ASTM D 6304 Karl Fischer Trace Moisture Analyzer ASTM D1533 Coulometric Karl Fischer Trace Titrator
This trace moisture analyzer is based on the Karl Fischer coulometric titration principle and conforms to the Karl Fischer method (Method III) in GB/T 2288-2008, “Determination of Moisture in Coking Products.” It supports multiple calculation formulas and conforms to standards GBT11133, ASTM D 6304, and ASTM D1533.
- Descrizione
- Inchiesta
Descrizione
Karl Fischer Trace Moisture Analyzer
Descrizione:
This trace moisture analyzer is based on the Karl Fischer coulometric titration principle and conforms to the Karl Fischer method (Method III) in GB/T 2288-2008, “Determination of Moisture in Coking Products.” It supports multiple calculation formulas and conforms to standards GBT11133, ASTM D 6304, and ASTM D1533.
It employs microcomputer automatic control, with a 32-bit embedded microprocessor as the main control core and an embedded mini operating system. The instrument features constant current detection and dual-circuit equilibrium titration functions. The electrolytic cell adopts a new waterproof sealing design. Compared with similar advanced products at home and abroad, it has advantages such as high sensitivity, fast electrolysis speed, short equilibrium time, accurate blank subtraction, and accurate and reliable analytical results. It is a high-quality analytical instrument for petroleum, chimico, ~199,9 mm/s (valore effettivo), protezione ambientale, farmaceutico, and scientific research sectors.
Complies with the following standards:
GB/T7600 “Determination of Moisture Content in Transformer Oil During Operation (Coulometric Method)”
GB6283 “Determination of Moisture Content in Chemical Products – Karl Fischer Method (General Method)”
SH/T0246 “Determination of Water Content in Light Petroleum Products (Coefficient of Moisture)”
SH/T0255 “Determination of Moisture Content in Additives and Additive-Containing Lubricating Oils (Coefficient of Moisture)”
GB/T11133 “Determination of Water Content in Liquid Petroleum Products (Kal Fischer Method)”
GB/T7380 “Determination of Water Content in Surfactants (Kal Fischer Method)”
GB10670 “Determination of Trace Moisture in Industrial Fluoromethanes – Karl Fischer Method”
GB/T606 “General Method for Determination of Moisture in Chemical Reagents – Karl Fischer Method”
GB/T8350 “Denatured Fuel Ethanol”
GB/T8351 Ethanol Gasoline for Vehicles
GB/T3776.1 Determination of Moisture Content in Pesticide Emulsifiers
GB/T6023 Determination of Trace Moisture in Industrial Butadiene – Karl Fischer Coulometric Method
GB/T3727 Determination of Trace Moisture in Industrial Ethylene and Propylene
GB/T7376 Determination of Trace Moisture in Industrial Fluorinated Alkanes
GB/T18619.1 Determination of Water Content in Natural Gas – Karl Fischer Coulometric Method
GB/T512 Determination of Moisture Content in Lubricating Greases
GB/T1600 Determination of Moisture Content in Pesticides
GB/T11146 Determination of Water Content in Crude Oil (Kal Fischer Coulometric Method)
GB/T12717 Test Method for Industrial Acetates
GB/T5074 Determination of Moisture Content in Coking Products
GB/T18826 Industrial Grade 1,1,2-Tetrafluoroethane (HFC-134a)
Karl Fischer Trace Moisture Analyzer
Parametri tecnici:
The Karl Fischer coulometric method is a reliable method for determining trace moisture in various substances, conforming to GB/T11133. This trace moisture analyzer successfully applies this method and employs microcomputer control. It features fast analysis speed, alta precisione, a Chinese LCD display, automatic printing, a dual-CPU design, automatic blank current subtraction, instrument fault self-diagnosis, and menu selection functions for better operation and use. It is a simple, fully automatic analytical instrument, ideal for oil moisture analysis.
| Schermo | Color touchscreen display |
| Titration Method | Microcomputer-controlled electrostatic titration |
| Output | Automatic calculation, outputs ug, PPM, e % |
| Campo di misura | 0.00001% a 100% as a percentage, 0.1ppm to one million ppm in PPM (1ppm = 0.0001%) |
| Risoluzione | 0.1ug |
| Electrolysis Control | Automatic electrolysis current tracking control (maximum 400mA) |
| Titration Speed | 2.5mg/min (massimo) |
| Sensibilità | 0.1ug-100ug not exceeding 2%; above 1mg converted to 0.3% (excluding injection error) |
| Stampante | 36-character thermal printer, 44mm paper width |
| I coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del paziente | AC 220V±10% 50Hz±10% |
| Consumo energetico | 60Va |
| Operating ambient temperature | 5-40℃ |
| Operating ambient temperature | ≤90% |