ASTM D 6304 Karl Fischer Trace Moisture Analyzer ASTM D1533 Coulometric Karl Fischer Trace Titrator

This trace moisture analyzer is based on the Karl Fischer coulometric titration principle and conforms to the Karl Fischer method (Method III) in GB/T 2288-2008, “Determination of Moisture in Coking Products.” It supports multiple calculation formulas and conforms to standards GBT11133, ASTM D 6304, and ASTM D1533.

kategori:

Penerangan

Karl Fischer Trace Moisture Analyzer

Penerangan:

This trace moisture analyzer is based on the Karl Fischer coulometric titration principle and conforms to the Karl Fischer method (Method III) in GB/T 2288-2008, “Determination of Moisture in Coking Products.” It supports multiple calculation formulas and conforms to standards GBT11133, ASTM D 6304, and ASTM D1533.

It employs microcomputer automatic control, with a 32-bit embedded microprocessor as the main control core and an embedded mini operating system. The instrument features constant current detection and dual-circuit equilibrium titration functions. The electrolytic cell adopts a new waterproof sealing design. Compared with similar advanced products at home and abroad, it has advantages such as high sensitivity, fast electrolysis speed, masa keseimbangan yang singkat, penolakan kosong yang tepat, dan keputusan analisis yang tepat dan boleh dipercayai. Ia adalah instrumen analisis berkualiti tinggi untuk petroleum, kimia, kuasa, perlindungan alam sekitar, farmaseutikal, dan sektor penyelidikan saintifik.

Mematuhi piawaian berikut:

GB/T7600 “Penentuan Kandungan Lembapan dalam Minyak Transformer Semasa Operasi (Kaedah Coulometrik)”

GB6283 “Penentuan Kandungan Lembapan dalam Produk Kimia – Kaedah Karl Fischer (Kaedah Umum)”

SH/T0246 “Penentuan Kandungan Air dalam Produk Petroleum Ringan (Pekali Kelembapan)”

SH/T0255 “Penentuan Kandungan Lembapan dalam Aditif dan Minyak Pelincir yang Mengandungi Aditif (Pekali Kelembapan)”

GB/T11133 “Penentuan Kandungan Air dalam Produk Petroleum Cecair (Kaedah Kal Fischer)”

GB/T7380 “Penentuan Kandungan Air dalam Surfaktan (Kaedah Kal Fischer)”

GB10670 “Penentuan Lembapan Surih dalam Fluorometana Industri – Kaedah Karl Fischer”

GB/T606 “General Method for Determination of Moisture in Chemical Reagents – Kaedah Karl Fischer”

GB/T8350 “Denatured Fuel Ethanol”

GB/T8351 Ethanol Gasoline for Vehicles

GB/T3776.1 Determination of Moisture Content in Pesticide Emulsifiers

GB/T6023 Determination of Trace Moisture in Industrial Butadiene – Karl Fischer Coulometric Method

GB/T3727 Determination of Trace Moisture in Industrial Ethylene and Propylene

GB/T7376 Determination of Trace Moisture in Industrial Fluorinated Alkanes

GB/T18619.1 Determination of Water Content in Natural Gas – Karl Fischer Coulometric Method

GB/T512 Determination of Moisture Content in Lubricating Greases

GB/T1600 Determination of Moisture Content in Pesticides

GB/T11146 Determination of Water Content in Crude Oil (Kal Fischer Coulometric Method)

GB/T12717 Test Method for Industrial Acetates

GB/T5074 Determination of Moisture Content in Coking Products

GB/T18826 Gred Perindustrian 1,1,2-Tetrafluoroethane (HFC-134a)

Karl Fischer Trace Moisture Analyzer

Parameter Teknikal:

Kaedah koulometrik Karl Fischer adalah kaedah yang boleh dipercayai untuk menentukan kelembapan surih dalam pelbagai bahan, mematuhi GB/T11133. Penganalisis kelembapan surih ini berjaya menggunakan kaedah ini dan menggunakan kawalan mikrokomputer. Ia mempunyai kelajuan analisis yang pantas, ketepatan yang tinggi, paparan LCD Cina, percetakan automatik, reka bentuk dwi-CPU, penolakan arus kosong automatik, diagnosis diri kesalahan instrumen, dan fungsi pemilihan menu untuk operasi dan penggunaan yang lebih baik. Ia adalah mudah, instrumen analisis automatik sepenuhnya, sesuai untuk analisis kelembapan minyak.

Paparan Paparan skrin sentuh berwarna
Kaedah Pentitratan Pentitratan elektrostatik dikawal mikrokomputer
Keluaran Pengiraan automatik, output ug, PPM, dan %
Julat pengukuran 0.00001% kepada 100% sebagai peratusan, 0.1ppm kepada satu juta ppm dalam PPM (1ppm = 0.0001%)
Resolusi 0.1dan
Kawalan Elektrolisis Kawalan pengesanan arus elektrolisis automatik (maksimum 400mA)
Kelajuan Pentitratan 2.5mg/min (maksimum)
Sensitiviti 0.1ug-100ug tidak melebihi 2%; di atas 1mg ditukar kepada 0.3% (tidak termasuk ralat suntikan)
Pencetak 36-pencetak haba watak, 44mm lebar kertas
Bekalan Kuasa AC 220V±10% 50Hz±10%
Penggunaan Kuasa 60VA
Suhu persekitaran operasi 5-40℃
Suhu persekitaran operasi ≤90%