LS-210 Three Box Thermal Shock Chamber

Categorie:

  • Descrizione
  • Inchiesta

LS-210 Three Box Thermal Shock Chamber

Uso

Programable thermal shock chamber price is used to test the change of material under extremely high temperature and extremely low temperature environment that continue alternation in the shortest time,Testing the chemical changes or physical damage of material caused by the thermal expansion and contraction. Testing box divided two parts, one is hightemperature region, another is low-temperatureregion, the testing sample placed on the moving basket, using unique heat storage and cool storage,the cylinder taking basket moves up and down in the hot and cold region to complete the hot and cold temperature impact testing.

 

LS-210 Three Box Thermal Shock Chamber

Specifica

ModelloUN

(A~D)

B

(A~D)

C

(A~D)

~199,9 mm/s (valore effettivo)

(A~D)

E

(A~D)

F

(A~D)

Inner size: WHD(centimetro)40*35*3050*30*4050*40*4050*50*4060*40*5060*50*50
External size: WHD(centimetro)150*180*150160*175*160160*185*160160*185*170170*185*170170*195*170
Intervallo di temperatura(Test Chamber)high temperature:+60℃~+200℃;low temperature -10℃~-65℃(UN:-45℃;B:-55℃;C:-65℃)
Heating TimeRT~200℃ About 30min
Cooling TimeRT~-70℃ About 85min
Temperature Conversion TimeLess than 10S
Temperature Recovery TimeLess than 5min
Temperature Deviation±2,0 ℃
Temperature Fluctuation±0,5℃
con alto grado di automazioneExternal material: SUS#304 Stainless steel plate

Internal material:SUS#304Stainless steel plate

Output ModeWater-cooled or air-cooled,Taikang compressor in France
ControlloreTEMI South Korea
Cooling SystemWater-cooled or air-cooled,Taikang compressor in France
Protection devicesFuse switch, compressor overload switch, refrigerant high and low pressure

protection switch,super humidity over-temperature protection switch,

fuse, failure warning system

patrsWatching window;50mm testing hole; partition plat
EnergiaAC380V 50/60Hz Three-phase four-wire ac power
il peso (riflettività di scissione della luce)7507908308809501050

 

LS-210 Three Box Thermal Shock Chamber

1. Profile.
1.1 ArticoloThermal shock test chamber (three zone)
1.2 ModelloLR-B010
1.3 Sample restrictions

 

 

The equipment is prohibited to do the test and storing as below:

Flammable, explosive, volastile substances;

Corrosive substances;

Biological samples;

Source of strong electromagnetic radiation.

1.4 Condizione di testEnvrionmental temperature: +25℃; umidità: ≤85%, with no samples inside the chamber
1.5 Metodo di provaGB / T 5170.2-1996 temperature test chamber and so on
1.6 Meet the test standardMeet GB2423, IEC68-2-14, JIS C 0025, MIL-STD-883E,

IPC 2.6.7, BELLCORE and other standards

2. parametri tecnici.
Inner size (WxHxD)mm400×350×300mm
Inner volume42I coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del paziente
External size (WxHxD)mm1550x1650x 1470mm
Preheating temperature+60℃~+200℃ (heat up +25℃~+200℃∕ 20min)
Precooling temperature-10℃ ~-45℃ (cooling +25℃~-45 ℃∕65min)
High temp. shock range+60℃~+150℃
Low temp. shock range-10℃~-40℃
Fluttuazione della temperatura±0,5℃
Temperature deviation±2,0 ℃
Shock recovery time≤5min (control point)

Contattaci