BERITA

Operating rules for laboratory grinding and dispersing machines

The operating procedures of the laboratory grinding and dispersing machine can be carried out according to the following steps: Kerja penyediaan: Ensure that the power connection of the laboratory grinding and dispersing machine is normal, and check whether all safety devices of the equipment are in good condition. Check the type and quality of grinding media (cth. grinding beads) to ensure that they meet the test requirements. Prepare samples to be ground and dispersed, and prepare the appropriate solvent or medium as required. Operating rules...

Hydraulic disperser can not lift how to do?

If the hydraulic disperser does not rise or fall, it may be due to the following reasons: Hydraulic system failure: Check the working state of the hydraulic system, including whether the hydraulic oil is enough, whether the hydraulic pump works normally, whether the hydraulic pipeline is blocked, dan lain-lain. If a fault is found, the relevant parts of the hydraulic system need to be repaired or replaced. Hydraulic valve failure: The lifting operation of the hydraulic disperser is usually controlled by the hydraulic...

Lekatan Basah Cat Lateks pada Substrat Enamel Alkyd Gloss Tinggi

Maksud dan kegunaan 5.1 Cat lateks mungkin tertakluk kepada kelembapan yang tinggi, pemeluwapan atau pemendakan selepas menyalut permukaan dalam atau luar. Ini kadangkala boleh mengakibatkan kehilangan lekatan pada substrat di mana ia digunakan. Kaedahnya ialah pengukuran kuantitatif lekatan antara cat lateks dan substrat berkilat dalam kes ini. julat 1.1 Kaedah ujian ini meliputi prosedur untuk mengukur lekatan cat lateks pada substrat enamel alkyd berkilat dengan menggosoknya selepas terdedah kepada keadaan basah. 1.2...

ASTM D5007-99-2017 “Standard Test Method for Changes in Wet-Dry Covering Power”

Maksud dan kegunaan 5.1 Many architectural paints, especially white and light paints, change significantly in film opacity as they dry. Increased coverage is sometimes associated with porosity and poor film integrity in conventional formulations. The reduction can lead to disappointing paint jobs. Oleh itu, the change in covering power from wet to dry is a property of great practical significance. 5.2 This test method can be used for paint specifications and as a brief procedure for assessment and quality control. ASTM D5007-99-2017 "Standard Test...

Salutan Sudut Salutan Serbuk ASTM D 2967-2017

Maksud dan kegunaan 4.1 Kaedah ujian ini mengukur sejauh mana bahan serbuk salutan yang berbeza meliputi sudut tajam. Liputan sudut dipengaruhi oleh ketebalan permukaan, thixotropy, mencairkan kelikatan, ketegangan permukaan, kadar pengawetan, dan suhu aplikasi dan pengawetan. julat 1.1 Kaedah ujian terdiri daripada menentukan nisbah ketebalan sudut (lihat 3.1.3) kepada ketebalan permukaan (lihat 3.1.4) of the powder coating applied to a particular surface thickness by dipping a preheated square rod into an aerated powder and curing the coating using...

ASTM D 4217-2017 “Gelation Time of Thermosetting Powder Coatings”

Maksud dan kegunaan 4.1 This test method can be used to select coating powders that gel at specified temperatures for the required time. This method is not useful for determination of curing time. julat 1.1 This test method determines the length of time required for a thermosetting coating powder to gel on a polished metal surface at a specified temperature (cth. 204°C (400°F)). Gel time determination is a very simple method to characterize and quality control coating powders. Namun begitu, the gel time determined...

Kad Warna RAL K5 dan K7

Kad warna ral adalah sistem rujukan warna standard yang biasa digunakan untuk menggambarkan dan membandingkan warna pelbagai objek. Kad Warna RAL tersedia dalam beberapa siri, termasuk siri K5 dan K7, dan perbezaan di antara mereka adalah seperti berikut: Kad warna k5: Kad Warna K5 adalah satu siri kad warna ral, juga dikenali sebagai siri klasik K5. Ia mengandungi 213 warna biasa dan merangkumi gamut dan warna yang luas, termasuk kelabu, Biru, Hijau, merah, kuning, orange...

Kaedah ujian standard untuk warna cecair yang jelas (Skala Platinum-Cobalt)

Skala Platinum-Cobalt adalah kaedah ujian standard biasa untuk warna cecair telus, yang digunakan untuk penilaian kualitatif dan kuantitatif warna cecair. Berikut adalah prinsip asas dan prosedur operasi skala platinum-kobalt: Prinsip: Skala Platinum-Cobalt adalah satu set penyelesaian standard warna cecair yang terdiri daripada platinum dan kobalt. Skala Platinum-Cobalt diselaraskan oleh kecerunan tumpuan untuk mendapatkan tahap warna yang berbeza, dari tidak berwarna secara beransur -ansur ke kedalaman warna yang berbeza. The color level of the liquid can be...