Macchina per il test dell'integrità del filtro LS-470

Integrity Tester are designed for testing integrity of filters and filter systems . The State Pharmacopoeia and GMP specification requirements. The LR-470 Integrity Tester is compact, handy to use, and fully automated integrity test instrument, which performs bubble point, diffusion flow, enhanced bubble point, and water-based test for hydrophobic filters. The first domestic launch of integrity test for water-based test for hydrophobic filters to meet different customer needs.

Descrizione

LS-470 Filter Integrity Tester machine

introduzione:
Integrity Tester are designed for testing integrity of filters and filter systems . The State Pharmacopoeia and GMP specification requirements. The LR-470 Integrity Tester is compact, handy to use, and fully automated integrity test instrument, which performs bubble point, diffusion flow, enhanced bubble point, and water-based test for hydrophobic filters. The first domestic launch of integrity test for water-based test for hydrophobic filters to meet different customer needs.

I coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del paziente:

I coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del paziente 100 – 260 V.AC, 50HZ, 120W ;
Operation pressure 100-8000mbar (115psi) ;
~199,9 mm/s (valore effettivo) mbar
Condizione operativa Temperatura ambiente:+5℃ ~ +40 ℃;Umidità relativa:10-80%
Dimensione (mm) 400(Profondità)*240(Larghezza)*270(Altezza1)*220(Altezza2)
Funzione di prova Manual Bubble point Test;Basic Bubble Point Test;Extensive Bubble Point Test;Diffusion Flow Test;Water Immersion Test;
Precisione del test Upstream Volume:± 4%;Punto di bolla:≤± 50mbar ;Diffusion Flow Test:≤± 4% ;Water Immersion Test:≤± 0.05ml
Ambito di prova Punto di bolla :590-6900mbar Diffusion Flow Speed:1-180ml/min WI:0.01-30ml/min
Gamma applicata Symmetric and asymmetric membrane test, filtro ad ago, sacchetto filtro, filtro piatto, filter cartridge (3 nucleo interiore 20 U30,U35,DLF)
Funzione di stampa Stampante incorporata;
Documenti storici 500 insiemi;
Display Screen 5.7″TFT,Single color;
Serial Connection RS232;
Lingua cinese/inglese;
Modalità di lavoro In linea/non in linea;
Ambiente applicabile Sopra il livello D;
Peso 7.5KG;

Caratteristiche principali:

1.The scientific electronic signature and classification to distinguish the responsibility easily, and to prevent false operation.
2.Display of test data and curves in real time, monitoring the whole process of testing.
3.Provides automatic printing set function, the user can operate more simple and convenient.
4.Water Based test (WH) for Hydrophobic Filter: using purified water as test liquid instead of IPA and Ethanol, thus it can avoid trace quantity of ethanol or IPA contamination when testing filters.
5.The instrument can store 500 history record and curve.

 

Applied range:

Disc Membrane:Φ25mm-Φ300mm;
Standard Cartridge:2.5"- 40"
Capsule & Mini Catridge
Air filter test :2.5"- 40