JX14B Digital Large Scale Toolmaker’s Microscope

Caratteristiche

1 ,The photoelectrical technique is adopted, with a precision grating rule as a measurer for X- and Y-axle as a measurer, with readings direct-viewing and testing convenient.

2 ,The photoelectrical technique is adopted, with a precision grating rule as a measurer for X- andY-axle and a numbering device as a measurer for the rotary working table, to realize the length andangle full-display; with readings direct-viewing and testing convenient.

3 ,With multiple eyepieces and objectives,the main microscope has a large scope ofview field with clear image formation.

4 ,The main microscope can oscillate left and right, suitable for the measurement for spiral parts.

5 ,LED-luminotron lighting is adopted for transmission and indirect lighting, with low heating power and long life.

6 ,High-speed and micro-motion devices are adopted; which can be switched over quickly.

7 ,The tailstock rack is installed to measure the axel-type parts.

8 ,Multiple accessories are provided, with extensive uses.

JX14B Digital Large Scale Toolmaker’s Microscope

Parametri tecnici

1 ,Tavolo da lavoro

1.1Measuring stroke of the coordinate

X-coordinate: 150mm Y-coordinate: 75mm

1.2Measuring resolution ratio of X- and Y-coordinate: 0.001mm

1.3Accuracy of the instrument: (2+L/50)micron, of which, L = measured length ( unità: mm)

1.4Diameter of the circular worktable:

Φ190mm(bicchiere) Φ280mm(metallo)

1.5Angular calibrated range of the circular worktable: 0°~ 360°

1.6Measured-angle resolution ratio of the circular worktable: 3 ′

2 ,Microscope upright column

2.1Sloping scope: ±12°

2.2Calibrated value of the slope angle: 30′

3 ,Goniometric eyepiece

3.1Angular calibrated range: 0°~ 360°

3.2Angular calibrated value: 1 ′

4 ,Template eyepiece

4.1Calibrated range of the template eyepiece: ±7°

4.2Angular calibrated value of the template eyepiece: 10 ′

5 ,Optical detector

5.1Minimum detective hole diameter of the optical detector: Φ5mm

5.2Maximum detective depth of the optical detector: 15mm

5.3Measuring power: 0.1I coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del paziente

6 ,Tailstock Frame

6.1Maximum clamping diameter: Φ70mm

6.2Maximum clamping length: 190mm

7 ,Objective

Objective

ingrandimento

Gross

magnifying

~199,9 mm/s (valore effettivo)

Object working

distanza

(mm)

Object visual

field

(mm)

1×

10×

79

Φ20

3×

30×

69

Φ6.7

5×

50×

49

F4

8 ,Maximum bearing workpiece weight by the instrument: 20riflettività di scissione della luce

9 ,Overall sizes ofthe instrument mainframe (mm): 720×460×600

10 ,Mainframe weight: 100 riflettività di scissione della luce

11 ,V-Type Support

Permissible maximumdiameter of a workpiece: 130mm