YL4560 Non- spettrofotometro da banco a contatto

YL4560 Non- spettrofotometro da banco a contatto

Categorie:

  • Descrizione
  • Inchiesta

Introduction-3nh YL4560 Non- contact benchtop spectrophotometer ISO7724-1,ASTM E1164

YL4560 spectrophotometer is a color measuring instrument with 45/0 optical geometry(45 illuminazione ad anello, visione verticale), to achieve precise non-contact measurement between the measuring probe and the sample like liquids, sauces, powders, eccetera, which is developed by 3nh independently with independent intellectual property.YL4560 non-contact benchtop spectrophotometer can be applied for accurate color analysis and transmission in laboratories and R & D industries; it can also be used for accurate color measurement and quality control of automated production lines; it is widely used in cosmetics, fruits and vegetables, food hygiene, plastic electronics, vernice e inchiostro, stampa, ceramics and other industries, and also for fluorescence sample measurement. Its unique innovative design can not only provide non-contact measurement scheme directly from the production line, but also ensure stable and high-precision measurement results.

YL4560 non-contact spectrophotometer will not touch the sample in the measurement process, to prevent damage to the sample, but also to avoid cross contamination.

PRODUCT FEATURES-3nh YL4560 Non- contact benchtop spectrophotometer ISO7724-1,ASTM E1164

1. non-contact, 45 / 0 geometric optical structure to measure the reflectance and chromaticity of objects;

2. The movable measuring head moves up and down according to the actual height of the measured object;

3. Large touch screen measurement interface, real-time display of measurement data, to realize more measurement functions;

4. Multiple measurement modes (sample, controllo di qualità, continuous statistical mode) can be selected to meet the personalized needs.

APPLICATION INDUSTRY-3nh YL4560 Non- contact benchtop spectrophotometer ISO7724-1,ASTM E1164

45/0 non- contact benchtop spectrophotometer can achieve precise non- contact measurement between the measuring probe and the sample like liquids, sauces, powders, eccetera. It can be applied for accurate color analysis and transmission In laboratories and R & D industries; It can also be used for accurate color measurement and quality control of automated production lines; It is widely used in cosmetics, fruits and vegetables, food hygiene, plastic electronics, vernice e inchiostro, stampa, ceramics and other industries, and also for fluorescence sample measurement.

Specifica

ModelloYL4560
Optical Geometry45/0 metodo(45 illuminazione ad anello, visione verticale);Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7,GB 2893,GB/T 18833
Caratteristiche45/0 non- contact benchtop spectrophotometer can achieve precise non- contact measurement between the measuring probe and the sample like liquids, sauces, powders, eccetera. It can be applied for accurate color analysis and transmission In laboratories and R & D industries; It can also be used for accurate color measurement and quality control of automated production lines; It is widely used in cosmetics, fruits and vegetables, food hygiene, plastic electronics, vernice e inchiostro, stampa, ceramics and other industries, and also for fluorescence sample measurement.
Fonte di luceFull spectrum LED light,UV light
Spectrophotometric ModeConcave Grating
Sensore256 Image Element Double Array CMOS Image Sensor
Gamma di lunghezze d'onda400~700nm/10nm output
U30,U35,DLF0~200%
Misurazione dell'aperturaΦ20mm(can be customized <20mm)
Non-contact Distance7.5mm
Sample Height0~150mm
Distance Adjustment MethodManual adjustment and automatic adjustment (test height can be stored)
Modalità di misurazioneSample mode/QC Mode/Continuous statistics mode
Locating MethodCamera Locating
Spazio coloreLABORATORIO CIE,XYZ,Yxy,LCh,CIE LUV,HunterLAB
Formula di differenza di coloreE*ab,E*uv,ΔE*94,ΔE*cmc(2:1),E*cmc(1:1),ΔE*00,ΔE(cacciatore)
Other Colorimetric IndexWI(ASTM E313, CIE/ISO,AATCC,cacciatore),YI(ASTM D1925, ASTM 313),TI(ASTM E313, CIE/ISO), Metamerism Index MI,Staining Fastness,Collegati all'app del dispositivo mobile per espandere più funzioni,Color Strength, i nostri spettrofotometri offrono il più completo
Observer Angle2°/10°
IlluminanteD65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30)
Displayed DataSpectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, Chromaticity Graph, Simulazione del colore, Risultato PASS/FAIL, Compensazione del colore
Misurare il tempoAbout 1.5s
Archivio datiSample mode + QC mode: 40,000; Continuous statistics mode: 10,000
RipetibilitàSpectral reflectance: Standard deviation within 0.08%
U30,U35,DLF: Within ΔE*ab 0.03 (Quando viene misurata una piastra di calibrazione del bianco 30 volte a 5 second intervals after white calibration)
Inter-instrument ErrorWithin ΔE*ab 0.2(Media per 12 Piastrelle a colori BCRA Serie II)
Measurement ModeSingle Measurement, Average Measurement(2 ~ 99 volte)
Dimensione330*250*370mm
PesoDi 10 riflettività di scissione della luce
I coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del pazienteDC 24V, 3A Power Adapter
Illuminant Life Span5 anni, più di 3 million times measurements
Schermo7″ TFT Capacitive Screen-touch Display
Data PortUSB/RS-232,Bluetooth®4.0
LinguaSimplified Chinese,Traditional Chinese,English
Working EnvironmentI coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del paziente: 0~40℃; I coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del paziente: 0~85% (No Condensation); Altitude < 2000m
Storage EnvironmentI coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del paziente: -20~ 50 ℃; I coefficienti di attrito dei cateteri e dei tubi di alimentazione nasale contro la pelle umana influenzano direttamente la sensazione di benessere del paziente: 0~85% (No Condensation)
Accessorio standardAdattatore di alimentazione, Manuale d'uso, cavo USB, Standard Calibration Board, Black Calibration Cavity,
AppuntiLe specifiche sono soggette a modifiche senza preavviso.