | 0.5 | 2 | |||
Probe model | N1 | CN02 | |||||
working principle | Eddy current | ||||||
Measuring range(um) | 0~1250 | 10~200 | |||||
Low resolution(um) | 0.1 | 1 | |||||
Value error | One point calibration(um) | ±(3%H+1.5) | ±(3%H+1) | ||||
Two point calibration(um) | ±[(1~3) %H+1.7] | — | |||||
test conditions
| Minimum radius of curvature(um) | 3 | Only for flat | ||||
The diameter of the smallest area(mm) | 5 | 7 | |||||
Critical matrix thickness(mm) | 0.3 | unlimited |