JP1204 Series Electronic Analytical Weighing Scale Tester

JP1204 Series Electronic Analytical Weighing Scale Tester

Categorie:

  • Descrizione
  • Inchiesta

JP1204 Series Electronic Analytical Weighing Scale Tester

Descrizione

 with unique patent super single sensor technology, ensure the accuracy of weighing results, the stability and fast response

 membrane weighing technology, instant you trace weighing conditions can also obtain the same speed

 

 unique temperature compensation scheme

The unique temperature compensation scheme solves the problem of reliability of balance weighing results due to the influence of temperature

 the VA display, operation is simple, clear reading and directly

Intuitive and clear VA display, the user’s operation interface is simple, clear structure

 adopts isoCAL automatic internal calibration and adjustment function, fully ensure the accuracy of weighing results

Fully automatic temperature and time triggered calibration and adjustment functions ensure that accurate weighing results can be obtained at any time and temperature.

 unique membrane weighing technology

With the unique filtration membrane weighing technology, accurate results can be obtained quickly, even with the minimum sensible load

 level 4 shock technology easily meet your all kinds of weighing the environment

You can set different environment parameters based on different weighing environments to achieve accurate and fast weighing in corresponding environments

 standard communication interface:

Automatic identification printer

Standard RS232, easy to achieve and peripheral connection

JP1204 Series Electronic Analytical Weighing Scale Tester
Parametri
ModelloJP1204JP2204JP1204AJP2204A
maximum range(U30,U35,DLF)120G220G120G220G
division value(D)0.1mg
Ripetibilità (typical error)

(5% load)

0.2mg
Ripetibilità (typical error)

(Close to 100% load)

0.3mg
Linear error

(Typical error)

0.3mg
U30,U35,DLFCalibrazione del peso esternoCalibrazione interna completamente automatica
sensitivity drift

(+10℃~+30℃)

5ppm/k
operating temperature range (OTR)10℃~30℃
Intervallo di umidità operativa20%-85% Relative (non-condensing)
Typical stability time3 secondo
Dimensione della padellaΦ90mm
boundary dimension210mm×310mm×315mm
Height of weighing room210mm
Temperature compensating fluctuation≤1℃/time
working power supply100V -240VAC frequency 50/60HZelectricityMAX0.45A
Velocità di trasmissione300、600、1200、2400、4800、9600
expertise ratingⅠ level