BERITA

ASTM D2244-0 “Test Method for Calculating Color Difference by Means of Instrumental Determination of Color Coordinates”

ASTM D2244 is a standard test method used to calculate the color difference of the color coordinates measured by an instrument. The color of the sample is measured and the result can be expressed on the L, a, b or x, y, z scale. This test method is often used in conjunction with other accelerated aging test methods associated with UV testing, such as ASTM G155, ASTM G154, ASTM F1515 and many other material test methods. Color measurement usually requires other...

Amalan Standard ASTM D2565-0 untuk Peranti Pendedahan Arka Xenon untuk Plastik Luaran

ASTM D2565 ialah amalan standard untuk pendedahan arka xenon plastik untuk aplikasi luar. Amalan ini meliputi prosedur dan syarat ujian khusus berdasarkan amalan ujian berkaitan ASTM G151 dan ASTM G155. ASTM D2565 juga meliputi penyediaan sampel ujian, keadaan ujian yang sesuai untuk plastik, dan penilaian keputusan ujian. Use and factors to consider When exposed to outdoor conditions such as ultraviolet radiation, panas, dan air, mekanikal, elektrik, dan sifat optik polimer berubah dengan ketara. The ASTM D2565...

The plate method thermal conductivity meter is a test tool for developing and researching materials with low thermal conductivity

Meter kekonduksian haba kaedah plat mempunyai banyak kelebihan seperti sampel ujian kawasan besar, pelbagai jenis (bahan tunggal atau bahan komposit) bahan ujian, kawalan suhu ketepatan tinggi, prestasi yang boleh dipercayai dan stabil, tahap automasi kawalan yang tinggi, operasi mudah dan sebagainya. The thermal conductivity test principle of the plate method is an absolute measurement method and does not require any calibration standards. The instrument is produced according to relevant standards, the test is accurate, the operation is simple, is...

How to measure the glass transition temperature of pet? What kind of testing equipment

In order to study the quality and characteristics of materials, many industries will use differential scanning calorimeter to test the glass transition temperature of materials, especially the glass transition temperature of PET(poliester), which is also a more common measurement. What is the glass transition temperature? The glass transition temperature (Tg) refers to the temperature corresponding to the transition from a glassy state to a high elastic state. The glass transition is an inherent property of amorphous polymer materials, which is a...

How to choose thermogravimetric analyzer?

Thermogravimetric analyzer is a thermogravimetric method to detect the relationship between the development and change of the material environment temperature and quality management. By heating the material, the material will gradually volatilize and decompose, and the weight change with the increase of temperature will be measured. This can be used to determine certain physical properties of substances, such as decomposition temperature, melting point, dan seterusnya. Measuring the relationship between sample mass and temperature can detect changes in sample mass...

How to choose dsc differential scanning calorimeter? Can you measure the glass transition temperature

What is a dsc differential scanning calorimeter? It is a thermal analysis instrument, which is mainly used to test the glass transition temperature, tempoh induksi pengoksidaan, kehabluran, melting heat and crystallization heat, kesucian, reaction kinetics, specific heat, phase transition temperature, dan lain-lain., and is widely used in plastics, getah, serat, salutan, pelekat, perubatan dan industri lain. How to choose dsc differential scanning calorimeter? It is also a problem that many buyers are more concerned about. Pada masa ini, there are many manufacturers and...

Penguji abu terutamanya terdiri daripada tiga bahagian

The ash tester is improved on the basis of ordinary high temperature resistance furnace (Muffle furnace), using energy-saving materials, which is one-third of the energy consumption of the original resistance furnace, and the heating rate is three times that of the original resistance furnace. The control system adopts LTDE technology, automatic intelligent control, output power percentage, slope correction, automatic constant temperature, automatic shutdown, and PID function to ensure the correct temperature at a certain point. It can be used to...

How to use a fast thermal conductivity meter?

The fast thermal conductivity meter is a new type of thermal conductivity measuring instrument, which is a kind of measuring the thermal conductivity of a sample (padu, liquid or powder) as a function of temperature. The transient plane heat source method can measure the thermal conductivity quickly and accurately in the study of materials, which provides great convenience for the quality control of enterprises, material production and laboratory research. Widely used in various industrial materials, rubber tires, bahan binaan, refractory...