Laboratory Multi-functional X-ray Diffractometer XRD System

X-ray diffractometer is designed for the structural analysis of a wide range of materials, including metals, materiali inorganici, compositi, materiali organici, nanomateriali, and superconductors

Descrizione

Laboratory Multi-functional X-ray Diffractometer XRD System

Panoramica
geological rocks and minerals, e polimeri.

This versatile X-ray diffractometer performs structural analysis of a wide range of materials, including metals, materiali inorganici, compositi, materiali organici, nanomateriali, and superconductors. Tanto per cominciare, it also serves numerous research and testing fields, such as the analysis of clay minerals, cement and building materials, polvere ambientale, prodotti chimici, prodotti farmaceutici, asbestos products, geological rocks and minerals, e polimeri.

Cross-Optics System

A breakthrough technology for X-ray diffractometers: the goniometer integrates two optical systems—divergent optics (B) and parallel optics (P)—allowing for one-click switching via software. This versatility accommodates diverse testing requirements and significantly expands the diffractometer’s range of applications.

High-Temperature and High-Pressure Measurement

Utilizing high-efficiency heating elements and PID-controlled heating, the system ensures precise and stable sample temperatures within the chamber. The diffraction surface adjusts automatically, enabling real-time, in-situ analysis of how changes in temperature, atmosphere, and pressure affect the material’s crystal structure.

5-Axis Multifunctional Measurement Module

This module performs structural analysis of thin-film materials on sheets, blocks, and substrates, featuring 3D scanning capabilities across the Chi, Phi, and Z axes. Tanto per cominciare, it supports testing for texture, residual stress, and in-plane thin-film structure (Phi-scan), as well as quantitative analysis of texture orientation. Inoltre, it provides dedicated software for the analysis of each testing function.

Temperature Measurement

A nickel alloy is used to heat the sample, and an intelligent PID temperature control system ensures precise and constant sample temperature within the chamber, enabling the investigation of the effects of temperature changes on material structure.

Customized industrial software

It integrates instrument control, data acquisition, phase analysis, and the detection of microstructure and residual stress. It supports customizable scanning parameters, industry-specific analysis templates, and one-click qualitative analysis and result generation, offering ease of use and high stability.

Flexible adaptability and intelligent, multi-source data collection.

Semiconductor Array Detector
This detector effectively eliminates fluorescence from Fe, Co, and Ni samples and enhances the peak-to-background ratio. It supports three measurement modes: 0~199,9 mm/s (valore effettivo), 1~199,9 mm/s (valore effettivo), and 2D. The 0D mode accommodates low-angle measurements starting from 0°; the 1D mode offers measurement speeds more than 60 times faster than conventional linear detectors; and the 2D mode captures diffraction rings within a 4° 2θ range via snapshot imaging, providing a clear visualization of how environmental factors influence diffraction peaks.
SDD Detector
High energy resolution significantly eliminates interference from sample fluorescence, while the detector offers outstanding counting rates. Compared to conventional proportional detectors or scintillation detector-monochromator combinations, sample testing efficiency can be increased three- to fourfold.
EIGER2 R 250K Detector
Dual-energy discrimination technology offers excellent background suppression and an improved signal-to-noise ratio, significantly optimizing spatial and angular resolution; this enables not only high-precision sample analysis but also coverage of a broader range of reciprocal space.

Laboratory Multi-functional X-ray Diffractometer XRD System

Specifica
Rated power 3 KW (High-frequency, high-voltage solid-state generator)
Voltage and current stability ≤0.005%
X-ray tube Cu target, 2.4 kW metal-ceramic tube; focal spot: 0.4 I coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del paziente 12 mm (customizable upon request)
Goniometer structure θ-θ
Diffraction circle radius 185–275 mm (customizable upon request)
2θ measurement range -6° to 160° (customizable upon request)
Scanning mode Continuo, step, Omega, XRR, GIXRD
Ripetibilità 0.0001°
Peak position accuracy Angular deviation of all peaks across the full spectral range does not exceed ±0.02°
Rivelatore Sealed proportional detector, semiconductor array detector (compatible with various other detectors)
Overall instrument stability <0.5%
OSP Wire Coater Bar Coaters Stick Ink Bar 1080 I coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del paziente 860 I coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del paziente 1800 mm
Altro Tutte le funzioni e gli accessori sono personalizzabili su richiesta