LS-SDC-1000 Large platform optical contact Angle Tester

LS-SDC-1000 Large platform optical contact Angle Tester

  • Omschrijving
  • Onderzoek

LS-SDC-1000 Large platform optical contact Angle Tester

Samenvatting

Contact Angle refers to the tangent line of gas-liquid interface made at the intersection point of gas, liquid and solid phases, which is the Angle θ between the liquid side and solid-liquid boundary. The measurement of Contact Angle is the main method of surface performance detection at present.

LS-SDC-1000 type platform contact Angle measurement instrument is using the principle of optical imaging, image contour analysis way to measure the surface contact Angle, bevochtigbaarheid, grensvlakspanning van de tafel, oppervlakte energie, zoals prestaties, equipment cost-effective, comprehensive functions, high test precision and can meet the large size products, such as TV flat glass and other special products with conventional sample measurement needs.

 

LS-SDC-1000 Large platform optical contact Angle Tester

Toepassing

Contact Angle measuring instrument is widely used in various industries, in mobile phone manufacturing, glas productie, oppervlakte behandeling, materiaal onderzoek, chemistry and chemical industry, halfgeleider productie, coating inkt, elektronisch circuit, textielvezel, medische biologie en andere gebieden, contacthoekmeting is een belangrijk instrument geworden om de oppervlakteprestaties te evalueren.

(Some test functions need special accessories to be purchased)

  1. The wetting behavior of liquid on solid surface such as spreading, penetratie en absorptie, and the static contact Angle is measured by the block drop method;
  2. Forward Angle, achterwaartse hoek, contact Hoekvertraging, rolling Angle and dynamic contact Angle measurement of material on solid surface;
  3. Continuous real-time research and process recording of absorbing materials, and curve analysis of contact Angle change with time;
  4. Measurement of contact Angle of various special materials, zoals poeder, gebogen oppervlak, superhydrophobic/superhydrophilic samples;
  5. Attachment drop method to test the contact Angle of materials immersed in liquid;
  6. Suspension drop method is used to measure the interfacial tension and its polarity and dispersion components of various liquid surfaces.
  7. Calculation of Surface free energy of solid and analysis of polar dispersion component;
  8. Analyze the adhesion energy of liquid on solid surface and evaluate the uniformity and cleanliness of solid surface.

Beginsel

Zoals weergegeven in de bovenstaande afbeelding, het contacthoekmeetinstrument bestaat voornamelijk uit een lichtbron, injectie eenheid, sample platform, acquisition system and analysis software. De apparatuur maakt gebruik van het principe van optische beeldvorming.

The light source adopts intensive LED cold light design, uniform luminous, image cleaning, long life;

The injection unit adopts high-precision injection pump, which is controlled by software quantitative and constant speed, with stable drip and high precision.

Sample table adopts 3d manual fine-tuning platform, flexible operation, accurate positioning, sample table can be customized according to the actual sample size;

The acquisition system adopts black and white imported CCD camera, stable shooting, clear image, real and reliable, the lens adopts telephoto German industrial grade telephoto zoom imported configuration, 0.7-4.5 times magnification adjustable, imaging without distortion;

The analysis software is powerful, met automatische aanpassing met één knop, with the world’s leading fitting method, to meet the precise fitting of various droplet forms;

LS-SDC-1000 Large platform optical contact Angle Tester

Specificaties:

Gastmachine
Boundary dimension1430mm(length)*480mm(Breedte)* 690mm(height)
Gewicht50.5KG
Stroomvoorziening220V / 60HZ
Lichtbronsysteem
LichtbronDense LED adjustable blue tone industrial grade cold light source
Life spanService life of more than twenty-five thousand hours
Injectie-eenheid
Injection syringeSpecial high precision quartz syringe, volume 500μL
Dropping liquidSoftware control automatic liquid feeding, precision up to 0.01μL
Beweging van de injectie-eenheidUp down 60mm; left. Right 100mm
Acquisitie systeem
CcdSONY imported high speed industrial grade chip, 25 kaders /S, 130W pixel
Lens0.7-4.5 times hd industrial-grade continuous variable magnification microscope
Acquisition system adjustmentBefore and after 60 mm, view Angle adjustable (smooth inspect, look down, 360 ° rotating Angle of view, enzovoort)
Sample station installation
CPJ-4025W CPJ-3020W Horizontale digitale profielprojector400mm*500mm
Maximum sample size21inch
Sample stand movementBefore and after manual movement, stroke 200mm

Left and right manual movement, stroke 250mm

Manual up and down movement, stroke 20mm, accuracy 0.1mm

The platform can be rotated 360°

Analyse software
Measuring range of contact Angle0-180​
Contact Angle measurement accuracy±0,1°
Table interfacial tension measurement range0-2000mN/m
Table interfacial tension measurement accuracy0.01 mN/m
Analyzing software functions1. Automatic fitting method of the most advanced contact Angle measurement and analysis software in China (automatische montage met één sleutel,

There is no artificial error), inclusief :(Cirkel methode), (Ellipse/ Ellipse), LY, (Differential Circle/Differential Ellipse);

2. Dynamisch contact Hoekfitting (batch fitting of multiple images) includes:

(Wettability), (Video analysis);

3. (Surface Energy);

4, (Surface tension);

5. (Adhesion work);

Accord with National Standard

1.GB / T 24368-2009(detection of hydrophobic contaminants on glass surface);

2.SY/T5153-2007 (method for determination of wettability of reservoir rocks);

3.ASTM D 724-99 (2003) (Test Method for Surface Wettability of Paper);

4.ASTM D5946-2004 (Measurement of Contact Angle between Plastic Film and water);

5.ISO15989 (Measurement of water contact Angle of plastic film and thin plate corona treated film);

Neem contact met ons op