NIEUWS

What does the dielectric constant tester measure? What are its uses?

The dielectric constant tester is a measuring instrument, the instrument is mainly used for the instrument can be used in scientific research institutions, scholen, such as some scientific research institutes, colleges and universities or measurement and testing departments of the laboratory need to use the dielectric constant tester to test the dielectric constant of insulation materials; Tegelijkertijd, it is also suitable for factories or units, such as some factories to conduct research on the application of inorganic...

What is the glass transition temperature? What instruments are used to measure

Onlangs, many customers will ask what instrument can measure the glass transition temperature, this term may not be understood by many people, but people engaged in the dsc instrument industry are very familiar with the glass transition temperature, and often use dsc (differentiële scanningcalorimeter) to test the glass transition temperature of different materials. Through the test map and data for material analysis, especially scientific research institutes, university laboratories and plastics, pipes and other enterprises, often use dsc thermal analysis...

Principes van geleidbaarheidsanalysator

Een elektrische geleidbaarheidsanalysator is een instrument dat wordt gebruikt om de elektrische geleidbaarheid van een oplossing te meten. Het werkt volgens het principe van de geleidbaarheid van ionen in oplossing. Het basisprincipe: Geleidingsprincipe: Ionen die in een oplossing aanwezig zijn, hebben een elektrische lading en kunnen zich in een elektrisch veld verplaatsen. Wanneer een elektrisch veld wordt aangelegd, ionen worden verplaatst door de elektrische veldkracht. Over een bepaalde afstand, the speed at which an ion moves is proportional to its charge and the strength...

Wijze van gebruik van de PH-meter

The following is the general PH meter use method: 1.Preparation work: Check that the electrodes of the pH meter are clean and intact. Make sure the pH meter electrodes are calibrated or have been recently calibrated. Make sure the pH meter has enough battery power or is connected to a power source. Method of using PH meter 2.Prepare sample: Prepare the sample to be tested and place it in a suitable container. If needed, stir or mix the sample to ensure even distribution. 3.To measure pH value: Turn on the...

Paint adhesion test

Coating adhesion testing is an important quality control measure to ensure the durability, performance and safety of the coating by assessing the adhesion between the coating and the substrate. It helps prevent coating peeling and guarantees product appearance quality while meeting industry standards and certification requirements. Adhesion testing is important to ensure coating quality, improve product reliability, and meet customer expectations. The adhesion of the paint surface can be tested by one of the following methods: Cross Cut Test (Cross Cut Test)...

Common problems with coating rods

The coating measuring rod is a device that can be used to accurately control the quantity (wet film thickness) in experiment or production. It can ensure the smooth film layer and estimate the film thickness by controlling the coating thickness and scraping uniformity. Here are some examples of common problems with coating rods: What are the selection criteria for coating metering rods? Which coating materials are suitable for different types of coating metering rods? How to choose the appropriate coating measuring rod size and...

ASTM D16-2016 Standaardvoorwaarden voor coatings, Gerelateerde coatings, Materialen, en toepassingen

Stap 1: Domein 1.1 This standard includes the technical terms used in standards within the jurisdiction of ASTM Committee D01 (Coatings and Related Coatings, Materialen, en toepassingen), and the definitions applicable to those standards. Opmerking 1: When any definition of this standard is referenced or published in the context of this standard, the following delimiting statement "for paints and related coatings, materials and applications" is editorially inserted after the dash following the term (where there is none). Existing declaration of delimitation). Dit...

ASTM D2240-2015 “Standaard testmethode voor het bepalen van de rubberhardheid met een hardheidstester”

Radius The test method covers twelve types of rubber hardness measuring devices called durometers: EEN, B., C, D, DOEN, E., M., O, OO, OOO, OOO-S- en R-types. De procedure voor het bepalen van de indrukhardheid beschrijft ook stoffen die zijn geclassificeerd als thermoplastische elastomeren, gevulkaniseerd (thermoharder) rubbers, elastomeer materialen, poreuze materialen, gelachtige materialen, en bepaalde kunststoffen. Deze testmethode is niet gelijkwaardig aan andere methoden voor de hardheid van de inkeping en instrumenttypes, in het bijzonder die beschreven in testmethode D1415. This test method is not applicable to the...