PYGCMS Double injector RoHS2.0 testing instrument Double column pyrobenzene detector
Aplikasi

Makanan, elektronik, automotif, elektrik, comprehensive

PYGCMS Double injector RoHS2.0 testing instrument Double column pyrobenzene detector
PYGCMS pyrobenzene detector product features:

1, advanced ceramic heating mode, ceramic body equipped with high precision temperature sensor, precise temperature control, solution straw heating fast and stable, low voltage work, safe and reliable.

2, with the program temperature function, you can set different temperature intervals and gradients;

3, PC software control system, larger expansion performance, operasi yang lebih mudah;

4, abandon the traditional mechanical valve, the use of CNC solenoid valve, gas path control more accurate;

5. Cooperate with EPC electronic pressure controller to better control gas flow rate;

6, equipped with electronic type gas pressure regulator valve and needle type pressure valve, to achieve full computer precise control; Independent intellectual property rights of the valve switching system, no dead volume, stable and efficient, no sample residue.

7, according to the needs of users, different diameters of the sample in the straw heating treatment, the highest temperature can be controlled at 500ºC. Peranti desorpsi dipasang terus pada salur masuk sampel kromatografi gas untuk memastikan penyahsorpsian cepat sampel ke dalam kromatografi.

8, boleh terus ke tiub pensampelan atmosfera standard atau mana-mana bahan pepejal yang mengandungi desorpsi bahan organik, desorpsi, analisis pensampelan.

PYGCMS Double injector RoHS2.0 testing instrument Double column pyrobenzene detector
Parameter description of PYGCMS pyrobenzene detector:

cracking device (Φ6 cracking pipe) temperature range room temperature ~ 450ºC, with an increment of 1ºC set.
cracking device (Φ6 cracking tube) heating rate >500ºC/ min.
cracking device cracking time range 0.01 ~ 99.99min, with an increment of 0.01min set
The purging time range of the cracking device 0.01 ~ 99.99min, with an increment of 0.01min
Purge flow range of the cracker 10ml ~ 200ml.
the separation flow range of the cracking device 10ml ~ 200ml.
cracking device heating control voltage 16VDC
aging cleaning device temperature range room temperature ~ 450ºC, with an increment of 1ºC set (pilihan)
Time range of aging cleaning device 1 ~ 1200min, with an increment of 1min

PYGCMS Double injector RoHS2.0 testing instrument Double column pyrobenzene detector

Procurement cost dalam 350,000 Take samples every day 30-40 of them
Injection method Direct solid or liquid Cost of use/year 8000 yuan/year
Whether chemical pretreatment is required No chemical pretreatment is required Lower detection limit 50ppm
Sample time 20 minutes/sample Degree of operation difficulty Simple and easy to operate, ordinary production line staff can operate
Sample pretreatment or not Don’t need Whether a professional laboratory is needed Tidak, normal office environment is fine

Don’t need

Sama ada penilaian alam sekitar diperlukan
Don’t need
Sama ada air buangan dan gas buangan dihasilkan tidak ada

instrumen RoHS2.0