AKTUALNOŚCI

Still don’t know what is a dielectric constant tester? Look right here

The dielectric constant tester is used to measure the dielectric constant of different concentrations of solutions. It is composed of precision digital bridge, test device, standard medium sample, and can test the dielectric loss value (D or tanδ) and dielectric constant (mi) of high and low frequency insulating materials. It is used in research institutions, szkoły, factories and other units to study the application of inorganic metal new material properties. Co to jest stała dielektryczna? The dielectric constant (Dk) of a plastic or...

ASTM B578-2015 Standardowa metoda badania mikrotwardości powłok galwanicznych

abstraction This test method specifies the determination of the microhardness of metal coatings on various substrates (powłoki galwaniczne). Pomiarów dokonuje się za pomocą wgłębnika Knoopa pod określonymi obciążeniami testowymi, a twardość podaje się jako wartość twardości Knoopa (HK). To podsumowanie stanowi krótki przegląd standardów referencyjnych. Służy wyłącznie celom informacyjnym i nie stanowi oficjalnej części normy; Aby zapoznać się z jej wykorzystaniem i zastosowaniem, wymagane jest odniesienie do pełnego tekstu samej normy. ASTM makes...

ASTM B571-2018 Standardowa praktyka dotycząca jakościowego badania przyczepności powłok metalowych

Standardowa praktyka ASTM B571 dotycząca jakościowego badania przyczepności powłok metalowych obejmuje proste czynności, badania jakościowe służące do oceny przyczepności powłok metalowych do różnych substancji. Znaczenie i zastosowanie 2.1 Testy te są przydatne do kontroli produkcji i testów akceptacyjnych produktu. 2.2 Interpretacja wyników jakościowych metod określania przyczepności powłok metalowych jest często przedmiotem dyskusji. Jeśli używanych jest wiele testów, niezaliczenie któregokolwiek z nich uważa się za niezadowalające. W wielu przypadkach, the end use of the...

ASTM B568-2014 Standard Test Method for Measurement of Coating Thickness by X-ray Spectroscopy

Znaczenie i zastosowanie 5.1 This is a sensitive, non-contact and non-destructive method for measuring the coating thickness (i, w niektórych przypadkach, coating composition) of metals and some non-metallic coatings, począwszy od 0.01 microns to 75 mikrony, depending on the coating and base material. It can be used to measure coating and alkali combinations that are not easily measured by other techniques. 5.2 Coating thickness is an important factor in coating performance in use. ASTM B568-2014 Standard Test Method for Measurement of Coating Thickness...

ASTM B567-2014 Standard Test Method for Measurement of Coating Thickness by Beta Backscatter Method

Znaczenie i zastosowanie 4.1 The thickness or quality per unit area of the coating is usually of no importance to its performance. 4.2 For some coating to substrate combinations, the beta backscatter method is a reliable method for measuring coatings non-destructively. 4.3 If the mass per unit area is specified, the test method applies to the thickness specification acceptance. If the coating thickness is specified and the density of the coating material can vary or is not known, it is not suitable for...

ASTM B556-2018 Standard Guide for Measurement of Thin Chromium Coatings by Spot Test

Znaczenie i zastosowanie 4.1 The thickness of the decorative chrome coating is generally important to its performance. 4.2 This procedure can be used for approximate determination when good accuracy is not required. For a more reliable determination, można zastosować następujące metody: Methods B504, B568 and B588. 4.3 This test assumes that hydrochloric acid dissolves chromium at the same rate under certain conditions. ASTM B556-2018 Standard Guide for Measurement of Thin Chromium Coatings by Spot Test Step 1: Zakres 1.1 This guide includes the use...

Zasada i budowa wysokotemperaturowego różnicowego analizatora termicznego

High temperature differential thermal analyzer is a thermal analytical instrument that tests the thermal effect of substances in the process of heating or cooling, które mogą badać związek między szybkością zmian fizycznych i chemicznych substancji a temperaturą, a także charakterystyka niektórych właściwości fizycznych i chemicznych substancji pod wpływem ciepła. The functional relationship between the temperature difference and the temperature between the substance and the reference substance can also be measured under...

Co mierzy analizator termograwimetryczny? Jakie są obszary zastosowań

W celu lepszej poprawy jakości produktów, musimy testować i analizować surowce, szczególnie w branżach takich jak żywność, leki i powłoki. dobry czas tłumienia huśtawki jest długi, analizator termograwimetryczny, jako rodzaj przyrządu wykorzystującego metodę termograwimetryczną do wykrywania zależności pomiędzy temperaturą a jakością substancji, jest szeroko stosowany w tych gałęziach przemysłu, i w dużej mierze przyczynił się do szybkiego rozwoju branży analizatorów termograwimetrycznych. Obecnie, na rynku dostępnych jest wiele marek analizatorów termograwimetrycznych..