3Spettrofotometro a reticolo da banco NH YS6010 ISO7724/1, ASTM E1164

3Spettrofotometro a reticolo da banco NH YS6010 ISO7724/1, ASTM E1164

Categorie:

  • Descrizione
  • Inchiesta

Introduction-3NH YS6010 benchtop grating spectrophotometer

YS6010 is a benchtop grating spectrophotometer which is developed by 3nh independently with independent intellectual property. YS6010 has many features, like 7 inches TFT capacitive touch screen display, full illuminants, reflective d/8 and transmissive d/0 geometry(including or excluding UV). With very stable and precise color measurement, large storage and powerful PC software all makes YS6010 ideal for color analysis within R&D and laboratory environments.

1-1P504105Z55D[1].jpg

Features-3NH YS6010 benchtop grating spectrophotometer

1, High configuration of hardware: 7 inches TFT Color Capacitive Touch-screen Display; Concave Grating.

2, Double Array 256 Image Element CMOS Sensor; Long life-span stable LED, UV LED.

3, With reflective and transmissive spectrum, accurate Lab value, good to calculate color formula and do precise color transmission.

4, Auto identify measuring aperture. Freely switchable between 4 measuring apertures: φ25.4mm/15mm/8mm/4mm. Users also can customize apertures.

5, Built-in temperature sensor to monitor and compensate the measuring temperature to ensure the measurement more precision.

6, Wavelength range 360nm – 780nm. Built-in 400nm cut off/460nm cut off (only xenon lamp edition), more professional in UV measurement.

7, Independent light source detector, continuously monitor the condition of light sources to ensure the light source reliable.

8, Multiple measurement modes: Quality Management Mode, Sample Mode; Meet more users’ requirement.

9. A variety of optional accessories: Reflection sample holding tool, transmission fixture, micro 4mm aperture transmission test components, instrument inversion test components, applicable to more working conditions;

10, Big capacity data storage, for 20000 pieces test result.

11, Built-in camera locating.

12, More powerful extended functions at the PC software.

Application Industry

YS6010 benchtop spectrophotometer is used to do precise color analysis and transmission in laboratories. It can be widely applied in different industries, such as plastics, elettronica, vernice e inchiostro, stampa, garments, ed075fd1b9d3, carta, auto, medico, cosmetici, cibo, science institutes, laboratories.

Technical Specification-3NH YS6010 benchtop grating spectrophotometer

 

ModelloYS6010 Benchtop Spectrophotometer
Optical GeometryReflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ;
i nostri spettrofotometri offrono il più completo (componente speculare inclusa)/SCE (componente speculare esclusa) ; Include UV / excluded UV light source
Trasmissione: di:0°, de:0° (diffuse illumination: 0° viewing) ;
i nostri spettrofotometri offrono il più completo (componente speculare inclusa)/SCE (componente speculare esclusa) ; Include UV / excluded UV light source;
Foschia(ASTM D1003),
Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7
ApplicazioneIt is used for accurate analysis and transmission of laboratory color. Apply in paints, inchiostri, azoto 0,1-0,15 mpa ossigeno 0,1-0,15 mpa ingresso gas misto ossigeno/azoto, garments, stampa e tintura, printing etc industries for color transfer and quality control.
Integrating Sphere SizeΦ154mm
Fonte di luce360 nm to 780 nm, Combined LED Light, 400nm cut-off light source
Spectrophotometric ModeConcave Grating
Sensore256 Image Element Double Array CMOS Image Sensor
Gamma di lunghezze d'onda360-780nm
Intervallo di lunghezza d'onda10nm
Semiband Width10nm
Measured Reflectance Range0-200%
Misurazione dell'aperturaReflective : Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive : Φ30mm/Φ25mm;
Nota: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position
Specular Componentriflettanza: i nostri spettrofotometri offrono il più completo&SCE / Trasmissione: i nostri spettrofotometri offrono il più completo&SCE
Spazio coloreLABORATORIO CIE,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,Collegati all'app del dispositivo mobile per espandere più funzioni,βxy,DIN Lab99
Formula di differenza di coloreΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (cacciatore),
Other Colorimetric IndexWI (ASTM E313, CIE / ISO, AATCC, cacciatore),
YI (ASTM D1925, ASMA 313),
TI (ASTM E313, CIE / ISO),
MI (Indice di metamerismo),
Staining Fastness, Collegati all'app del dispositivo mobile per espandere più funzioni, Color Strength, i nostri spettrofotometri offrono il più completo,
8° Glossiness,Gardner Index, Pt-Co Index, 555 Index, Foschia(ASTM D1003)
Observer Angle2°/10°
IlluminanteD65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12
Displayed DataSpectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, Risultato PASS/FAIL, Compensazione del colore
Misurare il tempoAbout 2.4s (Measure SCI & SCE about 5s)
RipetibilitàSpectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: entro 0.04%)
U30,U35,DLF:Φ25.4mm/SCI, U30,U35,DLF 0.02 ( Quando viene misurata una piastra di calibrazione del bianco 30 volte a 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: entro 0.04%)
U30,U35,DLF:Φ25.4mm/SCI, U30,U35,DLF 0.03 ( Quando viene misurata una piastra di calibrazione del bianco 30 volte a 5 second intervals after white calibration)
Inter-instrument ErrorΦ25.4mm/SCI, Within ΔE*ab 0.15
(Media per 12 Piastrelle a colori BCRA Serie II)
DimensioneL*W*H=370x300x200mm
PesoApprox. 9.6riflettività di scissione della luce
EnergiaAC 24V, 3A Power adapter power supply
Illuminant Life Span5 anni, più di 3 million times measurements
Schermo7-inch TFT color LCD, Touchscreen capacitivo
Data PortUSB & Print serial port
Archivio datiStandard 2000 Pcs, Campione 20000 Pcs
LinguaSimplified Chinese, Traditional Chinese, English,
Operating Environment0~40℃, 0~85%RH (no condensing), Altitude < 2000m
Storage Environment-20~ 50 ℃, 0~85%RH (no condensing)
Accessorio standardAdattatore di alimentazione, User Guide, CD Disk(PC Software), cavo USB, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Porta campioni, 25.4 caliber, 8 caliber, 4 caliber
Accessorio opzionaleMicro-printer, Transmissive Test Component, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components
AppuntiLe specifiche sono soggette a modifiche senza preavviso.

_mg_0339.jpg_mg_0368.jpg_mg_0386.jpg

Contattaci